Optical emission plasma

Optical emission (plasma) The emission of radiation from a plasma due to de-excitation of excited species. [Pg.665]

Analyses of alloys or ores for hafnium by plasma emission atomic absorption spectroscopy, optical emission spectroscopy (qv), mass spectrometry (qv), x-ray spectroscopy (see X-ray technology), and neutron activation are possible without prior separation of hafnium (19). Alternatively, the combined hafnium and zirconium content can be separated from the sample by fusing the sample with sodium hydroxide, separating silica if present, and precipitating with mandelic acid from a dilute hydrochloric acid solution (20). The precipitate is ignited to oxide which is analy2ed by x-ray or emission spectroscopy to determine the relative proportion of each oxide. [Pg.443]

Spectroscopic methods for the deterrnination of impurities in niobium include the older arc and spark emission procedures (53) along with newer inductively coupled plasma source optical emission methods (54). Some work has been done using inductively coupled mass spectroscopy to determine impurities in niobium (55,56). X-ray fluorescence analysis, a widely used method for niobium analysis, is used for routine work by niobium concentrates producers (57,58). Paying careful attention to matrix effects, precision and accuracy of x-ray fluorescence analyses are at least equal to those of the gravimetric and ion-exchange methods. [Pg.25]

Aluminum is best detected quaUtatively by optical emission spectroscopy. SoHds can be vaporized direcdy in a d-c arc and solutions can be dried on a carbon electrode. Alternatively, aluminum can be detected by plasma emission spectroscopy using an inductively coupled argon plasma or a d-c plasma. Atomic absorption using an aluminum hoUow cathode lamp is also an unambiguous and sensitive quaUtative method for determining alurninum. [Pg.105]

Highly sensitive iastmmental techniques, such as x-ray fluorescence, atomic absorption spectrometry, and iaductively coupled plasma optical emission spectrometry, have wide appHcation for the analysis of silver ia a multitude of materials. In order to minimize the effects of various matrices ia which silver may exist, samples are treated with perchloric or nitric acid. Direct-aspiration atomic absorption (25) and iaductively coupled plasma (26) have silver detection limits of 10 and 7 l-lg/L, respectively. The use of a graphic furnace ia an atomic absorption spectrograph lowers the silver detection limit to 0.2 l-ig/L. [Pg.91]

Numerous methods have been pubUshed for the determination of trace amounts of tellurium (33—42). Instmmental analytical methods (qv) used to determine trace amounts of tellurium include atomic absorption spectrometry, flame, graphite furnace, and hydride generation inductively coupled argon plasma optical emission spectrometry inductively coupled plasma mass spectrometry neutron activation analysis and spectrophotometry (see Mass spectrometry Spectroscopy, optical). Other instmmental methods include polarography, potentiometry, emission spectroscopy, x-ray diffraction, and x-ray fluorescence. [Pg.388]

Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES)... [Pg.48]

In Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES), a gaseous, solid (as fine particles), or liquid (as an aerosol) sample is directed into the center of a gaseous plasma. The sample is vaporized, atomized, and partially ionized in the plasma. Atoms and ions are excited and emit light at characteristic wavelengths in the ultraviolet or visible region of the spectrum. The emission line intensities are proportional to the concentration of each element in the sample. A grating spectrometer is used for either simultaneous or sequential multielement analysis. The concentration of each element is determined from measured intensities via calibration with standards. [Pg.48]

The Inductively Coupled Plasma (ICP) has become the most popular source for multielement analysis via optical spectroscopy since the introduction of the first commercial instruments in 1974. About 6000 ICP-Optical Emission Spectrometry (ICP-OES) instruments are in operation throughout the world. [Pg.633]

Instrumentation for inductively coupled plasma-optical emission spectrometry. [Pg.635]

For intermediate temperatures from 400-1000°C (Fig. 11), the volatilization of carbon atoms by energetic plasma ions becomes important. As seen in the upper curve of Fig. 11, helium does not have a chemical erosion component of its sputter yield. In currently operating machines the two major contributors to chemical erosion are the ions of hydrogen and oxygen. The typical chemical species which evolve from the surface, as measured by residual gas analysis [37] and optical emission [38], are hydrocarbons, carbon monoxide, and carbon dioxide. [Pg.414]

