Pneumatics columns

Mechanical flotation machines are most commonly used in the mineral industiy, while pneumatic column-type units are gaining popularity in recent years. Surveys by Harris (1976), Young (1982), Bar-beiy (1982), and Mavros (1991) provide a detailed overview of the process-engineering aspec ts of mineral flotation devices in particular and systems in general. [Pg.1813]

Thermospray nebulizers are somewhat expensive but can be used on-line to a liquid chromatographic column. About 10% of sample solution is transferred to the plasma flame. The overall performance of the thermospray device compares well with pneumatic and ultrasonic sprays. When used with microbore liquid chromatographic columns, which produce only about 100 pl/min of eluant, the need for spray and desolvation chambers is reduced, and detection sensitivities similar to those of the ultrasonic devices can be attained both are some 20 times better than the sensitivities routinely found in pneumatic nebulizers. [Pg.150]

To escape aggregative fluidization and move to a circulating bed, the gas velocity is increased further. The fast-fluidization regime is reached where the soHds occupy only 5 to 20% of the bed volume. Gas velocities can easily be 100 times the terminal velocity of the bed particles. Increasing the gas velocity further results in a system so dilute that pneumatic conveying (qv), or dilute-phase transport, occurs. In this regime there is no actual bed in the column. [Pg.73]

Dry dense medium (pneumatic fluidized-bed) separation has been used, but has not received wide attention by the industry. An area of promise for future development is the use of magnetically stabilized dense medium beds by using ferro or magnetic fluids (2,10). Laboratory and pilot-scale units such as Magstream are available. In this unit, material is fed into a rotating column of water-based magnetic fluid. Particles experience centtifugal forces and... [Pg.407]

Pneumatic systems use the wave motion to pressurize air in an oscillating water column (OWC). The pressurized air is then passed through an air turbine to generate electricity. In hydrauhc systems, wave motion is used to pressurize water or other fluids, which are subsequendy passed through a turbine or motor that drives a generator. Hydropower systems concentrate wave peaks and store the water dehvered in the waves in an elevated basin. The potential energy suppHed mns a low head hydro plant with seawater. [Pg.111]

Distribution of the scoured wool to the cards then occurs. This is often done using a combination of pneumatic and mechanical transport systems, usually with the provision of accumulator bins that hold a few hour s production. Modem cards are usually fed with tower feeds, which automatically control the height of the wool column. [Pg.345]

Recently it has been shown that rotating coiled columns (RCC) can be successfully applied to the dynamic (flow-through) fractionation of HM in soils and sediments [1]. Since the flow rate of the extracting reagents in the RCC equipment is very similar to the sampling rate that is used in the pneumatic nebulization in inductively coupled plasma atomic emission spectrometer (ICP-AES), on-line coupling of these devices without any additional system seems to be possible. [Pg.459]

Figure 4.6 The LMCS system incorporates a moveable cryogenic ti ap T through which the capillary column is passed. The modulator (M) can be a pneumatic or motor driven device that moves T up and down as required, according to either preselected times (for a selective mode) or at a fast constant period for GC X GC. Figure 4.6 The LMCS system incorporates a moveable cryogenic ti ap T through which the capillary column is passed. The modulator (M) can be a pneumatic or motor driven device that moves T up and down as required, according to either preselected times (for a selective mode) or at a fast constant period for GC X GC.
The pneumatic pump has a relatively large flow capacity but, today, is largely used for column packing and not for LC analyses. It can provide extremely high pressures and is relatively inexpensive, but the high pressure models are a little bulky. A diagram of a pneumatic pump is shown in figure 4. [Pg.128]

The HPLC system used consisted of a 30 x 2 mm Luna CN column with linear gradient elution employing two mobile phases A and B (A, 90% H2O 10% acetonitrile B, 10% H2O 90% acetonittile) with both phases containing 5 mM ammonium acetate and 0.2% formic acid. The hnear gradient commenced with 50 50 A B increasing to 100% B after 1 min of the analysis this composition was maintained for 1 min before returning to 50 50 A B after 4 min. Positive-ion ionspray (pneumatically assisted electrospray) was used to obtain mass spectra, with the spectrometer operating at a resolution of 5000. [Pg.284]

