Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Probe amplitude

We start by expanding the polarization to first order in the probe amplitude... [Pg.355]

The amplitude (k/kj T qko) may be considered as a probe amplitude for the momentum-space structure amplitude (q/ 0). It is the structure amplitude that is essentially probed by the reaction. Increasingly-refined forms may be used for the probe amplitude. The plane-wave impulse approximation is... [Pg.290]

The existence of a common momentum profile for the manifold a confirms the weak-coupling binary-encounter approximation. Within these approximations we must make further approximations to calculate differential cross sections. For the probe amplitude of (11.1) we may make, for example, the distorted-wave impulse approximation (11.3). This enables us to identify a normalised experimental orbital for the manifold. If normalised experimental orbitals are used to calculate the differential cross sections for two different manifolds within experimental error this confirms the whole approximation to this stage. An orbital approximation for the target structure (such as Hartree—Fock or Dirac—Fock) is confirmed if the experimental orbital energy agrees with the calculated orbital energy and if it correctly predicts differential cross sections. [Pg.294]

Fig. 11.4 illustrates the momentum profiles of the other ion states observed in a later experiment with better energy resolution than that of fig. 11.2. All these states have momentum profiles of essentially the same shape. They are thus identified as states of the same orbital manifold, for which the experiment obeys the criterion for the validity of the weak-coupling binary-encounter approximation. Details of electron momentum spectroscopy depend on the approximation adopted for the probe amplitude of (11.1). The 3s Hartree—Fock momentum profiles in the plane-wave impulse approximation identify the 3s manifold. However, the approximation underestimates the high-momentum profile. [Pg.296]

In the frame of CSTPM, the following dynamics parameters of the cascade system components can be experimentally measured the spin label rotation correlation time and spin relaxation parameters, the fluorescence and phosphorescence polarization correlation times, the singlet and triplet state quenching rate constants, the rate constant of photoisomerization, and the rate constant of the triplet-triplet energy transfer. This set of parameters is a cumulative characteristic of the dynamic state of biomembranes in the wide range of the probes amplitude and characteristic time. [Pg.300]

Automatic amplitude compensation Ensures uniform probe amplitude regardless of the var3ung loading conditions encovuitered during the processing cycle. [Pg.828]

During the inspection of an unknown object its surface is scanned by the probe and ultrasonic spectra are acquired for many discrete points. Disbond detection is performed by the operator looking at some simple features of the acquired spectra, such as center frequency and amplitude of the highest peak in a pre-selected frequency range. This means that the operator has to perform spectrum classification based on primitive features extracted by the instrument. [Pg.109]

The instrument uses a sinusoidal driver. The spectrum is very clean as we use a 14 bits signal generator. The probe signal is modulated in amplitude and phase by a defect signal. The demodulation is intended to extract the cartesian values X and Y of this modulation. [Pg.280]

An important parameter for the probe development is the amplitude of the exciter current, because of its influence on the diameter of the wire... [Pg.316]

By variation of ceramic volume fraction and selection of the best fitting PZT material we can as well adjust the dielectric constant of the piezocomposite within a wide range. Therefore, we can choose the best piezocomposite material for each probe type to get optimum pulse form and amplitude. [Pg.708]

A corresponding composite probe with the same frequency and crystal size, however, detects the test flaw much better the echo has a 12 dB higher amplitude (see Fig. 4) and in addition, the noise level is much lower, resulting in an improved signal to noise ratio. This effect is especially observed at high sound attenuation. However, in materials with low attenuation or in case of shorter sound paths the standard probe yields a comparable good signal to noise ratio. [Pg.709]

Another example shows a 4 MHz longitudinal wave probe WSY70-4 normally used for testing of coarse grained austenitic material. In this application a high pulse amplitude is... [Pg.709]

For immersion probes we also get similar improvements using piezocomposite transducers as demonstrated by the third example. In Fig. 8 we compare pulse form and frequency spectrum for a 2 MHz probe Z2K with 10 mm transducer diameter. The echo of the composite probe has 11 dB more amplitude and is clearly shorter than for the old design, also indicated by the increase in bandwidth from 45 to 76 %. [Pg.710]

Composite transducers will replace conventional transducers in applications where the improvement of test sensitivity, signal to noise ratio and axial resolution are mandatory. It must nevertheless also be noted in connection with the broadband feature that though composite probes have a specified nominal frequency, the echo signals allow no echo amplitude... [Pg.711]

