Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Multi-analyzer

A bioprocess system has been monitored using a multi-analyzer system with the multivariate data used to model the process.27 The fed-batch E. coli bioprocess was monitored using an electronic nose, NIR, HPLC and quadrupole mass spectrometer in addition to the standard univariate probes such as a pH, temperature and dissolved oxygen electrode. The output of the various analyzers was used to develop a multivariate statistical process control (SPC) model for use on-line. The robustness and suitability of multivariate SPC were demonstrated with a tryptophan fermentation. [Pg.432]

Stinton TJ, Crowley D, Bryant SJ. Reference values of calcium, phosphate, and alkaline phosphatase as derived on the basis of multi-analyzer profiles. Clin Chem 1986 32 76-9. [Pg.472]

Cimander C, Bachinger T, Mandenius CP. Integration of distributed multi-analyzer monitoring and control in bioprocessing based on a real-time expert system. J Biotechnol 2003, 15 Aug 103(3) 237-248. [Pg.326]

Analyzers can be used in single, e.g., Q or TOE, or in multi-analyzer formats, e.g., QTOE and TOE/TOE, with a collision cell incorporated between the two analyzers. [Pg.35]

A further advancement in organic synthesis was the accomplishment of multi-step syntheses comprising 20 and more steps and the synthesis of rather unstable organic compounds. It was now feasible to do an experiment on a milligram scale and to separate and identify products from by-products in order to analyze them separately. The application of selective reagents or reaction conditions allowed the synthesis of enantiomerically or diastereomerically pure compounds. [Pg.569]

Multielemental Analysis Atomic emission spectroscopy is ideally suited for multi-elemental analysis because all analytes in a sample are excited simultaneously. A scanning monochromator can be programmed to move rapidly to an analyte s desired wavelength, pausing to record its emission intensity before moving to the next analyte s wavelength. Proceeding in this fashion, it is possible to analyze three or four analytes per minute. [Pg.436]

The advantages of LA are now well-known - no sample preparation is needed, conducting and non-conducting samples of arbitrary structure can be analyzed directly, spatial resolution up to a few microns can be obtained, high vacuum conditions are not required, rapid simultaneous multi-element analysis is possible, and it is possible to obtain complete analytical information with a single laser pulse. A brief overview of the potential and limitations of LA will be given in this chapter. [Pg.231]

In this paper, we analyze the methods of synthesizing multi-shell fullerene structures and try to gather some information about their formation mechanism. We also discuss some particularities of the energetics of onion-like graphitic particles. The understanding of the parameters involved would allow the development of efficient production procedures. [Pg.163]

The most common predictive technique which is used to analyze facilities which contain new equipment or processes, or where there is an unusually high risk to personnel or the environment is the Hazard and Operability technique or HAZOP. A HAZOP study requires a team of five to ten multi-discipline personnel consisting of representatives from engineering, operations, and health, safety, and environmental staff. The... [Pg.418]

An on-line supercritical fluid chromatography-capillary gas chromatography (SFC-GC) technique has been demonstrated for the direct transfer of SFC fractions from a packed column SFC system to a GC system. This technique has been applied in the analysis of industrial samples such as aviation fuel (24). This type of coupled technique is sometimes more advantageous than the traditional LC-GC coupled technique since SFC is compatible with GC, because most supercritical fluids decompress into gases at GC conditions and are not detected by flame-ionization detection. The use of solvent evaporation techniques are not necessary. SFC, in the same way as LC, can be used to preseparate a sample into classes of compounds where the individual components can then be analyzed and quantified by GC. The supercritical fluid sample effluent is decompressed through a restrictor directly into a capillary GC injection port. In addition, this technique allows selective or multi-step heart-cutting of various sample peaks as they elute from the supercritical fluid... [Pg.325]

Both time-domain and frequency-domain vibration data can be acquired and analyzed in two primary formats (1) steady-state or (2) dynamic. Each of these formats has strengths and weaknesses that must be clearly understood for proper use. Each of these formats can be obtained as single- or multi-channel data. [Pg.686]

Two-phase flows in micro-channels with an evaporating meniscus, which separates the liquid and vapor regions, have been considered by Khrustalev and Faghri (1996) and Peles et al. (1998, 2000). In the latter a quasi-one-dimensional model was used to analyze the thermohydrodynamic characteristics of the flow in a heated capillary, with a distinct interface. This model takes into account the multi-stage character of the process, as well as the effect of capillary, friction and gravity forces on the flow development. The theoretical and experimental studies of the steady forced flow in a micro-channel with evaporating meniscus were carried out by Peles et al. (2001). These studies revealed the effect of a number of dimensionless parameters such as the Peclet and Jacob numbers, dimensionless heat transfer flux, etc., on the velocity, temperature and pressure distributions in the liquid and vapor regions. The structure of flow in heated micro-channels is determined by a number of factors the physical properties of fluid, its velocity, heat flux on... [Pg.401]

After the chosen data file is read into MULTI, sequential columns K through L are selected for analysis K and L must be within the bounds 1. .. M, and L must be larger than K. If the columns one wants to analyze are separated by other data, use program DATA to first copy the unwanted column to column M + 1 by invoking the option (Add) and selecting the constant to be zero and then deleting the unwanted column. [Pg.377]

The above-mentioned targets refer to general advantages of micro reactors [42, 80, 100, 114, 119]. Enhanced transfer and better controlled residence time improve conversion and selectivity. The tools have small internal volumes, allowing one to generate flexibly a multitude of samples in serial or parallel fashion. Synthesis can be combined with a multi-step procedure. The economy of micro-reactor processes has not really been analyzed so far however, it is clear that as laboratory tools they allow in a number of cases technical expenditure, personnel and costs to be reduced. [Pg.475]

