Pressure drop sieve plates

Example 11 Pressure Drop Sieve Plate For the conditions of Example 10, estimate the pressure drop for flow across one plate. The thickness of the plate metal is 2 mm and the hole diameter is 4.8 mm. The superficial F-factor is 2.08 m/s(kg/m ) . [Pg.1379]

Example 11 Pressure Drop, Sieve Plate For the conditions of... [Pg.1202]

Example 18.6. A sieve-plate column operating at atmospheric pressure is to produce nearly pure methanol from an aqueous feed containing 40 mole percent methanol. The distillate product rate is 5800 kg/h. (a) For a reflux ratio of 3.5 and a plate spacing of 18 in., calculate the allowable vapor velocity and the column diameter. b) Calculate the pressure drop per plate if each sieve tray is in, thick with j-in, holes on a -in. triangular spacing and a weir height of 2 in. (c) What is the froth height in the downcomer ... [Pg.566]

A sieve-tray column with 15 plates is used to prepare 99 percent methanol from a feed containing 40 percent methanol and 60 percent water (mole percent). The plates have 8 percent open area, in. holes, and 2-in. weirs with segmental downcomers, (a) If the column is operated at atmospheric pressure, estimate the flooding limit based on conditions at the top of the column. What is the F factor and the pressure drop per plate at this limit (Z>) For the flow rate calculated in part (a) determine the F factor and the pressure drop per plate near the bottom of the column. Which section of the column will flood first as the vapor rate is increased ... [Pg.587]

Sieve Plates. The conventional sieve or perforated plate is inexpensive and the simplest of the devices normally used. The contacting orifices in the conventional sieve plate are holes that measure 1 to 12 mm diameter and exhibit ratios of open area to active area ranging from 1 20 to 1 7. If the open area is too small, the pressure drop across the plate is excessive if the open area is too large, the Hquid weeps or dumps through the holes. [Pg.167]

The plate thickness of bubble-cap and sieve plates is generally estabhshed by mechanical design factors and has little effect on pressure drop. For a sieve plate, however, the plate is an integral component of the vapor-dispersion system, and its thickness is important. [Pg.1375]

FIG. 14-29 Pressure-drop contributions for cross-flow plates, = pressure drop through cap or sieve, equivalent height of plate liquid = height of weir ... [Pg.1376]

Pressure Drop Methods for estimating fluid-dynamic behavior of crossflow plates are analogous, whether the plates be bubble-cap, sieve, or valve. The total pressure drop across a plate is defined by the general equation (see Fig. 14-29)... [Pg.1376]

FIG. 14-32 Aeration factor for pressure drop calculation, sieve plates. [Bolles and Fair, Encyclopedia of Chemical Processing and Design, vols. 16, 86. J. M. McKetta (ed.), Marcel Dekker, New Yoik, J9S2.]... [Pg.1378]

As noted, the weir crest is calculated on an equivalent clear-liquid basis. A more realistic approach is to recognize that in general a froth or spray flows over the outlet weir (settling can occur upstream of the weir if a large calming zone with no dispersers is used). Bennett et al. [AIChE J., 29, 434 (1983)] allowed for froth overflow in a comprehensive study of pressure drop across sieve plates their correlation for residual pressure drop /jf in Eq. (14-87) is represented by Eqs. (14-115) through (14-120) ... [Pg.1378]

A common type of distillation contacting device used in refinery applications is the sieve tray. In the early 50 s and for many years before, the bubble cap tray was the mainstay of the distillation field. A sieve tray consists of a flat plate with regularly spaced holes, normally 1/2 to 1 inch in diameter. Liquid flows horizontally across the tray and into a channel, called a downcomer, which leads to the tray below. The sieve tray exhibits good capacity, excellent efficiency, low pressure drop, and good flexibility i.e., it will operate quite efficiently at tower loadings which are 1/2 to 1/3 of design values. [Pg.85]

