Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Process analysis solid analyzers

As a part of the electrodes used in galvanic cells, the role of direct (internal) contact is to facilitate communication between the meter and the electrochemical cell. This is usually sohd contact (SC) and is referred to by names such as solid contact irai-selective electrodes (SC ISEs) or sohd contact reference electrodes (SC REs). The main reason for introducing sohd contact into indicator/working or reference electrodes is to eliminate their watery compartments, often called internal solution. This soluticm can be an obstacle in many appHcations where there are restrictive maintenance and/or service demands (e.g., in clinical chemistry), there is contamination of the sample by a leakage of the internal soluhon (e.g., in cellular biology), there is a need for other than a vertical position (e.g., in industrial process analysis), or specific reference electrode shapes (e.g., in disposable chnical analyzers) are required. [Pg.279]

Of all the techniques that have been developed to analyze surfaces. Auger electron spectroscopy has had the most widespread application. In the field of materials science, it has joined such analytical methods as X-ray diffraction and transmission electron microscopy as a staple of any well-equipped laboratory. It is used in chemistry and materials science to study the composition of solid surfaces and the chemical states of atoms and molecules on those surfaces. Chemists and physicists study the basic Auger transition to help learn about electronic processes in solids. Those interested in developing electronic equipment have been concerned with providing spectrometers with ever-decreasing incident beam diameters that will allow the chemical analysis of a surface on a microscopic scale. It is hoped that this article plus the... [Pg.63]

Questions of the analytic control of maintenance of the bivalent metals cations to their joint presence in materials of diverse fixing always were actual. A simultaneous presence in their composition of two cations with like descriptions makes analysis by sufficiently complicated process. Determination of composition still more complicates, if analyzed object is a solid solution, in which side by side with pair of cations (for example, Mg " -Co ", Mn -Co, Zn -Co ) attends diphosphate anion. Their analysis demands for individual approach to working of methods using to each concrete cations pair. [Pg.182]

The composition of steels or other metals is commonly analyzed by emission or X-ray spectrometry during and after the production process. Both methods have to be calibrated by solid samples. These are either exactly analyzed samples taken from the same process or synthetic melted mixtures of the matrix with added accompanying elements (RMs). Available CRMs are then used to control the slope of the calibration function. Today, available RMs and CRMs are increasingly and exclusively used in spectral laboratories as the chemical analysis became much restricted and typical control laboratories were totally closed (Slickers 1993). [Pg.142]

Vol. 66 Solid Phase Biochemistry Analytical and Synthetic Aspects. Edited by William H. Scouten Vol. 67 An Introduction to Photoelectron Spectroscopy. By Pradip K. Ghosh Vol. 68 Room Temperature Phosphorimetry for Chemical Analysis. By Tuan Vo-Dinh Vol. 69 Potentiometry and Potentiometric Titrations. By E. P. Serjeant Vol. 70 Design and Application of Process Analyzer Systems. By Paul E. Mix Vol. 71 Analysis of Organic and Biological Surfaces. Edited by Patrick Echlin Vol. 72 Small Bore Liquid Chromatography Columns Their Properties and Uses. Edited by Raymond P.W. Scott... [Pg.652]

In HPLC, the mobile phase is a liquid in which the sample must be soluble, and detection is most often accomplished by ultraviolet (UV) absorption. It is generally a slower process than GC however, its advantage is that the compounds to be separated are not limited by their boiling point, although low-boiling compounds are almost never separated by HPLC. Solid mixtures, as long as they are soluble in the mobile phase, can be analyzed by HPLC, whereas the solids that are typically encountered in soil analysis are not usually volatile enough to analyze via GC. [Pg.281]

CF-IRMS provides reliable data on micromoles or even nanomoles of sample without the need for cryogenic concentration because more of the sample enters the ion source than in DI-IRMS. CF-IRMS instruments accept solid, liquid, or gaseous samples such as leaves, soil, algae, or soil gas, and process 100-125 samples per day. Automated sample preparation and analysis takes 3-10 min per sample. The performance of CF-IRMS systems is largely determined by the sample preparation technology. A variety of inlet and preparation systems is available, including GC combustion (GC/C), elemental analyzer, trace gas pre-concentrator and other. The novel... [Pg.166]

It is necessary to consider a number of equilibrium reactions in an analysis of a hydrometallurgical process. These include complexing reactions that occur in solution as well as solubility reactions that define equilibria for the dissolution and precipitation of solid phases. As an example, in analyzing the precipitation of iron compounds from sulfuric acid leach solutions, McAndrew, et al. (11) consider up to 32 hydroxyl and sulfate complexing reactions and 13 precipitation reactions. Within a restricted pH range only a few of these equilibria are relevant and need to be considered. Nevertheless, equilibrium constants for the relevant reactions must be known. Furthermore, since most processes operate at elevated temperatures, it is essential that these parameters be known over a range of temperatures. The availability of this information is discussed below. [Pg.627]

In order to gain some information about the fundamentals of the hydrothermal carbonization process, the hydrothermal carbonization of different carbohydrates and carbohydrate products was examined [12, 13]. For instance, hydrothermal carbons synthesized from diverse biomass (glucose, xylose, maltose, sucrose, amylopectin, starch) and biomass derivatives (HMF and furfural) were treated under hydrothermal conditions at 180 °C and were analyzed with respect to their chemical and morphological structures by SEM,13 C solid-state NMR and elemental analysis. This was combined with GC-MS experiments on residual liquor solutions to analyze side products... [Pg.202]


See other pages where Process analysis solid analyzers is mentioned: [Pg.144]    [Pg.305]    [Pg.280]    [Pg.326]    [Pg.320]    [Pg.141]    [Pg.320]    [Pg.3883]    [Pg.281]    [Pg.755]    [Pg.210]    [Pg.471]    [Pg.198]    [Pg.180]    [Pg.561]    [Pg.587]    [Pg.241]    [Pg.348]    [Pg.330]    [Pg.577]    [Pg.186]    [Pg.513]    [Pg.2]    [Pg.156]    [Pg.300]    [Pg.618]    [Pg.485]    [Pg.204]    [Pg.5]    [Pg.270]    [Pg.137]    [Pg.19]    [Pg.64]    [Pg.383]    [Pg.111]    [Pg.128]    [Pg.265]    [Pg.222]    [Pg.355]   
See also in sourсe #XX -- [ Pg.747 , Pg.748 , Pg.749 ]




SEARCH



Process analysis

Process analysis processes

Process analyzers

Processing analysis

Solid analyses

Solid process

Solids processing

© 2024 chempedia.info