Mass spectroscopy detection limit

The section on Spectroscopy has been expanded to include ultraviolet-visible spectroscopy, fluorescence, Raman spectroscopy, and mass spectroscopy. Retained sections have been thoroughly revised in particular, the tables on electronic emission and atomic absorption spectroscopy, nuclear magnetic resonance, and infrared spectroscopy. Detection limits are listed for the elements when using flame emission, flame atomic absorption, electrothermal atomic absorption, argon ICP, and flame atomic fluorescence. Nuclear magnetic resonance embraces tables for the nuclear properties of the elements, proton chemical shifts and coupling constants, and similar material for carbon-13, boron-11, nitrogen-15, fluorine-19, silicon-29, and phosphorus-31. [Pg.1287]

Carboxylic acids The smallest carboxylic acid, formic acid, can be measured using infrared spectroscopy (Table 11.2), since it has characteristic absorption bands. As discussed earlier and seen in Fig. 11.33b, mass spectrometry with chemical ionization using SiF5 also revealed HCOOH in an indoor environment (Huey et al., 1998). However, since the sensitivity in these initial studies was about two orders of magnitude less than that for HN03, the detection limit may be about the same as that for FTIR and TDLS. Formic and acetic acids have been monitored continuously from aircraft (Chapman et al., 1995) and their surface flux determined by eddy correlation (Shaw et al., 1998) using atmospheric pressure ionization mass spectrometry. Detection limits are about 30 ppt. [Pg.594]

Spark Source Mass Spectroscopy electrodes spark produces ions mass spectrometer detection limit 0.01-0.05 ppm ... [Pg.1946]

Glow Discharge Mass Spectroscopy for a D.C. glow discharge ionized in plasma mass spectrometer detection limit sub-ppb ... [Pg.1946]

Laser ionization mass spectrometry or laser microprobing (LIMS) is a microanalyt-ical technique used to rapidly characterize the elemental and, sometimes, molecular composition of materials. It is based on the ability of short high-power laser pulses (-10 ns) to produce ions from solids. The ions formed in these brief pulses are analyzed using a time-of-flight mass spectrometer. The quasi-simultaneous collection of all ion masses allows the survey analysis of unknown materials. The main applications of LIMS are in failure analysis, where chemical differences between a contaminated sample and a control need to be rapidly assessed. The ability to focus the laser beam to a diameter of approximately 1 mm permits the application of this technique to the characterization of small features, for example, in integrated circuits. The LIMS detection limits for many elements are close to 10 at/cm, which makes this technique considerably more sensitive than other survey microan-alytical techniques, such as Auger Electron Spectroscopy (AES) or Electron Probe Microanalysis (EPMA). Additionally, LIMS can be used to analyze insulating sam-... [Pg.586]

The material evaporated by the laser pulse is representative of the composition of the solid, however the ion signals that are actually measured by the mass spectrometer must be interpreted in the light of different ionization efficiencies. A comprehensive model for ion formation from solids under typical LIMS conditions does not exist, but we are able to estimate that under high laser irradiance conditions (>10 W/cm ) the detection limits vary from approximately 1 ppm atomic for easily ionized elements (such as the alkalis, in positive-ion spectroscopy, or the halogens, in negative-ion spectroscopy) to 100—200 ppm atomic for elements with poor ion yields (for example, Zn or As). [Pg.587]

As for silicon, secondary ion mass spectrometry (SIMS) is the most widely used profiling analysis technique for deuterium diffusion studies in III-V compounds. Deuterium advantageously replaces hydrogen for lowering the detection limit. The investigations of donor and acceptor neutralization effects have been usually performed through electrical measurements, low temperature photoluminescence, photothermal ionization spectroscopy (PTIS) and infrared absorption spectroscopy. These spectroscopic investigations will be treated in a separated part of this chapter. [Pg.465]

If reaction (2-13) follows reaction (2-12) instantaneously, the effect will not be noticeable in the H2 signal [12]. In spite of these limitations, we conclude that TPS with mass spectrometric detection is a highly useful technique for studying the sulfidation of hydrotreating catalysts. We shall return to the sulfidation of molybdenum oxides in the chapters on photoemission (Chapter 3), ion spectroscopy (Chapter 4), and in a case study on hydrodesulfurization catalysts in Chapter 9. [Pg.36]

