The test load applied is a maximum of 1040 kg at a speed of 1000 rpm applied through a belt from a 1.5 kW three-phase electric motor. Lubrication is supplied through the top of the test head (not shown) and output at either end of the test head an oil bath level is established coincident with the centre of the lowest ball. With an oil sump of 11 litres and a flow... [Pg.342]

The air velocity through a heater battery should be to the manufacturer s rated output within its range of safe temperatures. In large units the electrical load is balanced across the three phases of the electrical supply. [Pg.713]

In 2001, the authors of this chapter developed a 400-W, dc-to-ac inverter using SiC GTOs and p-/-n diodes for operation at case temperatures up to 150°C for driving three-phase, inductive loads up to 5 SOW. The inverter circuit was constructed to perform the first characterization of these SiC devices under significant electrical and thermal stresses, investigate the parametric operating space of the SiC devices, and uncover circuit-related failure modes. [Pg.82]

The hydrogen oxidation within a fuel cell occurs partly at the anode and the cathode. Different models were supposed for the detailed reaction mechanisms of the hydrogen at Ni-YSZ (yttria stabilised zirconia) cermet anodes. The major differences of the models were found with regard to the location where the chemical and electrochemical reactions occur at the TPB (three-phase boundary of the gaseous phase, the electrode and the electrolyte). However, it is assumed that the hydrogen is adsorbed at the anode, ionised and the electrons are used within an external electrical circuit to convert the electrical potential between the anode and the cathode into work. Oxygen is adsorbed at the cathode and ionised by the electrons of the load. The electrolyte leads the oxide ion from the cathode to the anode. The hydrogen ions (protons) and the oxide ion form a molecule of water. The anodic reaction is... [Pg.18]

In addition to the above, NEMA designates a special class of Premium Efficiency Electric Motors (2003) for three-phase induction motors applied to municipal or industrial applications for operation on voltages of 600 V or less, rated 500 HP or less, operating more than 2000 hr/yr at more than 75% of full load. For details, please refer to NEMA MG 1-1998 Table 12-12. For each HP rating, that table defines nominal and minimum efficiencies for 2-, 4-, and 6-pole open motors. [Pg.2418]

AC electric drives require more sophisticated converters when they are supplied with DC sources, because electric machines requires periodic voltage and current waves with a variable frequency depending on the load requirements. In Fig. 5.8, the scheme of an example of three-phase induction motor driven by a pulse-width-modulated inverter is reported. In this scheme a three-phase bridge connection with six power modules is shown to form the so-called inverter. Each power module can be composed by a number of power switches connected in parallel to carry higher currents. Across each power switch (IGBT) a parallel diode is connected to provide a return path for the phase current when the power module is switched off. [Pg.139]

Stable electrical characteristics for the load (1) output voltage and frequency regulation, (2) ideal sine wave output, and (3) true 120° phase shift for three-phase models. [Pg.1122]

Electric motors. The PF of an induction motor varies with the load, as shown in Fig. 10.207. Unloaded or lightly loaded motors exhibit a low PF. Figure 10.208 illustrates the variation of PF and reactive power for varying loads on a three-phase induction motor. Synchronous motors provide good PF when their excitation is adjusted properly. Synchronous motors also can be overexcited to exhibit a leading power factor and, therefore, may be used to improve the power factor of a facility. [Pg.1181]

Today, energy-efficient three-phase induction motors, both open and TEFC, are available in ratings from 1 to 500 hp (0.7 kW to 373 kW). In many locations the cost of electric power is high and energy-efficient motors can be justified on loads operating a high percentage of the time. [Pg.632]

A three phase panel for an office building is described above. Using the National Electric Code defined demand factors, the total kVA load on this panel is most... [Pg.23]

The various stacks tested with the steel and glass-ceramic type are listed in Table 7.4. It was found that severe degradation occurred for stack B and C at 800°C with an electrical load of 0.3 A/cm after 1000 hours of operation. Stack A revealed severe performance degradation after 100-200 h of operation at 800°C with an electrical load of 0.3 A/cm. Strong internal oxidation could be observed at the three phase boundary of steel, glass, and fuel gas. Rapid internal chromia formation... [Pg.290]

Stationary phase loaded with 10% SP-2100 the column was electrically heated with a Ni-Cr wire). Final detection was by ICP-MS. Extraction recoveries were calculated by spiking the material (previously wetted with methanol and mixed with spiking solution) at three levels the recoveries ranged from 97% (TBT) and 98% (MBT) to 112% (DBT). Calibration was by standard additions, using MBTCI3, DBTCI2 and TBTCl in methanol. [Pg.78]


See other pages where Loads three-phase electrical is mentioned: [Pg.494]    [Pg.441]    [Pg.605]    [Pg.80]    [Pg.396]    [Pg.20]    [Pg.40]    [Pg.2501]    [Pg.191]    [Pg.345]    [Pg.1945]    [Pg.112]    [Pg.164]    [Pg.235]    [Pg.74]    [Pg.1095]    [Pg.904]    [Pg.18]    [Pg.1169]    [Pg.2]    [Pg.182]    [Pg.187]    [Pg.115]    [Pg.121]    [Pg.32]    [Pg.324]    [Pg.16]    [Pg.177]    [Pg.151]    [Pg.226]    [Pg.15]    [Pg.192]    [Pg.236]    [Pg.217]    [Pg.191]    [Pg.14]    [Pg.291]   
See also in sourсe #XX -- [ Pg.494 ]




SEARCH



Electric load

Electric loading

Three-phase

© 2024 chempedia.info