Leakage rates

FIG. 27-59 Ceramic recuperator. In this design the seals are maintained at relatively low temperatures, leading to leakage rates of only a few percent. (From Goldstick Waste Heat Recovery, Faiimont Press, Atlanta, 1986.)... [Pg.2408]

Toxicity. This factor is becoming an increasingly important consideration in the design of mechanical seals. Since the rubbing seal faces require liquid penetration to cool and lubricate them, it is reasonable to expect that there will be some vapor passing across the faces. This is in fact the case. A normal seal can be expected to leak from a few ppm to 10 cc/min. It is also generally accepted that the seal leakage rate will increase with speed. [Pg.508]

A refinery operation produces about 500,000 barrels of crude per year. There are approximately 1500 gate valves used in the operation. Develop an estimate of the potential hydrocarbon emissions resulting from valve leakage. What is this worth in terms of lost revenues to the facility You can find some information on typical valve leakage rates from searching on w w w. google. com. [Pg.147]

In general, the air leakage rate through a building envelope is dependent... [Pg.579]

ASTM E779-87. 1987 Standard Method for Determining Air Leakage Rate by Fan Pressurization.. American Society for Testing and Materials, Philadelphia. [Pg.599]

TABLE 9.10 Airtightness Classes as Defined in the EUROVENT Guidelines HI Air Leakage Rate in Sheet Metal Air Distribution Systems... [Pg.789]

If the air leakage rate does not comply with the class requirement, the test shall be extended to include an additional equal percentage of the total surface area. [Pg.790]

The absolute, barometric pressure is not normally required in ventilation measurements. The air density determination is based on barometric pressure, but other applications are sufficiently rare. On the other hand, the measurement of pressure difference is a frequent requirement, as so many other quantities are based on pressure difference. In mass flow or volume flow measurement using orifice, nozzle, and venturi, the measured quantity is the pressure difference. Also, velocity measurement with the Pitot-static tube is basically a pressure difference measurement. Other applications for pressure difference measurement are the determination of the performance of fans and air and gas supply and e. -haust devices, the measurement of ductwork tightness or building envelope leakage rate, as well as different types of ventilation control applications. [Pg.1146]

Air leakage rate The leakage of air through an enclosure such as a building or ductwork, expressed as air loss in L/s per m run, or as a percentage loss of the total volume. [Pg.1410]

Fan, gas-tight A fan with a casing that will provide a set air leakage rate at a given operating pressure. [Pg.1438]

Few vacuum systems are completely airtight, although some may have extremely low leakage rates. For the ideal system the only load for the ejector is the non-condens-ables of the process (absorbed gases, air, etc.) plus the saturated vapor pressure equivalent of the process fluid. Practice has proven that allowance must be made for air leakage. Considering the air and non-condensables. For base ejector capacity determine inert gases only by ... [Pg.366]

The air leakage rates indicated are guidelines only. In actual field practice, the air... [Pg.367]

Calculate the total acceptable air leakage rate, Wj, Ib/hr by adding to the sum of the leak rates... [Pg.369]

There should be no perceptible drop in pressure as shown by the test gauge, although a small leakage rate is defined which allows for testing technique limitations. [Pg.284]

Controlled leakage rates easily can be achieved with the correct size packing. [Pg.949]

Wv = Pounds water vapor per pound air w = Constant flow rate, lbs/min wa = Acceptable air leakage rate assigned to a system component, lbs/hr... [Pg.397]

The standards for LDS also specify a minimum bottom slope of 2% and require the installation of a leak detection sump of appropriate size to allow the daily monitoring of liquid levels or inflow rates in the LDS. Specifically, the sump should be designed to detect a top liner leakage rate in the range of action leakage rate (ALR) specified in the leak detection rule. [Pg.1098]


See other pages where Leakage rates is mentioned: [Pg.195]    [Pg.130]    [Pg.131]    [Pg.300]    [Pg.2407]    [Pg.182]    [Pg.654]    [Pg.227]    [Pg.320]    [Pg.369]    [Pg.397]    [Pg.398]    [Pg.477]    [Pg.284]    [Pg.510]    [Pg.512]    [Pg.597]    [Pg.31]    [Pg.369]    [Pg.398]    [Pg.536]    [Pg.634]    [Pg.634]    [Pg.693]    [Pg.1096]    [Pg.1097]    [Pg.1150]    [Pg.288]    [Pg.38]   
See also in sourсe #XX -- [ Pg.83 ]

See also in sourсe #XX -- [ Pg.305 ]




SEARCH



Acceptable Leakage Rate of Chemical Plants

Action leakage rate

Air-leakage rates

Detection Limit for Leakage Rates at Different Connection Positions of a Multistage Pumping System

Fittings leakage rate

Isolator leakage-rate measurement

Leakage

Leakage flow-rate

Leakage rate method

Reference leakage rates

Test chambers leakage rate