In the pneumatic pumping system, the pressure (and not the flow rate) is maintained constant as variations in chromatographic conditions occur. Thus, a change in mobile phase viscosity (e.g. gradient elution) or column back pressure will result in a change in flow rate for these types of pumps. The gas displacement pump in which a solvent is delivered to the column by gas pressure is an example of such a pneumatic pump. The gas displacement system is among the least expensive pumps available and is found in several low cost instruments. While the pump is nonpulsating and hence, produces low noise levels with the detectors in current use, its flow stability and reproducibility are only adequate. In addition, its upper pressure limit is only 2000 psi which may be too low in certain applications. [Pg.232]

The reactors are cylindrical in shape and can carry up to 30 mg of resin. Polymer sieves at the top and bottom of the cylinders serve for liquid feed and withdrawal. The array of reactors is attached to a capillary system allowing feed to either columns or rows. This distribution system is said to provide uniform charges to the various reactors. A specific detail of the reaction system is that mixing is achieved by pneumatic actuation using a fluoropolymer membrane (Figure 4.36). [Pg.417]

In many cases it is possible to convert an older packed column gas chromatograph to accept open tubular capillary coluans [15-18]. Normally this will involve changes to the pneumatic... [Pg.123]

An option for upgrading blast resistance of an existing building may be to provide additional beams, columns, or walls strengthened with a mortar or concrete pneumatically projected at high velocity onto a surface. The concrete is placed on a cage of reinforcement, which is doweled into elements of the existing stmcture. [Pg.42]

LC-APCI-MS is a derivative of discharge-assisted thermospray, where the eluent is ionised at atmospheric pressure. In an atmospheric pressure chemical ionisation (APCI) interface, the column effluent is nebulised, e.g. by pneumatic or thermospray nebulisation, into a heated tube, which vaporises nearly all of the solvent. The solvent vapour acts as a reagent gas and enters the APCI source, where ions are generated with the help of electrons from a corona discharge source. The analytes are ionised by common gas-phase ion-molecule reactions, such as proton transfer. This is the second-most common LC-MS interface in use today (despite its recent introduction) and most manufacturers offer a combined ESI/APCI source. LC-APCI-MS interfaces are easy to operate, robust and do not require extensive optimisation of experimental parameters. They can be used with a wide variety of solvent compositions, including pure aqueous solvents, and with liquid flow-rates up to 2mLmin-1. [Pg.506]

Compared to syringe type or reciprocating pumps, pneumatic amplifier pumps are very cheap. They tend to be rather difficult to dismantle for repairs, and some types are very noisy in operation. Because they do not provide a constant flow of mobile phase, they are not used much in analytical hplc. They can, however, operate at high pressures and flow rates and so are used mainly for packing columns, where high pressures are needed and variations in the flow rate through the column do not matter. [Pg.261]

To enhance automation capacity, a direct transfer of the acceptor phase to a HPLC system can be arranged by setting up a pre-column that allows the injection of as much volume of analyte as possible (Figure 1.33). Pneumatically or electrically actuated valves controlled by a computer provide... [Pg.40]

The determination of the total concentrations of metal ions and arsenic in the water samples and in the eluates of solid materials were carried out using ICP-AES (Spectroflame, SPECTRO A.I.) with pneumatic nebulization (cross flow). Anion (S042, Cl ) determinations were done using an ion chromatographic device with IonPac AS12A/AG12A column and a conductivity detector. [Pg.67]


See other pages where Pneumatics columns is mentioned: [Pg.52]    [Pg.52]    [Pg.412]    [Pg.413]    [Pg.248]    [Pg.110]    [Pg.1223]    [Pg.1599]    [Pg.1814]    [Pg.1815]    [Pg.313]    [Pg.322]    [Pg.410]    [Pg.242]    [Pg.9]    [Pg.110]    [Pg.265]    [Pg.287]    [Pg.322]    [Pg.325]    [Pg.416]    [Pg.638]    [Pg.795]    [Pg.910]    [Pg.911]    [Pg.526]    [Pg.254]    [Pg.102]    [Pg.563]    [Pg.137]   
See also in sourсe #XX -- [ Pg.132 ]