Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Micro volume

A variation on depth profiling that can be performed by modern scanning Auger instruments (see Sect. 2.2.6) is to program the incident electron beam to jump from one pre-selected position on a surface to each of many others in turn, with multiplexing at each position. This is called multiple point analysis. Sets of elemental maps acquired after each sputtering step or each period of continuous sputtering can be related to each other in a computer frame-store system to derive a three-dimensional analysis of a selected micro volume. [Pg.42]

Carlsson, K. and Karlberg, N. Determination of octanol-water partition coefficients using a micro-volume liquid-liquid flow extraction system. Anal. Chim. Acta, 423(1) 137-144, 2000. [Pg.1640]

Sample and reagent volumes can be varied from 0—95 ql in 0.1 ql increments while larger volumes can be varied in 1 ql increments from 0—370 ql. These micro-volume... [Pg.39]

For Nitinol - at the transition Ms, atoms begins to shear uniformly throughout the crystal. As the temperature is lowered the atomic shear continues to increase. At temperature, Mf, the atoms shear to their maximum point and assume a new structure. Thus, between Ms and Mr temperature interval the crystal structure of Nitinol is undefined and belongs neither to austenite nor to martensite . Therefore, thermodynamically, it should be classified as the second-order transformation. This is illustrated in Fig. 3. Conventionally - above Ms temperature, the whole crystal assume a crystal structure identified as austenite . At Ms temperature, a new crystal structure of martensite begins to form through two-dimensional (planar) atomic shear. The two crystal structures of austenite and martensite therefore share an identical plane known as Invariant Plane. As the temperature is lowered, the two dimensional shear (or more correctly, shift ) continue to take place one plane at a time such that the Invariant Plane moves in the direction as to increase the volume of martensite at the expense of austenite . Ultimately, at Mt temperature the whole crystal becomes martensite . Since between Ms and Mf any given micro-volume of the crystal must belong to either the austenite or the martensite , the transformation is of the first-order thermodynamically. This case is pictorially illustrated in Fig. 4. [Pg.111]

Microfabrication is increasingly central to modern science and technology. Many opportunities in technology derive from the ability to fabricate new types of microstructures or to reconstitute existing structures in down-sized versions. The most obvious examples are in microelectronics. Microstructures should also provide the opportunity to study basic scientific phenomena that occur at small dimensions one example is quantum confinement observed in nanostructures [1]. Although microfabrication has its basis in microelectronics and most research in microfabrication has been focused on microelectronic devices [2], applications in other areas are rapidly emerging. These include systems for microanalysis [3-6], micro-volume reactors [7,8], combinatorial synthesis [9], micro electromechanical systems (MEMS) [10, 11], and optical components [12-14]. [Pg.2]

In Vivo Test of the Infusion Device. Before the infusion device was used to deliver micro-volume of a heparin solution, the amount of the anticoagulant required to delay the normal clotting time from 1.02 min to > 15 min was determined. An intraperitoneal silicone catheter was inserted by way of a trocar needle into an anesthetized Wistar rat, and the external catheter end was connected to the flow rate testing assembly. With a glass hollow fibre flow moderator having a flow rate of 50 plitre/hr at 48 kPa driving pressure, it was found to require about 25 IU/kg/hr to obtain a Lee-White... [Pg.348]

Ancillaries include a micro-volume module, a hazardous fluid module and a dry powder module. Their small volume module uses less than 125 ml of diluent. The micro volume module has a total volume of 12 ml this has an internal stirring mechanism to keep particles suspended during analyses. The automatic hazardous fluids module can be supplied with a microtip eight power ultrasonic probe to keep the particles dispersed. The dry powder module analyzes both free flowing and cohesive powders covering the size range from 0.375 pm to 2000 pm. [Pg.555]

To introduce a micro-volume of sample, which must not exceed 1 per cent of the effective length of the capillary in order to protect the resolution, two procedures are used ... [Pg.152]

The temperature of the plasma varies from 2000 to 9000 K, depending on the position. By comparison, the flames used in FES are relatively cold sources. Micro-volumes of sample solutions are introduced at a constant flow with a pneumatic nebulizer via a third tube of small diameter directly into the inductively coupled plasma. The position in the plasma chosen for the measurement of light emission (either radial or axial), depends upon the element and whether an ionic or atomic spectral line is selected for the measurement. [Pg.313]

The bead injection system was designed to operate in the sequential injection mode. It is possible to carry out bead injection analysis in a low-cost flow injection system with a unidirectional pump and without a computer, mainly for applications where samples and reagents are abundant and when there is no need for micro-volume control. To this end, it is necessary to use a flow cell able to achieve bead retention, accommodation of chemical reactions and detection [87,88]. [Pg.25]

These can be used for both macro and micro volume measurements. The calibration marks on the syringes may not be very accurate, but the reproducibility can be excellent if an automatic deliverer is used, such as a spring-load device that... [Pg.33]

Fig. 3.4 a, b. Possible two-dimensional structures for critical ionic nuclei, a, the nucleus resembles a micro-volume of the bulk crystalline phase b, the nucleus contains weakly bonded Ions in a diffuse, highly solvated structure ... [Pg.137]

Biology can overcome this problem of matrix/vesicle geometry by maintaining the matrix in free solution within the vesicle or by constructing elongated vesicles. In both cases epitaxis can occur since the substrate is presented as a two-dimensional plane rather than as a curved surface. It seems however, unlikely that the intravesicular matrix could be maintained in a static state in free solution within such a micro-volume of space. [Pg.167]

The dissociation constant, p Tg, controls the pH effect of the retention of ionizable compounds. Dissociation constants are measured by titration, and micro-volume flow titration has been developed. Dissociation constants can also be predicted from the atomic partial charge. An extended study of dissociation constants has been carried out, and a new method was proposed similar to a modified Hammett s equation. The dissociation constants used in this book were predicted by this new method from the atomic partial charge. ... [Pg.18]

R. Marrington, T. R. Dafforn, D. J. Halsall, and A. Rodger, Micro-volume Couette flow sample orientation for absorbance and fluorescence linear dichroism, Biophys.J. 87[3], 2002-2012 [2004],... [Pg.398]

It is impossible to create an isothermal process in plug flow reactors as it requires the variation of thermal transfei along the reactor length, according to the kinetics of heat emission. Therefore, plug flow reactors run under adiabatic conditions or at least imder nonisothermal mode conditions with external heat removal. The heat balance equation for steady state conditions for the micro volume of a reactor can be written in the form [4] ... [Pg.246]


See other pages where Micro volume is mentioned: [Pg.68]    [Pg.60]    [Pg.239]    [Pg.66]    [Pg.77]    [Pg.47]    [Pg.344]    [Pg.347]    [Pg.546]    [Pg.484]    [Pg.255]    [Pg.506]    [Pg.181]    [Pg.224]    [Pg.1049]    [Pg.94]    [Pg.290]    [Pg.192]    [Pg.256]    [Pg.65]    [Pg.76]    [Pg.3]    [Pg.289]    [Pg.1081]    [Pg.429]    [Pg.8]    [Pg.430]    [Pg.91]    [Pg.383]    [Pg.110]    [Pg.167]    [Pg.167]   
See also in sourсe #XX -- [ Pg.154 ]




SEARCH



Capillary volume, micro

Column volume, micro

Micro volume control

Micro-pores volume

© 2024 chempedia.info