Mass bubble column

K. H. Reichert and R. Michael, "Polymerization iu Bubble Columns, Problems of Mass and Heat Transfer at High SoHd Contents," Inst. Chem. [Pg.530]

Direct Chlorination of Ethylene. Direct chlorination of ethylene is generally conducted in Hquid EDC in a bubble column reactor. Ethylene and chlorine dissolve in the Hquid phase and combine in a homogeneous catalytic reaction to form EDC. Under typical process conditions, the reaction rate is controlled by mass transfer, with absorption of ethylene as the limiting factor (77). Ferric chloride is a highly selective and efficient catalyst for this reaction, and is widely used commercially (78). Ferric chloride and sodium chloride [7647-14-5] mixtures have also been utilized for the catalyst (79), as have tetrachloroferrate compounds, eg, ammonium tetrachloroferrate [24411-12-9] NH FeCl (80). The reaction most likely proceeds through an electrophilic addition mechanism, in which the catalyst first polarizes chlorine, as shown in equation 5. The polarized chlorine molecule then acts as an electrophilic reagent to attack the double bond of ethylene, thereby faciHtating chlorine addition (eq. 6) ... [Pg.417]

The choice of a bubble column or an agitated vessel depends primarily on the solubihty of the gas in the liquid, the corrosiveness of the liquid (often a gas compressor can be made of inexpensive material, whereas a mechanical agitator may have to be made of exotic, expensive materials), and the rate of chemical reac tion as compared with the mass-transfer rate. Bubble columns and agitated vessels are seldom used for gas absorption except in chemical reac tors. As a general rule. [Pg.1424]

Mass Transfer Mass transfer in plate and packed gas-liquid contactors has been covered earHer in this subsection. Attention nere will be limited to deep-bed contactors (bubble columns and agitated vessels). Theory underlying mass transfer between phases is discussed in Sec. 5 of this handbook. [Pg.1425]

Sada, E., Kumazawa, H., Lee, C. and Fujiwara, N., 1985. Gas-liquid mass transfer characteristics in a bubble column with suspended sparingly soluble fine particles. Industrial and Engineering Chemistry Process Design and Development, 24, 255-261. [Pg.321]

Hydrodynamics and mass transfer in bubble columns are dependent on the bubble size and the bubble velocity. As the bubble is released from the sparger, it comes into contact with media and microorganisms in the column. In sugar fermentation, glucose is converted to ethanol and carbon dioxide ... [Pg.294]

Only one publication on gas-liquid mass transfer in bubble-column slurry reactors has come to the author s attention. However, a relatively large volume of information regarding mass transfer between single bubbles or bubble swarms and pure liquid containing no suspended solids is available, and this information is probably of some relevance to the analysis of systems... [Pg.109]

It is concluded that gas bubble-columns exhibit mass-transfer rates of the same order of magnitude as packed columns at low liquid flow rates, and much higher mass-transfer rates at high liquid flow rates. The pressure drop across a bubble-column is much greater than that across packed columns of the same height. [Pg.111]

Among the more recent publications on mass transfer in bubble-columns, the following may be mentioned ... [Pg.112]

Yoshida and Akita (Yl) determined volumetric mass-transfer coefficients for the absorption of oxygen by aqueous sodium sulfite solutions in counter-current-ffow bubble-columns. Columns of various diameters (from 7.7 to 60.0 cm) and liquid heights (from 90 to 350 cm) were used in order to examine the effects of equipment size. The volumetric absorption coefficient reportedly increases with increasing gas velocity over the entire range investigated (up to approximately 30 cm/sec nominal velocity), and with increasing column diameter, but is independent of liquid height. These observations are somewhat at variance with those of other workers. [Pg.113]

Yoshitome et al. (Y2) examined mass transfer from single samples of benzoic acid suspended in an air-water bubble-column. Spherical, cylindrical, and disk-shaped samples of diameters from 25 to 75 mm were used,... [Pg.113]

The mass-transfer rates obtainable across the gas-liquid interface are of nearly the same magnitude in the different operations. Bubble-column slurries exhibit rather higher transfer rates than conventional packed columns... [Pg.130]

Owing to the high computational load, it is tempting to assume rotational symmetry to reduce to 2D simulations. However, the symmetrical axis is a wall in the simulations that allows slip but no transport across it. The flow in bubble columns or bubbling fluidized beds is never steady, but instead oscillates everywhere, including across the center of the reactor. Consequently, a 2D rotational symmetry representation is never accurate for these reactors. A second problem with axis symmetry is that the bubbles formed in a bubbling fluidized bed are simulated as toroids and the mass balance for the bubble will be problematic when the bubble moves in a radial direction. It is also problematic to calculate the void fraction with these models. [Pg.342]

Fig. 15. Reference floe diameter dp for bubble columns versus mass related adiabatic compressor power PJqV... Fig. 15. Reference floe diameter dp for bubble columns versus mass related adiabatic compressor power PJqV...
Fig. 26. Reference floe diameter of floe particle system versus mass transfer coefficient kpa for bubble columns with different gas spargers H = 1.08 m D = 0.4 m... Fig. 26. Reference floe diameter of floe particle system versus mass transfer coefficient kpa for bubble columns with different gas spargers H = 1.08 m D = 0.4 m...
Bubble columns and mechanically stirred reactors are the most common reactor types for slurry systems in laboratories, but they have many disadvantages from an industrialization perspective. Mechanically stirred reactors usually used for laboratorial studies are difficult to scale-up. In order to achieve good mixing and mass transfer between the gas and slurry phases, bubble column must be operated at a high space velocity, which leads to a relative low one-through conversion of the syngas. [Pg.490]

