Purging quality

Cycles of concentration Blowdown/purge rate Power cost analysis Drift loss requirement Local authority requirements Discharge qualities Stmctural specifications Pack specifications... [Pg.539]

Hydrogen Hydrogen recovery was the first large commercial membrane gas separation. Polysulfone fiber membranes became available in 1980 at a time when H2 needs were rising, and these novel membranes quickly came to dominate the market. Apphcations include recovery of H2 from ammonia purge gas, and extraction of H2 from petroleum cracking streams. Hydrogen once diverted to low-quality fuel use is now recovered to become ammonia, or is used to desulfurize fuel, etc. H2 is the fast gas. [Pg.57]

Finally, it is very difficult to keep standard solutions for monitoring or recalibration purposes. Control batches should be purged and kept with a dry, inert gas. As long as results are reproduced, the system is considered to be in calibration. The relatively long extraction times usually prohibit the use of these methods for quality control analysis applications in a plastics manufacturing plant. [Pg.59]

Solute-free liquid at a volumetric flow rate Q is used to purge off quality solute from a stirred tank of volume V. Show that if three... [Pg.339]

The airborne monitoring program concentrated on the measurement of ozone to provide supplementary air quality data for various altitudes over the fixed sites. The airborne measurements were conducted in a C-45 aircraft that carried a solid-face chemiluminescent ozone monitor. The ozone meter was cycled every 2 min to provide calibration, purge, measurement, and purge at equal intervals. The sparseness of the airborne data precluded... [Pg.149]

It is important to perform a data capture operation for electronic data as soon as possible to maximize the quantity and quality of such information. For example, one investigator had to download the data within the preset file purge time of eight hours. The programmer was on vacation and there was no documentation available on the program. Even when computer specialists are available, this may be a difficult task because computer specialists do not frequently encounter the questions asked by investigators, f f there is a of loss of electric power, information may be accessible for a limited period due to battery backup for volatile memory. (Email should also be considered as electronic evidence.)... [Pg.135]

While polycarbonate has the desirable qualities as the basic material for information storage, it also has some debits. First, polycarbonate is relatively expensive in comparison with many polymers. Its superior combination of properties and ability for a large cost markup allows it to be an economically feasible material for specific commercial uses. Second, the polar backbone is susceptible to long-term hydrolysis so that water must be ruthlessly purged. The drying process, generally 4 h, is often achieved by placement of polycarbonate chips in an oven at 120°C with a dew point of — 18°C. [Pg.101]

Total dissolved solids (TDS) levels in purge water have posed water quality issues, especially at refineries fhaf discharge into small or impacted bodies of water. These TDS issues have lead to significant permit delays and disposal cost issues. [Pg.304]

The reflectance system also provides a test of the effectiveness of purging prior to the 600°C/He volatilization of organic carbon. Residual O2 at 600°C will oxidize elemental carbon and produce an increase in the reflectance of the filter. In the e-vent that such an increase is observed, the sample would be rerun, and if this behaviour persists, the system would be checked for leaks or other malfunctions. Thus, the reflectance system plays an important quality assurance role in the analysis. [Pg.226]

Meanwhile, because the ARO system is completely automated and simple to operate, the Plater can concentrate on plating production. There is a simple switch with "Auto" and "Service" positions. In "Auto" position, the ARO microprocessor automatically monitors all remote rinse and internal sensors and initiates ARO processing whenever the fir.al rinse exceeds the operator s preset rinse quality standard. In the "Service" position, the ARO system purges itself and depressurizes to allow the operator to service the rinse tanks or the ARO system. [Pg.254]

E. Control chart. Volatile compounds in human blood serum were measured by purge and trap gas chromatography/mass spectrometry. For quality control, serum was periodically spiked with a constant amount of 1,2-dichlorobenzene and the concentration (ng/g = ppb) was measured. Find the mean and standard deviation for the following spike data and prepare a control chart. State whether or not the observations (Obs.) meet each of the criteria for stability of a control chart. [Pg.92]


See other pages where Purging quality is mentioned: [Pg.553]    [Pg.574]    [Pg.6]    [Pg.8826]    [Pg.553]    [Pg.574]    [Pg.6]    [Pg.8826]    [Pg.294]    [Pg.1540]    [Pg.1543]    [Pg.1544]    [Pg.80]    [Pg.158]    [Pg.248]    [Pg.190]    [Pg.296]    [Pg.804]    [Pg.288]    [Pg.575]    [Pg.50]    [Pg.51]    [Pg.52]    [Pg.53]    [Pg.245]    [Pg.33]    [Pg.16]    [Pg.955]    [Pg.396]    [Pg.502]    [Pg.299]    [Pg.56]    [Pg.61]    [Pg.9]    [Pg.168]    [Pg.527]    [Pg.67]    [Pg.533]    [Pg.57]    [Pg.128]    [Pg.561]   