Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Level discrepancies

While simulations reach into larger time spans, the inaccuracies of force fields become more apparent on the one hand properties based on free energies, which were never used for parametrization, are computed more accurately and discrepancies show up on the other hand longer simulations, particularly of proteins, show more subtle discrepancies that only appear after nanoseconds. Thus force fields are under constant revision as far as their parameters are concerned, and this process will continue. Unfortunately the form of the potentials is hardly considered and the refinement leads to an increasing number of distinct atom types with a proliferating number of parameters and a severe detoriation of transferability. The increased use of quantum mechanics to derive potentials will not really improve this situation ab initio quantum mechanics is not reliable enough on the level of kT, and on-the-fly use of quantum methods to derive forces, as in the Car-Parrinello method, is not likely to be applicable to very large systems in the foreseeable future. [Pg.8]

The HF level as usual overestimates the polarity, in this case leading to an incorrect direction of the dipole moment. The MP perturbation series oscillates, and it is clear that the MP4 result is far from converged. The CCSD(T) method apparently recovers the most important part of the electron correlation, as compared to the full CCSDT result. However, even with the aug-cc-pV5Z basis sets, there is still a discrepancy of 0.01 D relative to the experimental value. [Pg.287]

Test results provides the hypothesis that syntactic foam is rate insensitive and that the static uniaxial strain stress-strain curve actually represents the general constitutive relation. Disagreement between the experimental data and the predicted behavior is greatest at low stresses (1 kbar) where experimental stresses are about double those predicted analytically. The discrepancy decreases at the higher stress levels and virtually disappears at and beyond 7 kbar. This range... [Pg.501]

The instrument has been evaluated by Luster, Whitman, and Fauth (Ref 20). They selected atomized Al, AP and NGu as materials for study that would be representative of proplnt ingredients. They found that only 2000 particles could be counted in 2 hours, a time arbitrarily chosen as feasible for control work. This number is not considered sufficient, as 18,000 particles are required for a 95% confidence level. Statistical analysis of results obtained for AP was impossible because of discrepancies In the data resulting from crystal growth and particle agglomeration. The sample of NGu could not be handled by the instrument because it consisted of a mixt of needles and chunky particles. They concluded that for dimensionally stable materials such as Al or carborundum, excellent agreement was found with other methods such as the Micromerograph or visual microscopic count. But because of the properties peculiar to AP and NGu, the Flying Spot Particle Resolver was not believed suitable for process control of these materials... [Pg.531]

Also, a specific analysis for the intermediate itself may be developed. It may be detectable at levels below those discernible as discrepancies in the mass balance. If the concentration of. the intermediate is very low, Eqs. (1-5) and (1-6) hold. If not, then reactant consumption and product buildup occur at different rates. Such complications will be considered in Chapters 3 and 4. Most complexities in kinetics involve reactive intermediates. Relatively few reactions of significance occur in a single step, so issues concerning intermediates will recur throughout this book. [Pg.4]

The raw materials used are common and available from a variety of industrial sources and are always used as-received without further purification. All raw materials must be urethane grade, meaning mainly that the water content is less than about 0.05% by weight. If in doubt, water level should be measured.413,42 Bayer products are used where possible, but a detailed description of each compound is given so that substitutes from other manufacturers may be used. However, it cannot be overemphasized that extreme care must be taken when choosing substitutes because even small differences in these complex materials can cause marked discrepancies in results. Sources for common materials, such as 1,4-butanediol, are not specified as these are readily available... [Pg.246]

Theoretical level populations. Sinee there are population variations on time seale shorter than some level lifetimes, a complete description of the excitation has been modeled solving optical Bloch equations Beacon model, Bellenger, 2002) at CEA. The model has been compared with a laboratory experiment set up at CEA/Saclay (Eig. 21). The reasonable discrepancy when both beams at 589 and 569 nm are phase modulated is very likely to spectral jitter, which is not modeled velocity classes of Na atoms excited at the intermediate level cannot be excited to the uppermost level because the spectral profile of the 569 nm beam does not match the peaks of that of the 589 nm beam. [Pg.266]

