Precision chromatography

Finally, other methods are used to obtain simulated distillation by gas phase chromatography for atmospheric or vacuum residues. For these cases, some of the sample components can not elute and an internal standard is added to the sample in order to obtain this quantity with precision. [Pg.23]

Natural gas analysis has considerable economic importance. In fact, commercial contracts increasingly specify not just volume but the calorific or heating value as well. Today the calorific value of a natural gas calculated from its composition obtained by chromatography is recognized as valid. There is therefore a large research effort devoted to increasing the precision of this analysis. [Pg.71]

Thin-layer chromatography (76,77) has been used for the estimation of the amounts of dimer, trimer, and monomer ia methyl esters. Both this method and paper chromatography are characterized by lack of precision (78,79) (see Chromatography). [Pg.116]

There are two main approaches to its solution. Traditional approach is based on preliminary separation of UGC samples to gaseous and liquid phases and their subsequent analyses [1]. This approach is well-developed and it allows obtaining quite precise results being used properly. However, this method is relatively complicated. Multi-stage procedure is a source of potential errors, then, it makes the analyses quite time consuming. More progressive approach is based on the direct analysis of the pressurized UGC samples. In both cases the determination of heavy hydrocarbons (up to C ) is made by capillary gas chromatography. [Pg.184]

The abundance of a trace element is often too small to be accurately quantihed using conventional analytical methods such as ion chromatography or mass spectrometry. It is possible, however, to precisely determine very low concentrations of a constituent by measuring its radioactive decay properties. In order to understand how U-Th series radionuclides can provide such low-level tracer information, a brief review of the basic principles of radioactive decay and the application of these radionuclides as geochronological tools is useful. " The U-Th decay series together consist of 36 radionuclides that are isotopes (same atomic number, Z, different atomic mass, M) of 10 distinct elements (Figure 1). Some of these are very short-lived (tj j 1 -nd are thus not directly useful as marine tracers. It is the other radioisotopes with half-lives greater than 1 day that are most useful and are the focus of this chapter. [Pg.35]

The value of (q) takes into account the precise shape of the pool of stationary phase for a uniform liquid film as in a GC capillary column, q = 2/3. Diffusion in rod shaped and sphere shaped bodies (e.g., paper chromatography and LC) gives q=l/2 and 2/15, respectively [2]. [Pg.255]

The chromatography literature contains a vast amount of dispersion data for all types of chromatography and, in particular, much of the data pertains directly to GC and LC. Unfortunately, almost all the data is unsuitable for validating one particular dispersion equation as opposed to another. There are a number of reasons for this firstly, the necessary supporting data (e.g., diffusivity data for the solutes in the solvents employed as the mobile phase, accurate distribution and/or capacity factor constants (k")) are not available secondly, the accuracy and precision of much of the data are inadequate, largely due to the use of inappropriate apparatus with high extracolumn dispersion. [Pg.315]

Katz et fl/.[l] searched the literature for data that could be used to identify the pertinent dispersion equation for a packed column in liquid chromatography. As a result of the search, no data was found that had been measured with the necessary accuracy and precision and under the sufficiently diverse solute/mobile phase conditions required to meet the second criteria given above. It became obvious that a... [Pg.316]

New templated polymer support materials have been developed for use as re versed-phase packing materials. Pore size and particle size have not usually been precisely controlled by conventional suspension polymerization. A templated polymerization is used to obtain controllable pore size and particle-size distribution. In this technique, hydrophilic monomers and divinylbenzene are formulated and filled into pores in templated silica material, at room temperature. After polymerization, the templated silica material is removed by base hydrolysis. The surface of the polymer may be modified in various ways to obtain the desired functionality. The particles are useful in chromatography, adsorption, and ion exchange and as polymeric supports of catalysts (39,40). [Pg.10]

Determinarion of MW and MWD by SEC using commercial narrow molecular weight distribution polystyrene as calibration standards is an ASTM-D5296 standard method for polystyrene (11). However, no data on precision are included in the 1997 edition of the ASTM method. In the ASTM-D3536 method for gel-permeation chromatography from seven replicates, the M of a polystyrene is 263,000 30,000 (11.4%) for a single determination within the 95% confidence level (12). A relative standard deviation of 3.9% was reported for a cooperative determination of of polystyrene by SEC (7). In another cooperative study, a 11.3% relative standard deviation in M, of polystyrene by GPC was reported (13). [Pg.503]

