Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Interferences Subject

The children s version of the Yale-Brown Obsessive Compulsive Scale (CY-BOCS) is a 10-item anchored ordinal scale (0-4) that rates the clinical severity of the disorder by scoring the time occupied, degree of life interference, subjective distress, internal resistance, and... [Pg.513]

For a method to be useful it must provide reliable results. Unfortunately, methods are subject to a variety of chemical and physical interferences that contribute uncertainty to the analysis. When a method is relatively free from chemical interferences, it can be applied to the determination of analytes in a wide variety of sample matrices. Such methods are considered robust. [Pg.42]

The regression models considered earlier apply only to functions containing a single independent variable. Analytical methods, however, are frequently subject to determinate sources of error due to interferents that contribute to the measured signal. In the presence of a single interferent, equations 5.1 and 5.2 become... [Pg.127]

Choice of Atomization and Excitation Source Except for the alkali metals, detection limits when using an ICP are significantly better than those obtained with flame emission (Table 10.14). Plasmas also are subject to fewer spectral and chemical interferences. For these reasons a plasma emission source is usually the better choice. [Pg.437]

When possible, quantitative analyses are best conducted using external standards. Emission intensity, however, is affected significantly by many parameters, including the temperature of the excitation source and the efficiency of atomization. An increase in temperature of 10 K, for example, results in a 4% change in the fraction of Na atoms present in the 3p excited state. The method of internal standards can be used when variations in source parameters are difficult to control. In this case an internal standard is selected that has an emission line close to that of the analyte to compensate for changes in the temperature of the excitation source. In addition, the internal standard should be subject to the same chemical interferences to compensate for changes in atomization efficiency. To accurately compensate for these errors, the analyte and internal standard emission lines must be monitored simultaneously. The method of standard additions also can be used. [Pg.438]

Water drops condensed in the atmosphere have much larger dimensions than gas molecules hence they are subject to the interference phenomena mentioned at the end of the last section. This alters the color of the scattered light. Smoke and dust particles are also larger and may absorb as well. [Pg.677]

Calcium Absorption. Phytates in cereal grains have also been reported to interfere with the absorption of calcium. However, a long-term study indicated a retention of calcium in subjects that consume large amounts of bread made with high extraction of flour (19). [Pg.352]

Ferrous Sulfdte Titration. For deterrnination of nitric acid in mixed acid or for nitrates that are free from interferences, ferrous sulfate titration, the nitrometer method, and Devarda s method give excellent results. The deterrnination of nitric acid and nitrates in mixed acid is based on the oxidation of ferrous sulfate [7720-78-7] by nitric acid and may be subject to interference by other materials that reduce nitric acid or oxidize ferrous sulfate. Small amounts of sodium chloride, potassium bromide, or potassium iodide may be tolerated without serious interference, as can nitrous acid up to 50% of the total amount of nitric acid present. Strong oxidizing agents, eg, chlorates, iodates, and bromates, interfere by oxidizing the standardized ferrous sulfate. [Pg.47]

Analytical and Test Methods. o-Nitrotoluene can be analyzed for purity and isomer content by infrared spectroscopy with an accuracy of about 1%. -Nitrotoluene content can be estimated by the decomposition of the isomeric toluene diazonium chlorides because the ortho and meta isomers decompose more readily than the para isomer. A colorimetric method for determining the content of the various isomers is based on the color which forms when the mononitrotoluenes are dissolved in sulfuric acid (45). From the absorption of the sulfuric acid solution at 436 and 305 nm, the ortho and para isomer content can be deterrnined, and the meta isomer can be obtained by difference. However, this and other colorimetric methods are subject to possible interferences from other aromatic nitro compounds. A titrimetric method, based on the reduction of the nitro group with titanium(III) sulfate or chloride, can be used to determine mononitrotoluenes (32). Chromatographic methods, eg, gas chromatography or high pressure Hquid chromatography, are well suited for the deterrnination of mononitrotoluenes as well as its individual isomers. Freezing points are used commonly as indicators of purity of the various isomers. [Pg.70]

Ozone in the gas phase can be deterrnined by direct uv spectrometry at 254 nm via its strong absorption. The accuracy of this method depends on the molar absorptivity, which is known to 1% interference by CO, hydrocarbons, NO, or H2O vapor is not significant. The method also can be employed to measure ozone in aqueous solution, but is subject to interference from turbidity as well as dissolved inorganics and organics. To eliminate interferences, ozone sometimes is sparged into the gas phase for measurement. [Pg.503]

