Matrix standards, uses

In 1978, Ho et al. [33] published an algorithm for rank annihilation factor analysis. The procedure requires two bilinear data sets, a calibration standard set Xj and a sample set X . The calibration set is obtained by measuring a standard mixture which contains known amounts of the analytes of interest. The sample set contains the measurements of the sample in which the analytes have to be quantified. Let us assume that we are only interested in one analyte. By a PCA we obtain the rank R of the data matrix X which is theoretically equal to 1 + n, where rt is the number of interfering compounds. Because the calibration set contains only one compound, its rank R is equal to one. [Pg.298]

From now on, we adopt a notation that reflects the chemical nature of the data, rather than the statistical nature. Let us assume one attempts to analyze a solution containing p components using UV-VIS transmission spectroscopy. There are n calibration samples ( standards ), hence n spectra. The spectra are recorded at q wavelengths ( sensors ), digitized and collected in an nx.q matrix S. The information on the known concentrations of the chemical constituents in the calibration set is stored in an nxp matrix C. Each column of C contains the concentrations of one of the p analytes, each row the concentrations of the analytes for a particular calibration standard. [Pg.353]

Other ways to minimize matrix effects include improving the sample cleanup, diluting the sample, using labeled internal standards, using standard addition, or using matrix-matched standards. The last approach, however, is not permitted for enforcement methods at present by the US EPA or the US Pood and Drug Administration... [Pg.780]

Brandt [200] has extracted tri(nonylphenyl) phosphite (TNPP) from a styrene-butadiene polymer using iso-octane. Brown [211] has reported US extraction of acrylic acid monomer from polyacrylates. Ultrasonication was also shown to be a fast and efficient extraction method for organophosphate ester flame retardants and plasticisers [212]. Greenpeace [213] has recently reported the concentration of phthalate esters in 72 toys (mostly made in China) using shaking and sonication extraction methods. Extraction and analytical procedures were carefully quality controlled. QC procedures and acceptance criteria were based on USEPA method 606 for the analysis of phthalates in water samples [214]. Extraction efficiency was tested by spiking blank matrix and by standard addition to phthalate-containing samples. For removal of fatty acids from the surface of EVA pellets a lmin ultrasonic bath treatment in isopropanol is sufficient [215]. It has been noticed that the experimental ultrasonic extraction conditions are often ill defined and do not allow independent verification. [Pg.80]

Let us consider the simple case of the H atom and its variational approximation at the standard HF/3-21G level, for which we can follow a few of the steps in terms of corresponding density-matrix manipulations. After symmetrically orthogonalizing the two basis orbitals of the 3-21G set to obtain orthonormal basis functions A s and dA, we obtain the corresponding AO form of the density operator (i.e., the 2 x 2 matrix representation of y in the... [Pg.23]

The eigenvalue/eigenvector decomposition of the covariance matrix thus allows us to redefine the problem in terms of Nc independent, standard normal random variables 0in. [Pg.239]

A standard addition is a known quantity of analyte added to an unknown to increase the concentration of analyte. Standard additions are especially useful when matrix effects are important. A matrix effect is a change in the analytical signal caused by anything in the sample other than analyte. You should be able to use Equation 5-7 to compute the quantity of analyte in a standard addition experiment. Equation 5-9 is used with multiple standard additions to construct the graph in Figure 5-6, in which the jc-intercept gives us the concentration of analyte. [Pg.92]

A square and full rank matrix A can be inverted by row reduction of the multiple augmented matrix ( A In ) where In is the n by n identity matrix comprised of the n standard unit vectors e R" as its columns. If this row reduction is carried out until the identity matrix In appears in the left half of ( /, A-1 ), the right half gives us the matrix inverse A-1 with A-1 A = In = AA L... [Pg.539]

Let us begin with the ISO definition [9] A calibration is a set of operations that establish, under specified conditions, the relationship between values of quantities indicated by a measuring instrument or measuring system, or values represented by a material measure or reference material, and the corresponding values realized by standards. Applied to amount measurements, the standards would then be the values assigned to the RMs (of defined composition) at the stated uncertainty relative to the true value of the property, expressed in SI units, or relative to an internationally recognized, certified standard RM for the relevant property, range, and matrix composition. [Pg.7]