In this chapter, we will discuss the present status of CHIRBASE and describe the various ways in which two (2D) or three-dimensional (3D) chemical structure queries can be built and submitted to the searching system. In particular, the ability of this information system to locate and display neighboring compounds in which specified molecular fragments or partial structures are attached is one of the most important features because this is precisely the type of query that chemists are inclined to express and interpret the answers. Another aspect of the project has been concerned with the interdisciplinary use of CHIRBASE. We have attempted to produce a series of interactive tools that are designed to help the specialists or novices from different fields who have no particular expertise in chiral chromatography or in searching a chemical database. [Pg.96]

Thin-layer chromatography was also used in an attempt further to purify fractions that had been separated by column or gas chromatography. Rather precise Rf values for several compounds were... [Pg.64]

In many analyses, fhe compound(s) of inferesf are found as par of a complex mixfure and fhe role of fhe chromatographic technique is to provide separation of fhe components of that mixture to allow their identification or quantitative determination. From a qualitative perspective, the main limitation of chromatography in isolation is its inability to provide an unequivocal identification of the components of a mixture even if they can be completely separated from each other. Identification is based on the comparison of the retention characteristics, simplistically the retention time, of an unknown with those of reference materials determined under identical experimental conditions. There are, however, so many compounds in existence that even if the retention characteristics of an unknown and a reference material are, within the limits of experimental error, identical, the analyst cannot say with absolute certainty that the two compounds are the same. Despite a range of chromatographic conditions being available to the analyst, it is not always possible to effect complete separation of all of the components of a mixture and this may prevent the precise and accurate quantitative determination of the analyte(s) of interest. [Pg.20]

Table 5.20 Intra-assay precision and accuracy of the LC-ToF-MS determination of Idoxifene. Reprinted from J. Chromatogr, B, 757, Comparison between liquid chromatography-time-of-flight mass spectrometry and selected-reaction monitoring liquid chromatography-mass spectrometry for quantitative determination of Idoxifene in human plasma , Zhang, H. and Henion, J., 151-159, Copyright (2001), with permission from Elsevier Science... Table 5.20 Intra-assay precision and accuracy of the LC-ToF-MS determination of Idoxifene. Reprinted from J. Chromatogr, B, 757, Comparison between liquid chromatography-time-of-flight mass spectrometry and selected-reaction monitoring liquid chromatography-mass spectrometry for quantitative determination of Idoxifene in human plasma , Zhang, H. and Henion, J., 151-159, Copyright (2001), with permission from Elsevier Science...
The first part of the book consists of a detailed treatment of the fundamentals of thin-layer chromatography, and of measurement techniques and apparatus for the qualitative and quantitative evaluation of thin-layer chromatograms. In situ prechromatographic derivatization techniques used to improve the selectivity of the separation, to increase the sensitivity of detection, and to enhance the precision of the subsequent quantitative analysis are summarized in numerous tables. [Pg.4]

Snyder, L. R., and van der Wal, S. J. Precision of Assays Based on Liquid Chromatography with Prior Solvent Extraction of the Sample, Anal. Chem. 53, 1981, 877-884. [Pg.409]

Eichelberger JW, Kerns EH, Olynyk P, et al. 1983. Precision and accuracy in the determination of organics in water by fused silica capillary column gas chromatography/mass spectrometry and packed column gas chromatography/mass spectrometry. Anal Chem 55 1471-1479. [Pg.284]

The reason for this lies not least in the increasing instrumentalization and delibei automation of all those processes which were earlier particularly subject to eri (Fig. 2). Modem high performance thin-layer chromatography (HPTLC) is no Ion inferior to other liquid chromatographic techniques with respect to precision and s sitivity (Fig. 3) [6]. [Pg.743]


See other pages where Precision chromatography is mentioned: [Pg.589]    [Pg.509]    [Pg.10]    [Pg.344]    [Pg.244]    [Pg.244]    [Pg.250]    [Pg.46]    [Pg.52]    [Pg.5]    [Pg.228]    [Pg.499]    [Pg.502]    [Pg.80]    [Pg.103]    [Pg.229]    [Pg.229]    [Pg.1026]    [Pg.90]    [Pg.279]    [Pg.16]    [Pg.66]    [Pg.108]    [Pg.292]    [Pg.3]    [Pg.141]    [Pg.244]    [Pg.169]    [Pg.15]    [Pg.138]   
See also in sourсe #XX -- [ Pg.190 ]




SEARCH



High performance liquid chromatography precision

High precision liquid chromatography

High precision liquid chromatography HPLC)

Precision column chromatography

Reverse-phase liquid chromatography precision