Flow Analyses

In automated flow analysis, samples are analysed as they are pumped in sequence through a series of tubing containing a continuously flowing reagent stream. [Pg.217]

The sequential multiple analysers (SMAs) were later developments and they were much more complex in design and included a computer. They could analyse each sample for several constituents simultaneously, the number of channels determining this capacity, i.e. 6, 12 or 20. These instruments were developed primarily for hospital clinical chemistry laboratories to allow an overall assessment of the chemical composition of blood samples. They have now been superseded by other types of analysers. [Pg.217]

The samples are aspirated in sequence into the reagent stream with a small volume of water separating each one. Air bubbles are introduced into the flowing stream and in order to maintain a regular liquid-air pattern in the stream, a wetting agent, e.g. Brij 35, is usually added to the liquids. [Pg.217]

The air bubbles have several important functions and are fundamental to [Pg.217]

Quantitation in continuous flow analysis is based on the direct comparison of the peak heights on a recorder trace of the samples and standards. It is not necessary for the reactions to go to completion, because all the measurements in a particular method are made after the same fixed reaction time, which is determined by the length of analyser tubing and relies on a constant pump speed. [Pg.218]

An electrochemical detector uses the electrochemical properties of target analytes for their determination in a flowing stream. While parameters such as current, potential, [Pg.84]

FIGURE 3-19 Elements measured by conventional ASV , and adsorptive stripping schemes with reduction of the element in the complex M, reduction of the ligand or catalytic process B. (Reproduced with permission from reference 40.) [Pg.85]

Metal Sample Matrix Stripping Mode Working Electrode Reference [Pg.85]

In practice, even though with the developments that has occurred in the past and continues this perfect homogeneous stable situation is never achieved and there are variables that continually affect the output. If the process is analyzed one can decide that two types of variables affect the quality and output rate. They can be identified as  [Pg.398]

2 the operating or dynamic variables, which control how the machine is run. [Pg.398]

Software provides simulation of the desired process and comparison with reality. The purpose of flow analysis is to gain a comprehensive imderstanding of the melt flow filling process based on process controls. The most sophisticated computer models provide detailed information concerning the influence of filling conditions on the [Pg.398]


Life cycle cost analysis is the proper tool for evaluation of alternative systems (11,12). The total cost of a system, including energy cost, maintenance cost, interest, cash flow, equipment replacement and/or salvage value, taxes, inflation, and energy cost escalation, can be estimated over the useflE life of each alternative system. A Hst of life cycle cost items which may be considered for each system is presented in Tables 3 and 4. Reference 14 presents a cash flow analysis which also includes factors such as energy cost escalation. [Pg.363]

Electrical engineering Equipment design Expert systems Extraction Failure analysis Flow analysis Safety... [Pg.61]

Many developers of software for finite-element analysis (18) provide drafting of pipelines and associated flow analysis. These companies include Algor, McAuto, MacNeal-Schwindler, and ElowDesign. In software, in-house developed pipe fittings are modularized and isometric views of the piping systems with three-dimensional detailing are now commonplace. [Pg.62]

Gash Flow Examples. Several hypothetical ventures are presented to illustrate cash flow analysis. Venture A exhibits a cash flow analysis. Venture A exhibits a cash flow pattern typical of process ventures. Other ventures are introduced for comparison and to provide additional insight into cash flow analysis. [Pg.448]

FIG. 21-21 Flow analysis is made by observing an element of material as it moves tbroiigb tbe bin. (Coutiesy of Cbemical Engineering.)... [Pg.1938]

Dawes, W., 1995, A Simulation of the Unsteady Interaction of a Centrifugal Impeller with its Vaned Diffuser Flows Analysis, ASME Journal of Turbomachinery, Vol. 117, pp. 213-222. [Pg.273]

Gehring, S., and Riess, W., Through-Flow Analysis for Cooled Turbines. 3rd Conference on Turbomachinery-Fluid Dynamics and Thermodynamics, London March, 1999. [Pg.368]

The Lapple charts for compressible fluid flow are a good example for this operation. Assumptions of the gas obeying the ideal gas law, a horizontal pipe, and constant friction factor over the pipe length were used. Compressible flow analysis is normally used where pressure drop produces a change in density of more than 10%. [Pg.401]

BS EN 13395 nitrate and nitrite nitrogen flow analysis and spectrometry... [Pg.318]

If tv o-phase flow situations are not recognized, pressure drop problems may develop which can prevent systems from operating. It requires very little percentage of vapor, generally above 7% to 8%, to establish volumes and flow velocities that must be solved by two-phase flow analysis. The discharge flow through a pressure relief valve on a process reactor is often an important example where two-phase flow exists, and must be recognized for its back pressure impact. [Pg.124]

