Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Module declaration

A module instantiation statement can be written within a module declaration. A synthesis system treats such a module instance as a black box and does not take further action, that is, the module instance appears in the synthesized netlist as if it were a primitive component. Here is an example of a full-adder module that contains one module instantiation statement. Notice that in the synthesized netlist, shown in Figure 2-67, the module MyXor appears just as it is described in the top level module FullAdderMix. [Pg.98]

In fact this is an interpreter for the language Gofer[9], a close dialect of Haskell. As far as the facilities used in this document are concerned it is identical to Haskell, except that Haskell requires a module declaration which Gofer does not support. We use the Gofer interpreter because it is friendlier and faster to use than any we have (yet) found for Haskell. [Pg.138]

The modules are attributed in function of the different levels of risk inherent to the products. After having applied the modules applicable to a given product, the manufacturer issues a declaration of conformity and affixes the CE-marking. [Pg.939]

The sponsor must provide a declaration on these matters in Module 1 of the application for registration. [Pg.668]

Fig. 10.19a) and the appearance of breaks shown in Fig. 10.19b. This is an important result because in systems, living or engineered, it may be the only means of the declaration of success, that is, the actual location of the target (modulation source). It also shows that the range is longer for low frequencies (Fig. 10.19b, lines a and c). [Pg.336]

Module is used as a repository of declarations and procedures to design advanced Access applications. [Pg.29]

A module is organised into a number of procedures, either subroutines of functions. A subroutine without arguments is declared as Sub new () and is recognised as a macro that can be called directly from Excel by any of the methods described in Section A.4.4.1. A subroutine with arguments is recognised only within VBA an example is... [Pg.445]

At first it is easiest to save all subroutines and functions in a single module, but more experienced programmers can experiment with fairly sophisticated methods for organising and declaring procedures and variables. [Pg.445]

A variable declared locally within an always statement is also inferred as a latch if it is incompletely assigned in a conditional statement (if statement or case statement). This is shown in the following module. [Pg.60]

In module BistCell, each wire declared corresponded to a unique wire in the synthesized netlist. Not so with reg variable SI in module BistCellReg. Notice that the variable SI is used as a temporary in more than one place and does not represent one wire. The synthesized circuit still remains the same as that shown in Figure 3-1 however, the one-to-one mapping between the variables in the always statement and the nets in the synthesized netlist is not present. [Pg.109]

A subroutine can be Public or Private. Public subroutines can be called by any subroutine in any module. The default for any Sub procedure is Public. A Private subroutine can be called only by other subroutines in the same module. To declare the subroutine Tasks as a private subroutine, use the statement... [Pg.270]

Used at module level to declare lower bound for an array. Preserves data in an existing array when using ReDim. Indicates that the procedure is available to all other procedures. [Pg.418]

Used at module level to declare lower bound for an array. [Pg.433]

Can be Option Base 0 or 1. The statement can appear only once in a module and must precede all Dim or equivalent declaration. [Pg.433]

The key steps in prequalification are summarized in Fig. 1. Detailed descriptions of the different steps are given below. The preparatory steps of drafting a documentation system, including confidentiality agreements, declaration of conflict of interest, SOPs and guidelines, are described in Module 1. [Pg.232]

Marighetto A, Valerio S, Jaffard R et al (2008) The AMPA modulator S 18986 improves declarative and working memory performances in aged mice. Behav Pharmacol 19 235-244... [Pg.136]

Such problems with data transfer can be avoided by declaring the parameters involved as Public, in which case they are accessible throughout the entire VBA module. Public parameters must be declared at the very beginning of the module, in the format of a dimension statement, but with Public instead of Dim, as illustrated below. Note that, in this case, we can merely invoke the subroutine by stating its name, leaving out its brackets and, even, the instruction Call. [Pg.395]

ACT-R is composed of perceptual-motor and memory modules implemented as production rules. Both declarative and procedural memory are modeled. A pattern-matching mechanism is used to select production rules applicable to the situation. Buffers are used to interact with and represent the state of modules. ACT-R is implemented as a computer language. Users create a program containing relevant task data to model the task and task performance. An extension of ACT called SNIF-ACT that incorporates a Bayesian navigation mechanism was described earlier in this chapter (Fu and Pirolli 2007). [Pg.543]

For most products and machines, the self-declaration process (module A) is possible. In practice the manufacturer performs the complete product assessment according to EU standards, issues the declaration, and affixes the CE marking to the product. A technical file or documentation must also be available on demand for national enforcement authorities. Keep in mind that this is an internal self-assessment process, a do-it-yourself approach, that results in issuance of the manufacturer s declaration of conformity and the CE marking (Figure 2-6). The buyer may demand proof of safety/EMC compliance in the form of a mark, certificate, or test report from a European notified or competent body. [Pg.29]

Note. In all three cases, the CE marking, declaration, and technical file shall be in place. ISO 9000 factory quality techniques are not a part of modules A, Aa or B-C (see Product Quality versus Factory Quality in Chapter 5). The relevant safety/EMC directives and conformity assessment modules still apply. [Pg.31]

HDL Design Wizard is a GUI tool to help the designers visually declare the interfaces of an HDL module (in Verilog) and entity (in VHDL). Input, output or bidirectional ports are defined. [Pg.25]

The domain module represents what is being teached and contains usually a set of facts and/or rules representing the knowledge we have about the domain. Sometimes this part of the system is also responsible for the automatic generation of examples. A lot of attention has been paid to the problem of domain knowledge representation, the solutions ranging from declarative (frame-like) to procedural ones (production rules). [Pg.98]

Defining a COMSOL application mode consists of three parts the application mode selection with dependent variable declaration, the boundary settings, and the subdomain settings. In our case, the application mode is diffusion of dilute species from the chemical engineering module ... [Pg.300]


See other pages where Module declaration is mentioned: [Pg.113]    [Pg.75]    [Pg.43]    [Pg.376]    [Pg.84]    [Pg.613]    [Pg.203]    [Pg.14]    [Pg.35]    [Pg.258]    [Pg.105]    [Pg.204]    [Pg.276]    [Pg.217]    [Pg.2436]    [Pg.133]    [Pg.130]    [Pg.27]    [Pg.300]    [Pg.347]   
See also in sourсe #XX -- [ Pg.98 ]




SEARCH



Declaration

© 2024 chempedia.info