More than 220 producers of CRMs throughout the world produce today 12,000 20,000 materials with dif ferent matrixes, analytes and properties [4]. However, many testing (analytical) laboratories cannot find suitable CRMs in the market and develop in-house reference materials (IHRMs) themselves. Often IHRMs are developed in a laboratory to conserve the corresponding expensive CRMs. For example, a pharmaceutical company Chemagis Ltd. produces 30 active pharmaceutical ingredients steroids, benzodiazepines, antihistamines, hipolipidaemics, blood flow reactants, etc. Only for a few of them Mo-metasone Furoate, Fluticasone Propionate and Dobutamine Hydrochloride are of fi-cial reference standards for assay supplied by US, British and European Pharmacopoeias with prices of about 180 per unit (50 200 mg). Thus, to support its customers Chemagis is forced to develop IHRMs for assay as well as for impurities and related substances of each produced compound. Therefore, certification of such IHRMs that leads to traceable values is very important. [Pg.269]

The most common calibration method is to prepare standards of known concentrations, covering the concentration range expected in the sample. The matrix of the standard should be as close to the samples as possible. For instance, if the sample is to be extracted into a certain organic solvent, the standards should be prepared in the same solvent. The calibration curve is a plot of detector response as a function of concentration. A typical calibration curve is shown in Figure 1.3. It is used to determine the amount of analyte in the unknown samples. The calibration can be done in two ways, best illustrated by an example. Let us say that the amount of lead in soil is being measured. The analytical method includes sample preparation by acid extraction followed by analysis using atomic absorption (AA). The stan-... [Pg.5]

In order to find extrema of E( ui ), subject to the normalization condition, standard moves known as the Lagrange multipliers method are applied, which readily lead us to the well-known form of the generalized matrix eigenvalue/eigenvector problem ... [Pg.18]

The catalyst used in this study is a model FCC catalyst with composition zeolite US-Y (30%), silica hinder (25%), kaolin (25%) and pseudo boehmite alumina matrix (20%)-Hexadecane was used as feedstock and in the catalyst poisoning studies 10% by volume quinoline or phenanthrene were added to the hexadecane. Reactivity and coking were determined using a standard MAT reactor test (6). [Pg.378]

A second generation lens, the Transitions Plus lens, was introduced in November 1992. In the years since, Transitions Optical has marketed a succession of new lenses. In September 1994 the EuroBrown lens appeared, formulated to give when activated a brown color, especially favored in the European market. The mid-index Transitions III lenses were launched in the United States and in Europe during 1996, and the Transitions XTRActive lenses were introduced in the US in January 1997. The most recently introduced lenses are Transitions III lenses in a standard index matrix. These use the latest technology in organic photochromic dyestuffs and polymer science and engineering, and maintain the company s position... [Pg.384]

The smoothness of algebraic matrix groups is a property not shared by all closed sets in /c". To see what it means, take fc = fc and let 5 fc" be an arbitrary irreducible closed set. Let s be a point in S corresponding to the maximal ideal J in k[S]. If S is smooth, n si k = O si /J us) has fc-dimension equal to the dimension of S. (This would in general be called smoothness at s.) If S is defined by equations fj = 0, the generators and relations for OUS] show that S is smooth at s iff the matrix of partial derivatives (dfj/dXi)(s) has rank n — dim V. Over the real or complex field this is the standard Jacobian criterion for the solutions of the system (f = 0) to form a C or analytic submanifold near s. For S to be smooth means then that it has no cusps or self-crossings or other singularities . [Pg.99]

Military Standardization Handbook 17, Polymer Matrix Composites Guidelines, MIL-HDBK17B, Vol. 1, 1988 Plastics for Aerospace Vehicles, Part I. Reinforced Plastics, MIL HDBK17A, 1971, US Department of Defense, Washington, DC. [Pg.413]


See other pages where Matrix standards, uses is mentioned: [Pg.16]    [Pg.273]    [Pg.39]    [Pg.1328]    [Pg.220]    [Pg.70]    [Pg.111]    [Pg.107]    [Pg.124]    [Pg.307]    [Pg.240]    [Pg.292]    [Pg.188]    [Pg.413]    [Pg.25]    [Pg.225]    [Pg.99]    [Pg.35]    [Pg.305]    [Pg.291]    [Pg.381]    [Pg.153]    [Pg.76]    [Pg.312]    [Pg.6]    [Pg.488]    [Pg.1328]    [Pg.129]    [Pg.126]    [Pg.140]    [Pg.129]    [Pg.347]    [Pg.54]    [Pg.91]    [Pg.139]   