Lomer, M.C.E. et ah. Determination of titanium dioxide in foods using inductively coupled plasma optical emission spectrometry. Analyst, 125, 2339, 2002. [Pg.124]

Plasma analysis is essential in order to compare plasma parameters with simulated or calculated parameters. From the optical emission of the plasma one may infer pathways of chemical reactions in the plasma. Electrical measurements with electrostatic probes are able to verify the electrical properties of the plasma. Further, mass spectrometry on neutrals, radicals, and ions, either present in or coming out of the plasma, will elucidate even more of the chemistry involved, and will shed at least some light on the relation between plasma and material properties. Together with ellipsometry experiments, all these plasma analysis techniques provide a basis for the model of deposition. [Pg.28]

In order to relate material properties with plasma properties, several plasma diagnostic techniques are used. The main techniques for the characterization of silane-hydrogen deposition plasmas are optical spectroscopy, electrostatic probes, mass spectrometry, and ellipsometry [117, 286]. Optical emission spectroscopy (OES) is a noninvasive technique and has been developed for identification of Si, SiH, Si+, and species in the plasma. Active spectroscopy, such as laser induced fluorescence (LIF), also allows for the detection of radicals in the plasma. Mass spectrometry enables the study of ion and radical chemistry in the discharge, either ex situ or in situ. The Langmuir probe technique is simple and very suitable for measuring plasma characteristics in nonreactive plasmas. In case of silane plasma it can be used, but it is difficult. Ellipsometry is used to follow the deposition process in situ. [Pg.79]

As can most clearly be seen in Figure 46d, the a-y transition occurs at a pressure of about 0.3 mbar for these experimental conditions. The impedance of the plasma, as well as the optical emission from the plasma, changes on going through the transition. The depletion of SiHq during deposition was already shown and... [Pg.123]

At the start of each modulation pulse, a sharp peak in optical emission is seen. Similar SiH emission peaks in pulsed plasmas have been found by Scarsbrook et al. [516] and Howling et al. [321]. The sharp peak was claimed to be caused by a pulse of high-energy electrons. Overzet and Verdeyen [517] measured electron densities at a 2.9-MHz excitation frequency and modulation frequencies up to 20 kHz. The optical emission of a SQWM argon plasma was measured by Booth et al. [518], who also performed particle-in-cell modeling. [Pg.152]

Knowledge on the plasma species can be obtained by the use of plasma diagnostics techniques, such as optical emission spectroscopy (OES) and mass spectroscopy (MS). Both techniques are able to probe atomic and molecular, neutral or ionized species present in plasmas. OES is based on measuring the light emission spectrum that arises from the relaxation of plasma species in excited energy states. MS, on the other hand, is generally based on the measurement of mass spectra of ground state species. [Pg.236]

Inductively Coupled Plasma Mass Spectrometry Inductively Coupled Plasma Optical Emission Spectrometry Ion Cyclotron Resonance Ion Diffraction... [Pg.25]

Thiel G, Danzer K (1997) Direct analysis of mineral components in wine by inductively coupled plasma optical emission spectrometry (ICP-OES). Fresenius J Anal Chem 357 553... [Pg.241]

Berndt et al. [740] have shown that traces of bismuth, cadmium, copper, cobalt, indium, nickel, lead, thallium, and zinc could be separated from samples of seawater, mineral water, and drinking water by complexation with the ammonium salt of pyrrolidine- 1-dithiocarboxylic acid, followed by filtration through a filter covered with a layer of active carbon. Sample volumes could range from 100 ml to 10 litres. The elements were dissolved in nitric acid and then determined by atomic absorption or inductively coupled plasma optical emission spectrometry. [Pg.261]


See other pages where Optical emission plasma is mentioned: [Pg.335]    [Pg.625]    [Pg.221]    [Pg.309]    [Pg.118]    [Pg.407]    [Pg.71]    [Pg.112]    [Pg.119]    [Pg.237]    [Pg.148]    [Pg.665]    [Pg.615]    [Pg.616]    [Pg.26]    [Pg.1013]    [Pg.162]    [Pg.125]    [Pg.596]    [Pg.629]    [Pg.197]    [Pg.314]   