DP Speed Factor. Pumping-speed efficiency depends on trap, valve, and system design. For gases having velocities close to the molecular velocity of the DP top jet, system-area utilization factors of 0.24 are the maximum that can be anticipated eg, less than one quarter of the molecules entering the system can be pumped away where the entrance area is the same as the cross-sectional area above the top jet (see Fig. 4). The system speed factor can be quoted together with the rate of contamination from the pump set. Utilization factors of <0.1 for N2 are common. [Pg.370]

The rate of contamination from the pump set is <10 molecule/(m -s) for molecular weights >44 (23). This is the maximum contamination rate for routine service for a weU-designed system that is used constantly and subject to automatic Hquid-nitrogen filling and routine maintenance. [Pg.370]

Windmills (induction generators) as an unconventional energy source, vertical hollow shaft motors and submersible pump sets, selection of belts for transmission of load, the phenomenon of shaft currents are discussed. [Pg.989]

Corrective Action Check operation of feed pump. Check pump settings. [Pg.315]

Figure 2. Schematic representation of the reactor system computer-controlled pumps (PI, P2) pump controllers (fc) reactor (CSTR) reception vessel valves (S1-S4) monomer and initiator storage vessels (Tl, T2). (a) Digital input from GPC injection valve (b) analogue output from GPC (c, d) digital outputs to recorder chart drive and event marker (e, f) analogue outputs for pump set-point adjustment (g,h) reactor feeds (i) reactor output (j-m) digital outputs to reception system valves (n) manual sampling of products by GPC,... Figure 2. Schematic representation of the reactor system computer-controlled pumps (PI, P2) pump controllers (fc) reactor (CSTR) reception vessel valves (S1-S4) monomer and initiator storage vessels (Tl, T2). (a) Digital input from GPC injection valve (b) analogue output from GPC (c, d) digital outputs to recorder chart drive and event marker (e, f) analogue outputs for pump set-point adjustment (g,h) reactor feeds (i) reactor output (j-m) digital outputs to reception system valves (n) manual sampling of products by GPC,...
It is clear from Figure 1 that in the first experiment (Figure la) f and f. were oscillated in opposition of phase with maximum possible amplitude of the pump setting. In the second experiment (Figure lb) nearly rectangular waves were used for... [Pg.261]

The traditional arrangement of simple spherical glassware and Isomantles with full-power on-off controllers monitored by mercury thermometers, would still be widely recognised. So too would be the plug-shot piston pumps set up and monitored by use of measuring cylinders. Although tried and tested this hardware system requires constant attention by a skilled lab. technician to achieve control and reproducibility of even the first-order process parameters manual data collection is hardly feasible at better than 10-15 minute intervals. [Pg.438]

The valve between condenser and vacuum pump set (Fig. 1.65 and Fig. 1.66) is closed until the desired total pressure is built up. If the controlled pressure is exceeded, the valve opens. [Pg.75]

Fig. 2.28. Schema of a vacuum pump set, designed for a production freeze drying plant. Fig. 2.28. Schema of a vacuum pump set, designed for a production freeze drying plant.
Vacuum pumping set Two stages, with gasballast, in max. 15 min down to 0.02 mbar7 Two stages, with gasballast in max. 10 min >0.1 mbar7... [Pg.175]

The chosen Tice has been reached in the pilot plant at pc mbar ( 5 % and at 7+ = -10 °C. Note In a freeze drying plant with different dimensions and different number of vials pc will be slightly different to achieve the desired Tjce. Therefore pc must bee modified accordingly. In the pilot plant, a change of pc to 1.1 pc ( 5 % increases Tkc by 0.5 °C. In the pilot plant, pc has been controlled by closing the valve between the condenser and the vacuum pump set. [Pg.259]

In vivo microdialysis is based on the principle of dialysis, the process whereby concentration gradients drive the movement of small molecules and water through a semipermeable membrane. In vivo microdialysis involves the insertion of a small semipermeable membrane into a specific region of a living animal, such as the brain. The assembly that contains this semipermeable membrane is called a probe, which is composed of an inlet and an outlet compartment surrounded by a semipermeable membrane (see O Figure 9-1). Using a microinfusion pump set at a low flow rate (0.2-3 /rL/min), an aqueous solution known as the perfusate is pumped into the inlet compartment of the microdialysis probe. Ideally, the... [Pg.222]

A five-cell stack (with a structure identical with that of the 30-cell stack) and a column of Drierite (anhydrous CaSO (W.A. Hammond Dryerite) used for trapping water vapor in the stack cathode exhaust stream were placed inside a convection oven set at the stack operating temperature. A T-valve was used to separate the water vapor and liquid water by gravity. The liquid water was directed to the outside of the oven with a peristaltic pump set at a flow rate of 1 mLmin , which was slightly higher than the flux of liquid water from the stack cathode exit but significantly lower than the cathode feed rate. The liquid water thus separated from the stack cathode exhaust stream was collected vdth a conical beaker placed... [Pg.52]

Comparatively, then, a pump set consisting of a Roots pump, condenser, and backing pump, which can transport 100 kg/h of vapor and 18 kg/h of air at an inlet pressure of 50 mbar, has a power requirement of 4 -10 kW (depending on the quantity of air involved). A steam ejector pump of the same performance requires about 60 kW without altering the quantity of air involved. [Pg.62]

Normally, Roots pumps are not as economical as gas ballast pumps for continuous operation at pressures above 40 mbar. With very large pump sets, which work with very specialized gear ratios and are provided with bypass lines, however, the specific energy consumption is indeed more favorable. If Roots pumps are installed to pump vapors, as in the case of gas ballast pumps, a chart can be given that includes all possible cases (see Fig. 2.74). [Pg.63]

The partial flow concept is usually used in making the connection of a helium leak detector to vacuum systems with multi-stage vacuum pump sets. When considering where to best make the connection, it must be kept in mind that these are usually small, portable units which have only a low pumping speed at the connection flange (often less than 1 l/s). This makes it all the more important to estimate - based on the partial flow ratio to be... [Pg.121]

This is a three-stage pump set with the corresponding accessories. [Pg.503]

The powder is spread on cotton muslin stretched over wooden frames and placed on the shelves. The drier is then closed and the vacuum pump set in motion. The pump usually operates a pressure of 100-150 mm Hg. When the pressure becomes steady, the screws clamping the lids are released, but the lids continue to adhere hermetically to the drier, owing to the reduced pressure created inside. As a safety precaution the driers work in this manner until drying has been completed. Thus should ignition occur the lids are freely detached. This prevents thepowder from burning in a confined space, and exploding, and so destroying the drier. The capacity of the... [Pg.612]


See other pages where Pumps setting is mentioned: [Pg.170]    [Pg.175]    [Pg.193]    [Pg.193]    [Pg.336]    [Pg.336]    [Pg.207]    [Pg.334]    [Pg.516]    [Pg.207]    [Pg.367]    [Pg.216]    [Pg.420]    [Pg.172]    [Pg.182]    [Pg.193]    [Pg.255]    [Pg.262]    [Pg.230]    [Pg.69]    [Pg.59]    [Pg.18]    [Pg.49]    [Pg.135]    [Pg.135]    [Pg.136]    [Pg.102]    [Pg.498]    [Pg.503]    [Pg.599]    [Pg.36]    [Pg.342]   