Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Limiting plate

For plastic-bonded materials, no clear-cut expression for the coercivity is known. It may be expected that it is rather similar, but with a smaller influence of B. For loosely packed powders, the B influence has become zero and should be multiphed by 0.48 to account for the isotropy (71). In all cases high coercivity is obtained by using small grains with limited plate-like shape, ie, the value of Nis not too high. [Pg.193]

Flow is not constant Flow cannot be controlled easily Limited plate numbers Not always predictable or in agreement with theory Temperature gradients can exist Quantitation not as accurate as for column LC... [Pg.131]

Thus the effect of temperature on plate height involves a complex assessment of the interaction of many factors. At any single temperature, flow conditions cannot be chosen that give minimum plate height for all possible solutes. Within limits, plate height should.usually decrease as temperature is increased. [Pg.480]

The liver forms more lymph than any other organ of the body (0.4-0.6 mg/kg BW/min). Lymph capillaries take up lymph from Disse s space (J. Disse, 1890) and thereafter from Mall s space (F.P. Mall, 1906), which lies between the limiting plate and the portal connective tissue. Disse s space is also considered to be the main source of lymph. In addition, lymph capillaries commence in the adventitia of sublobular veins and run close to the hepatic veins as far as the paracaval lymph nodes. Lymph vessels possess valves which permit the lymph to flow only in one direction. Lymphatic vessels are present in... [Pg.19]

Fig. 2.11 Diagram of the traditional ( classic ) hepatic lobule according to the lobular structure (F. Kiernan, 1833) (s. fig. 1.18) and as stereogram (H. Elias, 1949) the liver cell columns run radially from the limiting plate to the central vein (10) (s. fig. 2.16)... Fig. 2.11 Diagram of the traditional ( classic ) hepatic lobule according to the lobular structure (F. Kiernan, 1833) (s. fig. 1.18) and as stereogram (H. Elias, 1949) the liver cell columns run radially from the limiting plate to the central vein (10) (s. fig. 2.16)...
Periportal inflammation Periportal hepatitis is characterized by penetration of the limiting plate. The border between the portal field and the lobule can appear irregular sometimes it assumes the shape of a maple leaf In this periportal zone (i.e. zone 1), piecemeal necroses may develop. They are, however, not true necroses , but apoptoses. Today, periportal inflammation with piecemeal necrosis is termed interface hepatitis. This condition is not always accompanied by piecemeal necrosis the inflammatory infiltrate can also enter the lobule without causing liver cell necroses. The composition of the inflammatory infiltrates is similar to that in the portal fields. Periportal infiammation contributes to the grading of chronic hepatitis, (l)... [Pg.693]

Centrocytic lymphomas These have their origin in lymphatic germ centre cells. Liver involvement occurs in about 50% of patients. The portal infiltrates consist of small cells with bright, irregularly shaped, indented nuclei. The portal fields are globularly distended as a result of the infiltration the limiting plates remain intact, however, and the portal bile ducts are also undamaged. [Pg.818]

The ASME BPV Code Sec. VIII D.l Part UW describes the requirements for pressure vessels fabricated by welding. Limiting plate thicknesses are specified for each type of weld with the exception of double-welded butt joints. Requirements for radiographic examination of welds are also specified. Section UW-13 of the code specifies the types of welds that can be used to attach heads and tube sheets to shells. Section UW-16 gives rules for attachment of nozzles to vessels. [Pg.983]

The performance of the present approach becomes more obvious in Figure 2a, showing the concentration dependence of Oq. It yields only a weak salinity dependence of the plate spacing and is the only model which is consistent with the observations. The predicted concentration dependence cannot be validated by the scattered data, yet is supported by some limited plate spacing observations in brackish water... [Pg.377]

Limited plate load tests have been carried out within the base of an excavated caisson (Amp 1996 to 2001). The end bearing mobilized was relatively high (fi = 501V). The modulus E was found to be 70,000 kPa. [Pg.135]

The experimental sequence used for these analyses is as follows ions are formed by laser-induced ionization in the source cell (residual pressure 10 Pa). During the ionization event, the conductance limit plate between the two cells (source and analyze) is kept at the trap potential (typically +0.75 V) to confine positive ions to the source side. A variable delay period follows, during which ion/molecule reactions can occur. A frequency excitation chirp allows the ion excitation the resulting image current is finally detected, amplified, digitized, apodized (Blackman-Harris, three terms), and Fourier-transformed to produce a mass spectrum. [Pg.1136]

The principle of the preparation of nonadhering or loose layers consists in an even spreading of the dry adsorbent over a suitable plate. The size of such plates is in no way limited plates 20 —40 cm long are often used, their breadth depending on various factors. They can be made from simple window glass. Sometimes photographic plates freed from emulsion are recommended. [Pg.68]

Load-limit plate OSHA requires that the manufacturer s load-limit plate be permanently mounted on the lift truck. Some states, such as California, require that the truck s capacity be stenciled or identified on the sides of the truck for easier visibility and greater safety. [Pg.189]


See other pages where Limiting plate is mentioned: [Pg.328]    [Pg.279]    [Pg.311]    [Pg.18]    [Pg.21]    [Pg.24]    [Pg.693]    [Pg.694]    [Pg.695]    [Pg.817]    [Pg.818]    [Pg.818]    [Pg.1778]    [Pg.567]    [Pg.60]    [Pg.174]    [Pg.354]    [Pg.404]    [Pg.136]    [Pg.184]    [Pg.247]    [Pg.57]    [Pg.54]    [Pg.186]    [Pg.71]    [Pg.807]   
See also in sourсe #XX -- [ Pg.20 , Pg.22 , Pg.23 ]




SEARCH



© 2024 chempedia.info