Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Multi detection

Dendrimer chemistry has taught us that these molecules create a nano-sized closed space that, presumably, is the origin of the specific physical properties of this class of materials. As the next stage of dendrimer chemistry, a macromolecule capable of creating such a space inside its molecule is proposed. To create the nano-sized space, porphyrin is considered to be the best candidate for the component molecules, because it has versatile properties associated with its expanded 7i-electron system and the incorporated metal. The resultant multi-detectable properties of porphyrin, that is, a number of its properties are detectable by many physical methods, may reveal the function of the nanometer-sized space. [Pg.65]

Keywords. Nano-sized space. Porphyrin, Cyclic oligomer. Multi-detectable molecule. Inverse-template effect... [Pg.65]

Porphyrin is a multi-detectable molecule, that is, a number of its properties are detectable by many physical methods. Not only the most popular nuclear magnetic resonance and light absorption and emission spectroscopic methods, but also the electron spin resonance method for paramagnetic metallopor-phyrins and Mossbauer spectroscopy for iron and tin porphyrins are frequently used to estimate the electronic structure of porphyrins. By using these multi-detectable properties of the porphyrins of CPOs, a novel physical phenomenon is expected to be found. In particular, the topology of the cyclic shape is an ideal one-dimensional state of the materials used in quantum physics [ 16]. The concept of aromaticity found in fuUerenes, spherical aromaticity, will be revised using TT-conjugated CPOs [17]. [Pg.70]

Cell inhibition rate analysis Cells were seeded in 96-well plates at a density of 1.5/ 104 cells/well in quadruplicate and incubated at 37°C in a 5% C02 atmosphere. After 24 hr, cells were treated with 0.1% DMSO (control) or, compound at various concentrations (0.01 - 0.33 mM) for 48 hr. Cell inhibition rate was analyzed after 48 hr using the Cell Counting Kit CCK-8 (Dojindo Laboratories, Japan), according to the manufacturer s instructions. OD values were measured at a wavelength of 450 nm using a Multi-Detection Microplate-Reader (Bio-TEK, Winooski, VT). [Pg.102]

In flow analysis, multi-detection is generally accomplished by resorting to multichannel flow analysers, and each channel incorporates a different dedicated detector. Another possibility is to take advantage of multi-parametric techniques such as ICP-OES, anodic stripping voltammetry and UV—visible spectrophotometry with diode array detection. A deeper presentation of this aspect is outside of the scope of this monograph. [Pg.273]

The detection technique most commonly used with methods based on fast kinetics is photometry (either in its conventional form or with multi-detection systems such as image detectors) and, to a much lesser extent, fluorimetric and electroanalytical methods. [Pg.217]

These systems have two major limitations on the one hand, the number of channels must be small as each sensing element, however miniaturized, occupies considerable space with Its independent associated electronics on the other hand, and as a result of the first limitation, the spectral Information obtained is necessarily partial, although in some cases (e.g. in atomic spectroscopy and routine UV-vIsible determinations) It Is more than sufficient. Nevertheless, the development and consolidation of electronic image sensors have displaced them to a less prominent place in the context of simultaneous multi-detection. [Pg.299]

The rapid growth of instruments with built-in microprocessors or computers has been the result of a number of reasons. First, the enormous growth of the number of clinical analyses required, which increased by 10-20% yearly between 1970 and 1980. Second, the need for better performance from analysers whose precision could not be improved or even preserved without computerization. Even the basic concept behind some analysers (e.g. centrifugal analysers) or enzymatic rate measurements with multi-detection are not feasible without recourse to computerization. [Pg.429]

Non-destructive detectors usually measure a physical property of the eluent. The detected compounds are neither decomposed nor is the structure changed. Ionization processes are non-destructive as long as no dissociative reaction takes place, such as cleave-off of functional groups. Non-destructive detectors can be combined with other detectors in multi-detection systems. [Pg.133]

An example of a Magnetic Sector-based SIMS instrument that has proved effective in this area is the Cameca nanoSIMS-50. Indeed, this instrument is capable of full transmission at a mass resolution up to m/A m of 2000 (higher mass resolution obtained at the expense of transmission). This instrument also incorporates a multi-detection system and normal incidence primary ion beams that can be focused to below 50 nm. Mass resolution, along with definitions, is covered in Section 5.2.2.2. [Pg.16]

Brod, F. C. A., J. P. van Dijk, M. M. Voorhuijzen et al. 2014. A high-throughput method for GMO multi-detection using a microfluidic dynamic array. Anal. Bioanal. Chem. 406 1397-1410. [Pg.75]

Domino dendrimers may also be applied as a general platform for sensor molecules used to detect enzymatic activity. The reporter units could be any molecule with a hidden signal, which is revealed upon the unit release. The dendritic platform will act as a molecular enhancer, which amphfies a single enzymatic activation into multi-detectable signals. [Pg.91]

Further applications of M IPs for speciation include the use of supercritical-fluid chromatography for the determination of P, Cl, N, Si, Fe, and Zn species as car lubricant additives [531]. Hyphenation of packed-column supercritical fluid chromatography (SFC) to microwave-induced plasma optical emission spectrometry (MIP-OES) by flow-splitting via a restrictor to enable multi-detection, including UV or flame-ionization detection, has also been described. [Pg.260]


See other pages where Multi detection is mentioned: [Pg.471]    [Pg.3]    [Pg.369]    [Pg.244]    [Pg.244]    [Pg.273]    [Pg.273]    [Pg.273]    [Pg.275]    [Pg.277]    [Pg.279]    [Pg.281]    [Pg.283]    [Pg.71]    [Pg.142]    [Pg.174]    [Pg.188]    [Pg.296]    [Pg.301]    [Pg.304]    [Pg.1172]    [Pg.2964]    [Pg.199]   
See also in sourсe #XX -- [ Pg.186 ]




SEARCH



© 2024 chempedia.info