The coefficient of the 8-function reflects the pile-up of the two-level systems that would have had a value of e < S were it not for quantum effects. These fast two-level systems will contribute to the short-time value of the heat capacity in glasses. The precise distribution in Eq. (69) was only derived within perturbation theory and so is expected to provide only a crude description of the interplay of clasical and quantum effects in forming low-barrier TLS. Quantitative discrepancies from the simple perturbative distribution may be expected owing to the finite size of a tunneling mosaic cell, as mentioned earlier. [Pg.174]

Experimental exposure studies have attempted to associate various neurological effects in humans with specific trichloroethylene exposure levels. Voluntary exposures of 1 hours resulted in complaints of drowsiness at 27 ppm and headache at 81 ppm (Nomiyama and Nomiyama 1977). These are very low exposure levels, but the results are questionable because of the use of only three test subjects per dose, lack of statistical analysis, sporadic occurrence of the effects, lack of clear dose-response relationships, and discrepancies between the text and summary table in the report. Therefore, this study is not presented in Table 2-1. No effects on visual perception, two-point discrimination, blood pressure, pulse rate, or respiration rate were observed at any vapor concentration in this study. Other neurobehavioral tests were not performed, and the subjects were not evaluated following exposure. [Pg.48]

Subsequent studies have confirmed that the reason for this discrepancy is that the rat is able to rapidly metabolise P-carotene to retinol in the intestine, through the action of intestinal dioxygenase. In contrast humans absorb P-carotene systemically such that plasma levels of P-carotene increase to levels not found in the rodent. A more appropriate animal model is the ferret, which shows a similar metabolism to humans. High levels of plasma P-carotene in the ferret induce the cellular transcription factors c-fos and c-jun, and squamous metaplasia is seen in the lung with or without exposure to cigarette smoke (SCF, 2000). Even after the investment of all these resources it has not been possible for the EU Scientific Committee on Food to set an ADI. [Pg.230]

Quality control is intended to monitor and evaluate the performances of both food and human processes that contribute to food quality. The basic principle of this function is the control circle that involves (1) the taking of a process sample by the analysis or measuring unit, (2) determining whether process results meet set tolerances or limits, (3) judging the character and level of any discrepancy, and (4) application of corrective action to adjust the system to an acceptable level (Figure 7.1.1). A distinction is made between measuring and analysis, whereby the first involves direct measurements (e.g., pH, temperature) and the second involves taking samples, sample preparation, and actual analysis. ... [Pg.555]

Harmonic IR spectra of C3H2 calculated at the RHF/6-311++G(d,p), MP2/6-31 1++G(d,p) and MP4/6-31 1++G(d,p) levels are reported in Table 3. The results are nicely converging as electronic correlation is progressively included in the wave function. Excellent agreement between theory and experiment is thus obtained at the MP4 level, which allows for a correct treatment of simultaneous correlation effects in coupled vibrations. The only discrepancies which could show up, would proceed from anharmonicity, as illustrated by the CH stretching vibrations which are found shifted to higher frequencies than anticipated. [Pg.404]

The program must require the vendors to measure a number of reference samples and/or duplicates submitted in a planned sequence. It should require prompt measurement and reporting of these data and should maintain the results in a control chart format. Prompt feedback and follow-up of any apparent data discrepancies and reconciliation of the results with control charts maintained by the vendors are required to minimize the length of uncertain performance. The quality assurance plan should include random sampling of the vendors data for their validity and conformance with quality assurance requirements. If quality assurance is properly practiced at all levels, an inspection of 5 percent of the total data output should be adequate. [Pg.106]


See other pages where Level discrepancies is mentioned: [Pg.59]    [Pg.108]    [Pg.19]    [Pg.109]    [Pg.500]    [Pg.91]    [Pg.59]    [Pg.108]    [Pg.19]    [Pg.109]    [Pg.500]    [Pg.91]    [Pg.1045]    [Pg.513]    [Pg.600]    [Pg.38]    [Pg.98]    [Pg.119]    [Pg.494]    [Pg.47]    [Pg.138]    [Pg.170]    [Pg.419]    [Pg.26]    [Pg.175]    [Pg.177]    [Pg.178]    [Pg.202]    [Pg.39]    [Pg.18]    [Pg.260]    [Pg.280]    [Pg.83]    [Pg.120]    [Pg.559]    [Pg.559]    [Pg.169]    [Pg.190]    [Pg.385]    [Pg.126]   
See also in sourсe #XX -- [ Pg.109 ]




SEARCH



Discrepancies

© 2024 chempedia.info