The major anions and cations in seawater have a significant influence on most analytical protocols used to determine trace metals at low concentrations, so production of reference materials in seawater is absolutely essential. The major ions interfere strongly with metal analysis using graphite furnace atomic absorption spectroscopy (GFAAS) and inductively coupled plasma mass spectroscopy (ICP-MS) and must be eliminated. Consequently, preconcentration techniques used to lower detection limits must also exclude these elements. Techniques based on solvent extraction of hydrophobic chelates and column preconcentration using Chelex 100 achieve these objectives and have been widely used with GFAAS. [Pg.50]

In general, gas chromatography will undoubtedly continue to be the method of choice for characterization of light hydrocarbon materials. New and improved detection devices and techniques, such as chemiluminescence, atomic emission, and mass spectroscopy, will enhance selectivity, detection limits, and analytical productivity. Laboratory automation through autosampling, computer control, and data handling will provide improved precision and productivity, as well as simplified method operation. [Pg.252]

A major consequence of using regulatory limits based on degradant formation, rather than absolute change of the API level in the drug product, is that it necessitates the application and routine use of very sensitive analytical techniques [ 10]. In addition, the need to resolve both structurally similar, as well as structurally diverse degradants of the API, mandates the use of analytical separation techniques, for example, HPLC, CE, often coupled with highly sensitive detection modes, for example, ultraviolet (UV) spectroscopy, fluorescence (F) spectroscopy, electrochemical detection (EC), mass spectroscopy (MS), tandem mass spectroscopy (MS-MS) and so forth. [Pg.23]

In 1C, the election-detection mode is the one based on conductivity measurements of solutions in which the ionic load of the eluent is low, either due to the use of eluents of low specific conductivity, or due to the chemical suppression of the eluent conductivity achieved by proper devices (see further). Nevertheless, there are applications in which this kind of detection is not applicable, e.g., for species with low specific conductivity or for species (metals) that can precipitate during the classical detection with suppression. Among the techniques that can be used as an alternative to conductometric detection, spectrophotometry, amperometry, and spectroscopy (atomic absorption, AA, atomic emission, AE) or spectrometry (inductively coupled plasma-mass spectrometry, ICP-MS, and MS) are those most widely used. Hence, the wide number of techniques available, together with the improvement of stationary phase technology, makes it possible to widen the spectrum of substances analyzable by 1C and to achieve extremely low detection limits. [Pg.406]

Li or a Li compound in the flame gives a bright crimson color due to its emission of670.8 nm photons produced by the short-lived species LiOH. This is the property that allows for the spectrophotometric determination of Li by atomic absorption spectroscopy (AAS) down to 20 ppb. Inductively-coupled plasma emission spectroscopy (ICPAES), inductively-coupled plasma mass spectroscopy (ICPMS), and ion chromatography (IC) improve this limit to about 0.1 ppb. A spot test for detection of Li down to 2 ppm is provided by basic KIO4 plus FeCl3. [Pg.102]

Actinide metal samples are characterized by chemical and structure analysis. Multielement analysis by spark source mass spectrometry (SSMS) or inductively coupled argon plasma (ICAP) emission spectroscopy have lowered the detection limit for metallic impurities by 10 within the last two decades. The analysis of O, N, H by vacuum fusion requires large sample, but does not distinguish between bulk and surface of the material. Advanced techniques for surface analysis are being adapted for investigation of radioactive samples (Fig. 11) ... [Pg.70]


See other pages where Mass spectroscopy detection limit is mentioned: [Pg.442]    [Pg.1946]    [Pg.2080]    [Pg.295]    [Pg.356]    [Pg.604]    [Pg.606]    [Pg.612]    [Pg.625]    [Pg.235]    [Pg.536]    [Pg.317]    [Pg.259]    [Pg.677]    [Pg.93]    [Pg.434]    [Pg.577]    [Pg.231]    [Pg.16]    [Pg.325]    [Pg.88]    [Pg.310]    [Pg.347]    [Pg.49]    [Pg.15]    [Pg.570]    [Pg.38]    [Pg.180]    [Pg.17]    [Pg.174]    [Pg.155]    [Pg.39]   
See also in sourсe #XX -- [ Pg.351 ]




SEARCH



Detectable limit

Detection limits

Detection limits, limitations

Detection spectroscopy

Detection-limiting

Mass detection limits

Mass limit

Mass limitation

Mass spectroscopy

Spectroscopy detection limits

Spectroscopy limitations

Spectroscopy limited