Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Lead Sensing

These observations, along with similar results obtained with a variety of complexing ligands, presented convincing evidence that a lead-sensing optrode could be made. The 3 mole % Pb(DVMB)2Br2 complex (2 mole % DVB) was bound by in situ copolymerisation on a 400 pm optical fibre surface. The fibre was then used in the set-up schematically presented in Fig. 19.10. The luminescence... [Pg.458]

Haeckel, S. H., Adaptive Enterprise Creating and Leading Sense-and-Respond Orgemizations, Harvard Business School Press, Boston, 1999. [Pg.353]

As discussed earlier, some biventricular ICDs utilize both right and left ventricular lead sensing for tachyarrhythmia detection. The mechanism facilitating the double counting here, as opposed to earlier cases, was... [Pg.231]

This section attempts a brief review of several areas of research on the significance of phases, mainly for quantum phenomena in molecular systems. Evidently, due to limitation of space, one cannot do justice to the breadth of the subject and numerous important works will go unmentioned. It is hoped that the several cited papers (some of which have been chosen from quite recent publications) will lead the reader to other, related and earlier, publications. It is essential to state at the outset that the overall phase of the wave function is arbitrary and only the relative phases of its components are observable in any meaningful sense. Throughout, we concentrate on the relative phases of the components. (In a coordinate representation of the state function, the phases of the components are none other than the coordinate-dependent parts of the phase, so it is also true that this part is susceptible to measurement. Similar statements can be made in momentum, energy, etc., representations.)... [Pg.101]

J Chem. Phys., 52, 431 (1970)] is a relatively inexpensive one and can be used for calculations on quite large molecules. It is minimal in the sense of having the smallest number of functions per atom required to describe the occupied atomic orbitals of that atom. This is not exactly true, since one usually considers Is, 2s, and 2p, i.e., five functions, to construct a minimal basis set for Li and Be, for example, even though the 2p orbital is not occupied in these atoms. The 2sp (2s and 2p), 3sp, 4sp, 3d,. .., etc. orbitals are always lumped together as a shell , however. The minimal basis set thus consists of 1 function for H and He, 5 functions for Li to Ne, 9 functions for Na to Ar, 13 functions for Kand Ca, 18 functions for Sc to Kr,. .., etc. Because the minimal basis set is so small, it generally can not lead to quantitatively accurate results. It does, however, contain the essentials of chemical bonding and many useful qualitative results can be obtained. [Pg.255]

The sample cells for molecular fluorescence are similar to those for optical molecular absorption. Remote sensing with fiber-optic probes (see Figure 10.30) also can be adapted for use with either a fluorometer or spectrofluorometer. An analyte that is fluorescent can be monitored directly. For analytes that are not fluorescent, a suitable fluorescent probe molecule can be incorporated into the tip of the fiber-optic probe. The analyte s reaction with the probe molecule leads to an increase or decrease in fluorescence. [Pg.428]

The hydrogen atom and one-electron ions are the simplest systems in the sense that, having only one electron, there are no inter-electron repulsions. However, this unique property leads to degeneracies, or near-degeneracies, which are absent in all other atoms and ions. The result is that the spectrum of the hydrogen atom, although very simple in its coarse structure (Figure 1.1) is more unusual in its fine structure than those of polyelectronic atoms. For this reason we shall defer a discussion of its spectrum to the next section. [Pg.213]

Many human diseases are caused when certain proteins are either over- or underexpressed. Eor example, breast cancer can be induced by overexpressing certain cellular oncogenes within mammary tissue. To study the disease, researchers produce a line of transgenic mice that synthesize an abnormal amount of the same protein. This leads to symptoms of the disease in mice that are similar to what is found in humans. A protein can be overexpressed by inserting a DNA constmct with a strong promotor. Conversely, underexpression of a protein can be achieved by inserting a DNA constmct that makes antisense RNA. This latter blocks protein synthesis because the antisense RNA binds and inactivates the sense mRNA that codes for the protein. Once a line of mice is developed, treatments are studied in mice before these therapies are appHed to humans. [Pg.242]

Lead Telluride. Lead teUuride [1314-91 -6] PbTe, forms white cubic crystals, mol wt 334.79, sp gr 8.16, and has a hardness of 3 on the Mohs scale. It is very slightly soluble in water, melts at 917°C, and is prepared by melting lead and tellurium together. Lead teUuride has semiconductive and photoconductive properties. It is used in pyrometry, in heat-sensing instmments such as bolometers and infrared spectroscopes (see Infrared technology AND RAMAN SPECTROSCOPY), and in thermoelectric elements to convert heat directly to electricity (33,34,83). Lead teUuride is also used in catalysts for oxygen reduction in fuel ceUs (qv) (84), as cathodes in primary batteries with lithium anodes (85), in electrical contacts for vacuum switches (86), in lead-ion selective electrodes (87), in tunable lasers (qv) (88), and in thermistors (89). [Pg.69]

Laser sources that emit in the mid-ir region of the spectmm (2—5 -lm) are useful for detection of trace gases because many molecules have strong absorption bands in that region. Other appHcations include remote sensing and laser radar. Semiconductor lead—salt (IV—VI) lasers that operate CW at a temperature of 200 K and emission wavelength of 4 p.m are commercially available however, they have relatively low output powers (<1 mW) (120). [Pg.379]

Various protective instruments are used to provide a shutdown signal (to a fast-acting trip valve at the expander inlet) that senses various things, such as overspeed, lubricant pressure, bearing temperature, lubricant temperature, shaft runout, icing, lubricant level, thrustbearing load, and process variables such as sensitive temperatures, levels, pressures, etc. However, too many safety shutdown devices may lead to excessive nuisance shutdowns. [Pg.2524]


See other pages where Lead Sensing is mentioned: [Pg.13]    [Pg.13]    [Pg.18]    [Pg.580]    [Pg.13]    [Pg.13]    [Pg.18]    [Pg.580]    [Pg.1017]    [Pg.276]    [Pg.891]    [Pg.2116]    [Pg.2465]    [Pg.390]    [Pg.600]    [Pg.285]    [Pg.195]    [Pg.727]    [Pg.1068]    [Pg.34]    [Pg.299]    [Pg.80]    [Pg.246]    [Pg.274]    [Pg.110]    [Pg.198]    [Pg.343]    [Pg.472]    [Pg.36]    [Pg.394]    [Pg.481]    [Pg.365]    [Pg.312]    [Pg.381]    [Pg.400]    [Pg.70]    [Pg.263]    [Pg.243]    [Pg.349]    [Pg.349]    [Pg.213]    [Pg.258]    [Pg.36]   
See also in sourсe #XX -- [ Pg.90 ]




SEARCH



© 2024 chempedia.info