Block 4 a high-voltage generator of the probe pulse, the output value of the amplitude is from 100 to 400V, the duration of the pulse is from 15 to 300 ns. [Pg.731]

The status bar displays information about the current status of the acquisition system the position of each of the four axes of the probe position monitor the maximum amplitude of the signal within the gate for both the coupling channel and the signal (flaw detection) channel and the current operating mode of the system, which may be record-... [Pg.768]

The exact position of reflectors within the weld volume is calculated by means of the known probe position plus weld geometry and transferred to a true-to-scale representation of the weld (top view and side view). Repeated scanning of the same zone only overwrites the stored indications in cases where they reach a higher echo amplitude. The scanning movement of the probe is recorded in the sketch at the top, however, only if the coupling is adequate and the probe is situated within the permissible rotation angle. [Pg.777]

The properties of a single crystal creeping wave probe The a single crystal creeping wave probe is suitable for testing various artificial defects such as surface cracks, FBH, columned hole and SDH etc. and its distance amplitude cruve is shown in Fig.6... [Pg.809]

With the reference block method the distance law of a model reflector is established experimentally prior to each ultrasonic test. The reference reflectors, mostly bore holes, are drilled into the reference block at different distances, e.g. ASME block. Prior to the test, the reference reflectors are scanned, and their maximised echo amplitudes are marked on the screen of the flaw detector. Finally all amplitude points are connected by a curve. This Distance Amplitude Curve (DAC) serves as the registration level and exactly shows the amplitude-over-distance behaviour" of the reference reflector for the probe in use. Also the individual characteristics of the material are automatically considered. However, this curve may only be applied for defect evaluation, in case the reference block and the test object are made of the same material and have undergone the same heat treatment. As with the DGS-Method, the value of any defect evaluation does not consider the shape and orientation of the defect. The reference block method is safe and easy to apply, and the operator need not to have a deep understanding about the theory of distance laws. [Pg.813]

Once the probe is set into the target, the acquisitions consist of the peak to peak amplitude, the time of flight and the frequency response of the back-reflected echo. [Pg.821]

CCF dependences on the -factor of loaded probe vibrators are shown in Fig.4. For s(l) pulses growth of 2 factor increase CCF maximum amplitude and selectivity. In this case the higher the Q, the longer the pulse duration and the more its periods contribute to the processing. F or q(t) pulses rising of g-factor decrease CCF maximum amplitudes and reduce the selectivity. As q(l) pulse consists of a few first periods only its maximum amplitude depends on Q. the higher the Q, the lower the final pulse amplitude, and therefore, CCF amplitude and selectivity. [Pg.830]

To increase the sensitivity, direction of amplitude variation of probe output signal in defective area must coincide with the one after CCF processing. If the defect decreases the probe signal (single contact probe) A((/should be set Ai// = 0, in the opposite case (twin contact probe) it should be set Aif/= n. So the instrument should be supplied with a device to adjust A((/ and to sustain it constant. [Pg.832]

The Evaluation system is a Windows based open system through DLL, Dynamic Link Library, which provides great flexibility in evaluation and presentation of data. It also makes it possible to customise evaluation and images for special applications The time gates can be set after testing and there is a 256 colour range for amplitude. The software include FFT -facilities which enables measurements on used probes for parameters such as center frequenzy and bandwidth. [Pg.864]

At this stage, we do not know how much of 2p.j, 3p.j, 4p.j,. .. np.j this wavefunction contains. To probe this question another subsequent measurement of the energy (corresponding to the H operator) could be made. Doing so would allow the amplitudes in the expansion of the above f"= P.i... [Pg.48]


See other pages where Probe amplitude is mentioned: [Pg.556]    [Pg.50]    [Pg.295]    [Pg.556]    [Pg.50]    [Pg.295]    [Pg.163]    [Pg.226]    [Pg.227]    [Pg.315]    [Pg.316]    [Pg.708]    [Pg.710]    [Pg.767]    [Pg.818]    [Pg.827]    [Pg.845]    [Pg.1015]    [Pg.243]    [Pg.1243]    [Pg.1349]    [Pg.1538]    [Pg.1629]    [Pg.1753]    [Pg.2754]    [Pg.100]    [Pg.124]    [Pg.130]   
See also in sourсe #XX -- [ Pg.290 ]




SEARCH



© 2024 chempedia.info