Dissolved oxygen electrodes

The dissolved oxygen concentrations are determined immediately and after five days. The method for dissolved measurement involves either a modified Winkler titration or a membrane-covered oxygen electrode. The difference between initial and final dissolved oxygen multiphed by the dilution factor is the BOD value. [Pg.232]

FIG. 24-14 Dissolved-oxygen electrodes a) polarographic (impress breakdown voltage for oxygen measure current) (h) voltametric (measure electromotive force). [Pg.2139]

Bioprocess Control An industrial fermenter is a fairly sophisticated device with control of temperature, aeration rate, and perhaps pH, concentration of dissolved oxygen, or some nutrient concentration. There has been a strong trend to automated data collection and analysis. Analog control is stiU very common, but when a computer is available for on-line data collec tion, it makes sense to use it for control as well. More elaborate measurements are performed with research bioreactors, but each new electrode or assay adds more work, additional costs, and potential headaches. Most of the functional relationships in biotechnology are nonlinear, but this may not hinder control when bioprocess operate over a narrow range of conditions. Furthermore, process control is far advanced beyond the days when the main tools for designing control systems were intended for linear systems. [Pg.2148]

Mounting electrodes in a bioreactor is costly, and there is an additional contamination risk for sensitive cell cultures. Some other sensors of prac ticai importance are those for dissolved oxygen and for dissolved carbon dioxide. The analysis of gas exiting from a bioreactor with an infrared unit that detects carbon dioxide or a paramagnetic unit that detects oxygen (after carbon dioxide removal) has been replaced by mass spec trophotometry. Gas chromatographic procedures coupled with a mass spectrophotometer will detect 1 the volatile components. [Pg.2148]

PSS-SG composite film was tested for sorption of heme proteins hemoglobin (Hb) and myoglobin (Mb). The peroxidaze activity of adsorbed proteins were studied and evaluated by optical and voltammetric methods. Mb-PSS-SG film on PG electrode was shown to be perspective for detection of dissolved oxygen and hydrogen peroxide by voltammetry with linear calibration in the range 2-30 p.M, and detection limit -1.5 p.M. Obtained composite films can be modified by different types of biological active compounds which is important for the development of sensitive elements of biosensors. [Pg.306]

During the operation of the cell (or during the direct interaction of zinc metal and cupric ions in a beaker) the zinc is oxidised to Zn and corrodes, and the Daniell cell has been widely used to illustrate the electrochemical mechanism of corrosion. This analogy between the Daniell cell and a corrosion cell is perhaps unfortunate, since it tends to create the impression that corrosion occurs only when two dissimilar metals are placed in contact and that the electrodes are always physically separable. Furthermore, although reduction of Cu (aq.) does occur in certain corrosion reactions it is of less importance than reduction of HjO ions or dissolved oxygen. [Pg.84]

Although Table 2.16 shows which metal of a couple will be the anode and will thus corrode more rapidly, little information regarding the corrosion current, and hence the corrosion rate, can be obtained from the e.m.f. of the cell. The kinetics of the corrosion reaction will be determined by the rates of the electrode processes and the corrosion rates of the anode of the couple will depend on the rate of reduction of hydrogen ions or dissolved oxygen at the cathode metal (Section 1.4). [Pg.368]

Discussion. One of the most useful titrations involving iodine is that originally developed by Winkler18 to determine the amount of oxygen in samples of water. The dissolved oxygen content is not only important with respect to the species of aquatic life which can survive in the water, but is also a measure of its ability to oxidise organic impurities in the water (see also Section 10.103). Despite the advent of the oxygen-selective electrode (Section 16.36) direct titrations on water samples are still used extensively.19... [Pg.395]

The concentration of dissolved oxygen in a fermenter is normally measured with a dissolved oxygen electrode, known as a DO probe. There are two types in common use galvanic... [Pg.14]

In general, corrosion of metal is always accompanied by dissolution of a metal and reduction of an oxidant such as a proton in acidic solution and dissolved oxygen in a neutral solution. That is, metal corrosion is not a single electrode reaction, but a complex reaction composed of the oxidation of metal atoms and the reduction of oxidants. [Pg.217]

If components of the solution phase are prone to electrochemical reactions (e.g. reduction of dissolved oxygen, reduction of oxidising anions) their presence may also cause Faradaic reactions and the subsequent establishment of an electrode potential different from iipzc. [Pg.184]

The DAC system consisted of computer, interface cards, meters, transmitters, and solid state relays (SSR). Electrodes of pH (Ingold), Oxidation-Reduction Potential (Cole-Parmer), and Dissolved Oxygen (Ingold) were installed and connected to individual meter. The status of reactor and the value of electrode signal were displayed in a computer monitor, and stored in data file. [Pg.167]


See other pages where Dissolved oxygen electrodes is mentioned: [Pg.232]    [Pg.233]    [Pg.155]    [Pg.995]    [Pg.238]    [Pg.5145]    [Pg.473]    [Pg.232]    [Pg.233]    [Pg.155]    [Pg.995]    [Pg.238]    [Pg.5145]    [Pg.473]    [Pg.333]    [Pg.232]    [Pg.281]    [Pg.2139]    [Pg.2148]    [Pg.373]    [Pg.1317]    [Pg.69]    [Pg.90]    [Pg.94]    [Pg.187]    [Pg.217]    [Pg.312]    [Pg.1220]    [Pg.1008]    [Pg.1200]    [Pg.1250]    [Pg.228]    [Pg.593]    [Pg.603]    [Pg.617]    [Pg.621]    [Pg.629]    [Pg.254]    [Pg.72]    [Pg.79]    [Pg.333]    [Pg.201]    [Pg.158]    [Pg.271]    [Pg.390]    [Pg.407]   