Flow moderation

Colloid mill Continuous Laminar flow Moderate... [Pg.201]

Preparation of Glass Hollow Fibre for Flow Moderation. A 0.5 cm mid-section of a blood collecting glass capillary (4 cm long I.D. 0.25 mm) was heated over a small alcohol burner. [Pg.342]

The proximate end of the tubing emerging from the flexible metal coil protector affixed to the harness was connected to a hollow fibre flow moderator with a rate of 50 plitre/hr at 48 kPa pressure. The Viaflex container was filled with 30 ml of... [Pg.344]

To avoid flow decay, the inclusion of a 0.22-micron porosity filter unit (diameter 2.5 cm) between the exit port of the drug solution bag and the flow moderator may help to eliminate any invisible suspension in the solution which can clog the fine channel of the flow moderator. [Pg.347]

Infusion Device Flow Rate. The example given in Table II shows that the flow rate with 4 aligned nylon fibre flow moderators in series is essentially constant up to 200 mL of... [Pg.347]

In Vivo Test of the Infusion Device. Before the infusion device was used to deliver micro-volume of a heparin solution, the amount of the anticoagulant required to delay the normal clotting time from 1.02 min to > 15 min was determined. An intraperitoneal silicone catheter was inserted by way of a trocar needle into an anesthetized Wistar rat, and the external catheter end was connected to the flow rate testing assembly. With a glass hollow fibre flow moderator having a flow rate of 50 plitre/hr at 48 kPa driving pressure, it was found to require about 25 IU/kg/hr to obtain a Lee-White... [Pg.348]

The infusion device described in this report can be fabricated in a few hours with materials usually available in a laboratory. For high flow, the aligned nylon fibre flow moderator can be used. When microvolume delivery is required, the use of the hollow fibre flow moderator can be considered. As for the infusion enclosures, the transparent material was specially chosen to allow visualization of the internal contents of the drug solution bag, which is always inspected at regualr intervals during use for the presence of particulate suspension or air bubbles that may develop and be harmful. [Pg.349]

Flow moderator a stainless steel, open-ended tube with a plastic end-cap, which serves as a pathway for the exit of drug solution/ suspension. [Pg.98]

In this process, water crosses the outer semi-permeable membrane of the pump. The characteristics of the semipermeable membrane including permeability, pore size, and thickness are key factors determining the rate at which water molecules enter the osmotic sleeve. The water that is drawn across the semipermeable membrane causes the osmotic chamber to expand. This force compresses the flexible drug reservoir, discharging the drag solution through the flow moderator. [Pg.98]

Continuum flow Slip-flow (slightly rarefied) Transition flow (moderately rarefied) Free-molecular flow (highly rarefied)... [Pg.17]

Hydralazine (Apresoline) Directly relaxes arterioles (not veins) independent of sympathetic interactions. Causes decrease in blood pressure leading to reflex tachycardia and increased cardiac output. Directly increases renal blood flow. Moderate hypertension. May be used in pregnant women who are hypertensive. Reflex tachycardia, palpitations, fluid retention, systemic lupus erythematosis-liKe syndrome. Chronic therapy may lead to peripheral neuritis (due to interference with vitamin B6 metabolism in neural tissue). [Pg.72]

Figure 5.19 Temperature profiles for a tubular reactor with jacket cooling (a) Parallel flow, high coolant rate (b) parallel flow, moderate coolant rate (c) counter-current flow, moderate coolant rate. [Pg.219]

An oral/intravenous pharmacokinetic study in rats indicated low clearance (21% liver blood flow), moderate volume of distribution, and good systemic exposure. The limited oral bioavailability and brain penetration observed in this study provided a platform for further optimization, with good molecular properties and a PSA below 70. However, a suitable compound from further development would require increased potency, solubility, and a clear hERG profile. [Pg.212]

P. Wilson and P. Hu, Reactor Analysis for Counter-flowing Moderator and Coolant in a Supercritical Water Reactor, Proc. ICONE-14, July 17-20, 2006, Miami, FL, ICONE14-89392 (2006)... [Pg.596]

Figure 6. ALZET osmotic minipump with flow moderator. (Copyright 1980 ALZA Corp.)... Figure 6. ALZET osmotic minipump with flow moderator. (Copyright 1980 ALZA Corp.)...
The flow moderator is then inserted through the portal, to restrict the diffusional mode of solute exit, assuring that the osmotic process will control the delivery rate. If the transparent overcap is removed from the flow moderator, a catheter (PE 50 or 60 size) can be attached for localized administration of drugs to areas remote from the site of implantation or to target organs. [Pg.305]


See other pages where Flow moderation is mentioned: [Pg.144]    [Pg.415]    [Pg.341]    [Pg.342]    [Pg.343]    [Pg.344]    [Pg.346]    [Pg.347]    [Pg.349]    [Pg.144]    [Pg.460]    [Pg.1093]    [Pg.1095]    [Pg.144]    [Pg.144]    [Pg.160]    [Pg.433]    [Pg.64]    [Pg.291]    [Pg.3044]    [Pg.15]    [Pg.160]   
See also in sourсe #XX -- [ Pg.342 ]