The interference proceeding is declared by the patent examiner and occurs in the U.S. PTO. Once an interference is declared, a deterrnination is made as to the exact subject matter constituting the invention of the interference and who filed the first patent appHcation on that invention. The first appHcant becomes the senior party to the interference. The junior party has the burden of proving that it was prior in time as to its date of invention. [Pg.37]

Vitamin D deficiency in animals may be caused by the fact that the vitamin is not available to the hvestock. Modem animal husbandry subjects animals to total confinement with htde or no exposure to sunlight. This mandates that they be given vitamin D-fortified diets. The vitamin is sensitive to oxidation, heat, light, and minerals, and significant losses may occur in the fortified feed unless the product is adequately protected. Mycotoxins in feeds also interfere with utilization of vitamin D in feeds (207—209). [Pg.137]

Specific-Ion Electrodes In addition to the pH glass electrode specific for hydrogen ions, a number of electrodes that are selective for the measurement of other ions have been developed. This selectivity is obtained through the composition of the electrode membrane (glass, polymer, or liquid-liquid) and the composition of the elec trode. Tbese electrodes are subject to interference from other ions, and the response is a function of the total ionic strength of the solution. However, electrodes have been designed to be highly selective for specific ions, and when properly used, these provide valuable process measurements. [Pg.765]

We provide more details on inductive interferences in the box below, to make the subject of electrical interference more informative. We also provide a passing reference to communication systems being adopted worldwide. [Pg.735]

Fig 9-18 Current distribution and voltage cone Af/ at a defect in the pipe coating of a cathodically protected pipeline and the variation in the pipe/ soil potential of a pipeline subjected to interference. [Pg.260]

Fig. 23-4 Equivalent circuit diagram for a pipeline subjected to interference. Fig. 23-4 Equivalent circuit diagram for a pipeline subjected to interference.
To determine the pipeline potentials, the resultant induced field strengths have to be included in the equations in Section 23.3.2. Such calculations can be carried out with computers that allow detailed subdivision of the sections subject to interference. A high degree of accuracy is thus achieved because in the calculation with complex numbers, the phase angle will be exactly allowed for. Such calculations usually lead to lower field strengths than simplified calculations. Computer programs for these calculations are to be found in Ref. 16. [Pg.521]

The theory is concerned with the problem of determining the probability of failure of a part which is subjected to a loading stress, L, and which has a strength, S. It is assumed that both L and S are random variables with known PDFs, represented by f S) and f L) (Disney et al., 1968). The probability of failure, and hence the reliability, can then be estimated as the area of interference between these stress and strength functions (Murty and Naikan, 1997). [Pg.176]

The final reliability formulation for the interference of two 3-parameter Weibull distributions subjected to multiple load applications is given in equation 4.84 ... [Pg.220]

The subtle interaction of air pollutants with these other stressors to plants and vegetation is the subject of ongoing research. For some plant systems, exposure to air pollutants may induce biochemical modifications which interfere with the water balance in plants, thereby reducing their ability to tolerate drought conditions. [Pg.112]

Controlling high frequency noise generation and radiation is the blackest of the black box art in switching power supply and product-system design. It is a subject that warrants a book all to itself and it is the final area that will interfere with the release of your product into the market. This appendix cannot adequately cover the subject, but will overview the major considerations involved with product design. [Pg.241]

Gases for mixing with argon, such as N2 and Xe, have been the subject of study for some time. Some new instrumentation tvill incorporate manifolds for making this process easier. Other plasma developments include microwave-induced plasmas with He to eliminate interferences from argon containing molecular species. [Pg.631]


See other pages where Interferences Subject is mentioned: [Pg.49]    [Pg.49]    [Pg.721]    [Pg.102]    [Pg.345]    [Pg.416]    [Pg.438]    [Pg.543]    [Pg.78]    [Pg.196]    [Pg.84]    [Pg.95]    [Pg.200]    [Pg.380]    [Pg.66]    [Pg.497]    [Pg.134]    [Pg.316]    [Pg.230]    [Pg.127]    [Pg.485]    [Pg.124]    [Pg.731]    [Pg.258]    [Pg.527]    [Pg.293]    [Pg.84]    [Pg.612]    [Pg.225]    [Pg.211]   