Mode Columns

In fact, every silica-based reversed phase represents a mixed-mode column, because besides the alkyl chains it has silanol groups, which are groups capable of weak cation exchange. Some C18 materials of the first generation, such as Partisil ODS from Whatman or Spherisorb ODSl from Waters, have only a very low carbon content ( 5%) and a high number of free silanol groups. With these [Pg.231]

In the earlier sections, we have discussed the options available to retain ionizable polar analytes. In the following, we show possibilities to retain and chromatograph neutral and ionizable analytes together. [Pg.232]


FIGURE l.l Hydrophobic interaction and reversed-phase chromatography (HIC-RPC). Two-dimensional separation of proteins and alkylbenzenes in consecutive HIC and RPC modes. Column 100 X 8 mm i.d. HIC mobile phase, gradient decreasing from 1.7 to 0 mol/liter ammonium sulfate in 0.02 mol/liter phosphate buffer solution (pH 7) in 15 min. RPC mobile phase, 0.02 mol/liter phosphate buffer solution (pH 7) acetonitrile (65 35 vol/vol) flow rate, I ml/min UV detection 254 nm. Peaks (I) cytochrome c, (2) ribonuclease A, (3) conalbumin, (4) lysozyme, (5) soybean trypsin inhibitor, (6) benzene, (7) toluene, (8) ethylbenzene, (9) propylbenzene, (10) butylbenzene, and (II) amylbenzene. [Reprinted from J. M. J. Frechet (1996). Pore-size specific modification as an approach to a separation media for single-column, two-dimensional HPLC, Am. Lab. 28, 18, p. 31. Copyright 1996 by International Scientific Communications, Inc.. Shelton, CT.]... [Pg.12]

Gas chromatograph Sample injector Injection port Injection mode Column... [Pg.1348]

Online detection using 4H nuclear magnetic resonance (NMR) is a detection mode that has become increasingly practical. In a recent application, cell culture supernatant was monitored on-line with 1-dimensional NMR for trehalose, P-D-pyranose, P-D-furanose, succinate, acetate and uridine.33 In stopped-flow mode, column fractions can also be analyzed by 2-D NMR. Reaction products of the preparation of the neuromuscular blocking compound atracurium besylate were separated on chiral HPLC and detected by 4H NMR.34 Ten isomeric peaks were separated on a cellulose-based phase and identified by online NMR in stopped-flow mode. [Pg.62]

Injection mode Column type Detection limit Advantages Disadvantages... [Pg.189]

Implementation of SFC has initially been hampered by instrumental problems, such as back-pressure regulation, need for syringe pumps, consistent flow-rates, pressure and density gradient control, modifier gradient elution, small volume injection (nL), poor reproducibility of injection, and miniaturised detection. These difficulties, which limited sensitivity, precision or reproducibility in industrial applications, were eventually overcome. Because instrumentation for SFC is quite complex and expensive, the technique is still not widely accepted. At the present time few SFC instrument manufacturers are active. Berger and Wilson [239] have described packed SFC instrumentation equipped with FID, UV/VIS and NPD, which can also be employed for open-tubular SFC in a pressure-control mode. Column technology has been largely borrowed from GC (for the open-tubular format) or from HPLC (for the packed format). Open-tubular coated capillaries (50-100 irn i.d.), packed capillaries (100-500 p,m i.d.), and packed columns (1 -4.6 mm i.d.) have been used for SFC (Table 4.27). [Pg.206]

Fig.4 Reconstructed SRM chromatograms obtained from the LC-ESI-MS/MS analysis of a 100 ng mL-1 standard mixture of estrogens (in the NI mode) and progestogens (in the PI mode). Column Purospher STAR RP-18e (125x2 mm, 5 pm, Merck). Mobile phase gradient acetonitrile/water. Flow rate 0.2 mL min-1... Fig.4 Reconstructed SRM chromatograms obtained from the LC-ESI-MS/MS analysis of a 100 ng mL-1 standard mixture of estrogens (in the NI mode) and progestogens (in the PI mode). Column Purospher STAR RP-18e (125x2 mm, 5 pm, Merck). Mobile phase gradient acetonitrile/water. Flow rate 0.2 mL min-1...
Chromatographic Mode Column Usage (%) (1982-83) Column Usage (%) (1980-81)... [Pg.125]