In the analysis of complex PAH mixtures obtained from environmental samples, reversed-phase LC-FL typically provides reliable results for only 8-12 major PAHs (Wise et al. 1993a). To increase the number of PAHs determined by LC-FL, a multidimensional LC procedure is used to isolate and enrich specific isomeric PAHs that could not be measured easily in the total PAH fraction because of interferences, low concentrations, and/or low fluorescence sensitivity or selectivity. This multi-dimensional procedure, which has been described previously (Wise et al. 1977 May and Wise 1984 Wise et al. 1993a, 1993b), consists of a normal-phase LC separation of the PAHs based on the number of aromatic carbon atoms in the PAH, thereby providing fractions containing only isomeric PAHs and their alkyl-substituted isomers. These isomeric fractions are then analyzed by reversed-phase LC-FL to separate and quantify the various isomers. [Pg.94]

Error 1 CRMs completely or partly not identical with the matrix to be analyzed Ber-mejo-Barrera et al. (1999) studied enzymatic hydrolysis procedures using pronase E as sample pretreatment for multi-element - Cu, Fe, Mg, Zn, Ag, As, Cd, and Pb -determination in biological materials, mussel samples and human hair. [Pg.261]

Fig. 3.3 Velocity control and synchronization of data recording by the multi-channel analyzer (MCA) operated in MCS mode with 512 channels. For the common triangular velocity profile shown here the spectrum is recorded twice, because each velocity increment is reached upon sweeping up and down. The sense of the velocity scales may also be opposite to that shown here, which means the MCA sweep may also start at... Fig. 3.3 Velocity control and synchronization of data recording by the multi-channel analyzer (MCA) operated in MCS mode with 512 channels. For the common triangular velocity profile shown here the spectrum is recorded twice, because each velocity increment is reached upon sweeping up and down. The sense of the velocity scales may also be opposite to that shown here, which means the MCA sweep may also start at...
Fig. 3.7 Pulse-height analysis (PHA) Function of the single-channel analyzer (SCA) and data recording by the multi-channel analyzer (MCA). The output (L) of the SCA yields a 5 V squareshaped pulse, a so-called TTL pulse for each y-pulse matching the voltage selection window. The SCA is set to select the Mossbauer pulses for the subsequent measurement... Fig. 3.7 Pulse-height analysis (PHA) Function of the single-channel analyzer (SCA) and data recording by the multi-channel analyzer (MCA). The output (L) of the SCA yields a 5 V squareshaped pulse, a so-called TTL pulse for each y-pulse matching the voltage selection window. The SCA is set to select the Mossbauer pulses for the subsequent measurement...
Moreover, new technologies such as LC/MS/MS should be considered and their potential should be recognized in the future. Currently food control laboratories monitor only a part of the pesticides used in their routine work. They prefer active ingredients that can be analyzed by multi-methods or some group-specific methods, because resources to check all relevant pesticides are normally not available. Therefore, many a.i. are monitored only on a case-by-case basis or not at all. An LC/MS multi-residue method, which may be developed in the future, could cover this gap to a large extent. [Pg.36]

The enforcement methods provided by the applicants give basic information about appropriate cleanup steps and specific determination procedures. Typically, direct use of this developmental work occurred when a GC multi-residue method was found appropriate. Owing to the recent developments in the field of MS/MS with atmospheric pressure ionization, an alternative approach for those compounds that can be analyzed by liquid chromatography (LC) will soon be possible. It is important that some fundamental considerations for such method(s) should be agreed at the outset. Considerations include the most suitable extraction solvents and cleanup steps and some standard HPLC conditions. [Pg.111]

The sensitivity achieved (LOD) is not normally presented. It is recognized that different laboratories determine dissimilar values for this parameter and even within a laboratory the repeatability of the LOD is low. Most often, the lowest validated concentration gives an impression about the lowest levels that can be analyzed generally with acceptable results. A measure of selectivity is the intensity of blank results. This intensity is discussed by the participants of inter-laboratory validation studies. However, results are not reported and limits are not defined by CEN TC 275. The results of method validations of the several multi-residue/multi-matrix methods are not reported in the same way, but newer methods with limited scope generate analogous tables with validation results (as an example, see Table 7). [Pg.115]

To reduce the effort, another validation procedure is used for extension of the German multi-residue method to a new analyte. Actually, more than 200 pesticides can be analyzed officially with this method, which is the up-to-date version of the better known method DFG SI9. A typical validation is performed by at least three laboratories, which conduct fortification experiments at the same three levels with at least four representative matrices. These representative matrices are commodities with high water content (e.g., tomato), fruits with high acid content (e.g., lemon), dry crops (e.g., cereals) and commodities with high fat content (e.g., avocado). [Pg.125]


See other pages where Multi-analyzer is mentioned: [Pg.251]    [Pg.261]    [Pg.251]    [Pg.261]    [Pg.2]    [Pg.37]    [Pg.290]    [Pg.151]    [Pg.241]    [Pg.358]    [Pg.303]    [Pg.282]    [Pg.720]    [Pg.46]    [Pg.362]    [Pg.24]    [Pg.81]    [Pg.103]    [Pg.42]    [Pg.552]    [Pg.10]    [Pg.307]    [Pg.212]    [Pg.26]    [Pg.26]    [Pg.93]    [Pg.97]   
See also in sourсe #XX -- [ Pg.12 , Pg.17 , Pg.74 , Pg.91 , Pg.246 ]




SEARCH



Multi-channel analyzer

© 2024 chempedia.info