Glow discharge mass spectroscopy

Table 4 Bias Corrected Isotope Ratio Measurements in the Unspiked Sample, Isotopically Enriched Spike, and Spiked Sample for Three Oil Leachate Samples as Determined by Glow Discharge Mass Spectroscopy Solution Residue Method... Table 4 Bias Corrected Isotope Ratio Measurements in the Unspiked Sample, Isotopically Enriched Spike, and Spiked Sample for Three Oil Leachate Samples as Determined by Glow Discharge Mass Spectroscopy Solution Residue Method...
Glow discharge mass spectroscopy (GDMS) - See Techniques for Materials Characterization, page 12-1. [Pg.105]

GDMS Glow Discharge Mass Spectroscopy Sample forms the cathode for a D.C. glow discharge Sputtered atoms ionized in plasma Ions - analyzed in mass spectrometer 0.1-100 pm 3-4 mm (Bulk) trace element analysis deleclion limit sub-ppb 9,10... [Pg.1967]

Glow Discharge Mass Spectroscopy for a D.C. glow discharge ionized in plasma mass spectrometer detection limit sub-ppb ... [Pg.1946]

There are several MS-based techniques that can provide chemical information for thin and thick layers [12]. For very thin layers (sub to 1-2 monolayers), nondestructive techniques such as static SIMS [13], ion scattering MS [14], or MS of recoiled ions [15] are suitable. These techniques are also the best adapted for examining surface contamination. They are all based on surface interactions of an ion beam with the solid surface. For depth profiling of thin and thick layers, MS is associated with a destructive source of neutrals or ions dynamic SIMS, secondary neutron mass spectroscopy (SNMS), glow discharge mass spectroscopy (GD-MS), matrix-enhanced SIMS, laser desorption/ionization MS, and desorption electrospray ionization (DESI) MS [16]. Ions are either desorbed from the solid surface or generated by postionization of neutrals sputtered off the surface. [Pg.944]

GDMS glow discharge mass spectroscopy Ido idose... [Pg.70]

Radio Frequency and Glow Discharge - Mass Spectroscopy... [Pg.48]

Shick and co-workers [132] and Aslanova and co-workers [151] used radio frequency and glow discharge - mass spectroscopy (GD-MS) for the characterisation of bulk polymers such as polytetrafluoroethylene (PTFE) - methyl vinyl ether and PTFE -hexafluoropropylene - polyvinylidene fluoride. [Pg.48]


See other pages where Glow discharge mass spectroscopy is mentioned: [Pg.85]    [Pg.80]    [Pg.580]    [Pg.90]    [Pg.950]    [Pg.81]    [Pg.104]    [Pg.94]    [Pg.90]    [Pg.104]    [Pg.80]    [Pg.132]   
See also in sourсe #XX -- [ Pg.178 ]




SEARCH



GLOW DISCHARGE SPECTROSCOPY

Glow

Glow discharge

Glow discharge mass spectroscopy GDMS)

Glow-Discharge Mass

Mass spectroscopy

Mass spectroscopy plasma/glow discharge

Radio frequency and glow discharge mass spectroscopy

© 2024 chempedia.info