Commercial preparations of these supports are available in narrow mesh-range fractions to obtain particles of uniform size the material should be sieved to the desired particle size range and repeatedly water floated to remove fine particles which contribute to excessive pressure drop in the final column. To a good approximation the height equivalent of a theoretical plate is proportional to the average particle diameter so that theoretically the smallest possible particles should be preferred in terms of column efficiency. Decreasing particle size will, however, rapidly increase the gas pressure necessary to achieve flow through the column and in practice the best choice is 80/100 mesh for a... [Pg.238]

The principal factors to consider when comparing the performance of bubble-cap, sieve and valve plates are cost, capacity, operating range, efficiency and pressure drop. [Pg.560]

Pressure drop. The pressure drop over the plates can be an important design consideration, particularly for vacuum columns. The plate pressure drop will depend on the detailed design of the plate but, in general, sieve plates give the lowest pressure drop, followed by valves, with bubble-caps giving the highest. [Pg.561]

The plates may be any of several types, including sieve, bubble-cap, and valve trays. Valve trays constitute multiple self-adjusting orifices that provide nearly constant gas pressure drop over considerable ranges of variation in gas flow. The gas pressure drop that can be taken across a single plate is necessarily limited, so that units designed for high contacting power must use multiple plates. [Pg.42]

When vapor flows through a tray deck, the vapor velocity increases as the vapor flows through the small openings provided by the valve caps, or sieve holes. The energy to increase the vapor velocity comes from the pressure of the flowing vapor. A common example of this is the pressure drop we measure across an orifice plate. If we have a pipeline velocity of 2 ft/s and an orifice plate hole velocity of 40 ft/s, then the energy needed to accelerate the vapor as it flows through the orifice plate comes from the pressure drop of the vapor itself. [Pg.10]

APdry Pressure drop across dry sieve plate. [Pg.283]

APtotai Total pressure drop across sieve-tray plate, s Fraction of open area on sieve plate. [Pg.283]

For sieve trays, the number of kinetic heads equivalent to the total pressure drop through the plate itself is a function of the ratio of the sieve-hole diameter to the tray thickness and the ratio of the hole area per tray to the active area per tray as shown in Fig. 16-5. This pressure drop for a reasonable sieve-tray design is generally in the range of 1 to 3 kinetic heads, and Fig. 16-12 can be used to choose the most reasonable number to use in preliminary designs Designating the number of kinetic heads obtained from Fig. 16-12 as K.H., the pressure drop due to gas flow through the holes for a sieve tray expressed as liquid head is... [Pg.670]

In the current case, slightly more than half of the hydrostatic pressure drop along the phloem is necessary to overcome the resistance of the sieve plate pores. When the end walls are steeply inclined to the axis of the sieve element, the pores of the sieve plate can occupy an area that is greater than the cross section of the sieve tube. This causes Jv in the pores to be less than in the lumen and tends to reduce the resistance to flow in the phloem. [Pg.480]


See other pages where Pressure drop sieve plates is mentioned: [Pg.1348]    [Pg.1171]    [Pg.1352]    [Pg.1348]    [Pg.1171]    [Pg.1352]    [Pg.18]    [Pg.408]    [Pg.409]    [Pg.411]    [Pg.92]    [Pg.327]    [Pg.1346]    [Pg.1375]    [Pg.1376]    [Pg.1439]    [Pg.1441]    [Pg.1594]    [Pg.498]    [Pg.403]    [Pg.183]    [Pg.124]    [Pg.126]    [Pg.45]    [Pg.667]    [Pg.668]    [Pg.734]    [Pg.480]    [Pg.18]    [Pg.408]    [Pg.409]    [Pg.411]   
See also in sourсe #XX -- [ Pg.574 ]

See also in sourсe #XX -- [ Pg.728 ]




SEARCH



Drop plate

Plate pressure drop

Pressure plate

Sieve plate

Sieve plate design pressure drop

Sieve-plate columns pressure drops

© 2024 chempedia.info