Fig. 14. Chromatograms of poly (diethylene glycol adipate) (M 700) of different functionality, obtained in the exclusion separation mode. (Column Si-100, eluent methylethyl ketone, u = 1 ml/min, volume of the sample 10 pi, refractometer, t = 24 UC)... Fig. 14. Chromatograms of poly (diethylene glycol adipate) (M 700) of different functionality, obtained in the exclusion separation mode. (Column Si-100, eluent methylethyl ketone, u = 1 ml/min, volume of the sample 10 pi, refractometer, t = 24 UC)...
The combination of solid-phase extraction (SPE) with HPLC analysis or preparative HPLC can be a valuable tool in concentrating and identifying degradation products. SPE can be a useful technique for the isolation and concentration of analytes from a complex mixture. Selection of the appropriate column depends on the properties of the API and the suspected degradants (70,71). Mixed mode columns having both non-polar and ion... [Pg.437]

Another important environmental and forensic application is the identification of explosives and their degradation products. A method based on liquid chromatography was unable to produce baseline resolution of 14 nitroaromatic and nitramine explosive compounds. The problem was solved as Bailey et al. tested the separation of the same mixture in CEC mode (column packed with 1.5-pm C18 silica) [89]. A baseline resolution of all 14 compounds was realized in 7 min in a second run, performed in less than 2 min, only 2 analytes of 14 co-eluted. To stabilize EOF and reduce peak tailing, SDS was added to the mobile phase. As in previous surfactant-mediated studies mentioned, changes in the elution order of the compounds were observed, suggesting a more complex separation mechanism (Figure 18, from Ref. 89). [Pg.380]

Reviews of various preconcentration methods have been given by Kirkland and Frei .Kirk-land et al. investigated peak broadening caused by the injection mode, column design, detectors and guard columns. [Pg.232]

Reversed phase, normal phase, ion exchange, drug columns, mixed-mode columns, oil and grease vacuum manifold and accessories, 96-Well format. [Pg.336]

F. Mashige, Y. Matsushima, C. Miyata, R. Yamada, H. Kanazawa, I. Sakuma, N. Takai, N. Shinozuka, A. Ohkubo and K. Nakahara, Simultaneous determination of catecholamines, their basic metabolites and serotonin in urine by high-performance liquid chromatography using a mixed-mode column and an eight-channel electrochemical detector, Biomed. Chromatogr, 9, 221-225 (1995). [Pg.122]

Offsets may also be constant across the second mode (columns) as shown in Figure 9.4. The underlying bilinear model with offsets across the second mode reads... [Pg.222]

HPLC Separation Modes, Column-Packing Materials, and Solvents... [Pg.166]

Walshe, M. Kelly, M.T. Smyth, M.R. Ritchie, H. Retention studies on mixed-mode columns in high-performance liquid chromatography. J.Chromatogr.A, 1995, 708, 31-40... [Pg.79]


See other pages where Mode Columns is mentioned: [Pg.72]    [Pg.72]    [Pg.1304]    [Pg.1348]    [Pg.1349]    [Pg.445]    [Pg.166]    [Pg.266]    [Pg.29]    [Pg.241]    [Pg.456]    [Pg.226]    [Pg.396]    [Pg.33]    [Pg.139]    [Pg.979]    [Pg.152]    [Pg.153]    [Pg.113]    [Pg.389]    [Pg.240]    [Pg.158]    [Pg.168]    [Pg.657]    [Pg.657]    [Pg.1069]    [Pg.234]    [Pg.497]    [Pg.498]    [Pg.283]    [Pg.225]    [Pg.250]    [Pg.332]   


SEARCH



Acclaim Mixed-Mode silica columns

Chromatographic Modes of Column Separation

Chromatographic modes, column types

Column separation, modes

HPLC columns modes

Mixed-mode columns

Polymer-Based Mixed-Mode Columns

Separator Acclaim Mixed-Mode silica columns

Silica-Based Mixed-Mode Columns

© 2024 chempedia.info