Figure 61.7 Cumulative cash flow Analysis of variances ... Figure 61.7 Cumulative cash flow Analysis of variances ...
The Maxwell model is also called Maxwell fluid model. Briefly it is a mechanical model for simple linear viscoelastic behavior that consists of a spring of Young s modulus (E) in series with a dashpot of coefficient of viscosity (ji). It is an isostress model (with stress 5), the strain (f) being the sum of the individual strains in the spring and dashpot. This leads to a differential representation of linear viscoelasticity as d /dt = (l/E)d5/dt + (5/Jl)-This model is useful for the representation of stress relaxation and creep with Newtonian flow analysis. [Pg.66]

PCs all have one thing in common. They monitor the process variables, compare them to values known to be acceptable, and make appropriate corrections without operator intervention. The acceptable range of values can be determined by using melt flow analysis software and/or trial and error when the machine is first starting its production. Using the software approach, the acceptable process values are known before the mold or die is ever built. It should be noted that none of the PC solutions address the problem of the lack of skilled setup people. Most of the PC systems available today are rather complex and require skilled people to use them efficiently or at least start up the line. [Pg.531]

Example 3-6 Flow analysis of a urine sample at a thin-layer amperometric detector, with a flow rate of 1.25mLmin yielded a limiting current value of 1.6 pA for its unknown uric acid content. A larger current of 2.4 pA was observed for a sample containing 1 x 10 4 M uric acid and flowing at a rate of 0.9 mL min. Calculate the original concentration of uric acid in the sample. [Pg.98]

A similar, but highly porous, vitreous carbon material—reticulated vitreous carbon (RVC)—has found widespread application for flow analysis and spectro-electrochemistry (25). As shown in Figure 4-10, RVC is an open-pore ( spongelike ) material such a network combines the electrochemical properties of glassy carbon with many structural and hydrodynamic advantages. These include a very high surface area ( 66 cm2 cm-3 for the 100-ppi grade), 90-97% void volume, and a low resistance to fluid flow. [Pg.114]

Hagsater, S.M. et al. (2008) A compact viewing configuration for stereoscopic micro-PIV utilizing mm-sized mirrors. Exp. Fluids, 45 (6), 1015-1021. Bernard, P.S. and Wallace, J.M. (2002) Turbulent Flow Analysis, Measurement... [Pg.354]

Hammoudi, M. et al. (2008) Flow analysis by pulsed ultrasonic velocimetry technique in SulzerSMX static mixer. Chem. Eng.]., 139 (3), 562-574. [Pg.354]

Micro reactors show, under certain conditions, low axial flow dispersion reactions with unstable intermediates can be carried out in a fast, stepwise manner on millisecond time-scales. Today s micro mixers mix on a millisecond scale and below [40]. Hence in micro reactors reactions can be carried out in the manner of a quench-flow analysis, used for determination of fast kinetics [93]. [Pg.444]

Microfabricated silicon mixers for submillisecond quench flow analysis. Anal. [Pg.573]

Gunasingham, H. and Fleet, B., Hydrodynamic voltammetry in continuous-flow analysis, in Electroanalytical Chemistry A Series of Advances, Vol. 16, Bard, A. J., Ed., Marcel Dekker, New York, 1989, 89. [Pg.271]

Brunt, K., Electrochemical detectors for high-performance liquid chromatography and flow analysis systems, Trace Analysis, Vol. 1, Lawrence, J. F., Ed., Academic Press, New York, 1981, 47-120. [Pg.271]


See other pages where Flow Analyses is mentioned: [Pg.291]    [Pg.181]    [Pg.85]    [Pg.1937]    [Pg.798]    [Pg.216]    [Pg.233]    [Pg.318]    [Pg.745]    [Pg.786]    [Pg.811]    [Pg.240]    [Pg.2]    [Pg.443]    [Pg.461]    [Pg.612]    [Pg.84]    [Pg.85]    [Pg.87]    [Pg.89]    [Pg.91]    [Pg.93]    [Pg.111]    [Pg.207]    [Pg.3]    [Pg.318]    [Pg.427]   
See also in sourсe #XX -- [ Pg.217 ]

See also in sourсe #XX -- [ Pg.98 , Pg.190 ]

See also in sourсe #XX -- [ Pg.84 , Pg.161 ]

See also in sourсe #XX -- [ Pg.22 , Pg.86 , Pg.96 ]

See also in sourсe #XX -- [ Pg.242 ]