Airlift loop reactor (ALR), basically a specially structured bubble column, has been widely used in chemical industry, biotechnology and environmental protection, due to its high efficiency in mixing, mass transfer, heat transfer etc [1]. In these processes, multiple reactions are commonly involved, in addition to their complicated aspects of mixing, mass transfer, and heat transfer. The interaction of all these obviously affects selectivity of the desired products [2]. It is, therefore, essential to develop efficient computational flow models to reveal more about such a complicated process and to facilitate design and scale up tasks of the reactor. However, in the past decades, most involved studies were usually carried out in air-water system and the assumed reactor constructions were oversimplified which kept itself far away from the real industrial conditions [3] [4]. [Pg.525]

GL 22] [R 3] [R 9] [R 10] [P 23] The mass transfer efficiency of different gas/liquid contactors as a function of residence time was compared qualitatively (Figure 5.29), including an interdigital micro mixer, a caterpillar mini mixer, a mixing tee and three micro bubble columns using micro channels of varying diameter [5]. [Pg.639]

The parameter p (= 7(5 ) in gas-liquid sy.stems plays the same role as V/Aex in catalytic reactions. This parameter amounts to 10-40 for a gas and liquid in film contact, and increases to lO -lO" for gas bubbles dispersed in a liquid. If the Hatta number (see section 5.4.3) is low (below I) this indicates a slow reaction, and high values of p (e.g. bubble columns) should be chosen. For instantaneous reactions Ha > 100, enhancement factor E = 10-50) a low p should be selected with a high degree of gas-phase turbulence. The sulphonation of aromatics with gaseous SO3 is an instantaneous reaction and is controlled by gas-phase mass transfer. In commercial thin-film sulphonators, the liquid reactant flows down as a thin film (low p) in contact with a highly turbulent gas stream (high ka). A thin-film reactor was chosen instead of a liquid droplet system due to the desire to remove heat generated in the liquid phase as a result of the exothermic reaction. Similar considerations are valid for liquid-liquid systems. Sometimes, practical considerations prevail over the decisions dictated from a transport-reaction analysis. Corrosive liquids should always be in the dispersed phase to reduce contact with the reactor walls. Hazardous liquids are usually dispensed to reduce their hold-up, i.e. their inventory inside the reactor. [Pg.388]

Figure 2.27. Mixing, mass transfer and oxygen consumption in a bubble column bioreactor (Oosterhuis, 1984). Tj - reaction time constant, Xmt - ass transfer time constant, tmix -mixing time constant. ro2 - oxygen consumption rate, Vs - superficial gas velocity. Figure 2.27. Mixing, mass transfer and oxygen consumption in a bubble column bioreactor (Oosterhuis, 1984). Tj - reaction time constant, Xmt - ass transfer time constant, tmix -mixing time constant. ro2 - oxygen consumption rate, Vs - superficial gas velocity.
The gas-liquid flow characteristics of stirred vessels depend both on the level of agitation and the rate of gas flow and can vary from the case of bubble column type operation to that of a full circulating tank, as shown in Fig. 5.123. The mixing characteristics and gas distribution obtained, obviously exert a considerable influence on the rate of mass transfer obtained (Harnby et al., 1985). [Pg.457]

In the case of the full bubble column, the bottom gas phase mixed region is coincident with the impeller, and no significant gas mixing occurs below the impeller, in the lower region of the tank, as shown in Fig. 5.125. The dashed arrows in Fig. 5.125 and Fig. 5.126 represent mass transfer interchange between the gas space and liquid volumes of the tank. The liquid circulation, which is not shown, is identical to Fig. 5.124. [Pg.458]

Figure 5.125. Gas phase mixing pattern and mass transfer for full bubble column. Figure 5.125. Gas phase mixing pattern and mass transfer for full bubble column.
GAS-LIQUID MIXING AND MASS TRANSFER IN BUBBLE COLUMN-TYPE MIXING TANK OPERATION EXAMPLE FOR OXYGEN CONSTANT VL1=300, VL2=100,VL3=600 L... [Pg.462]

Romanainen, J.J and Salmi T (1992) The Effect of Reaction Kinetics, Mass Transfer and Flow Pattern on Noncatalytic and Homogeneously Catalyzed Gas-Liquid Reactions in Bubble Columns, Chem Eng Sci, 47 2493. [Pg.141]


See other pages where Mass bubble column is mentioned: [Pg.335]    [Pg.280]    [Pg.1424]    [Pg.1424]    [Pg.1424]    [Pg.1426]    [Pg.2115]    [Pg.2143]    [Pg.69]    [Pg.149]    [Pg.110]    [Pg.112]    [Pg.113]    [Pg.113]    [Pg.134]    [Pg.37]    [Pg.86]    [Pg.641]    [Pg.265]    [Pg.268]    [Pg.292]    [Pg.93]    [Pg.462]    [Pg.126]    [Pg.62]    [Pg.11]   
See also in sourсe #XX -- [ Pg.78 , Pg.80 , Pg.88 ]




SEARCH



Bubble column mass-transfer coefficients

Bubble column, mass transfer models

Bubble columns

Bubble columns virtual mass coefficient

Mass columns

Mass transfer bubble columns

© 2024 chempedia.info