Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Interface channel

The method of capturing the customer complaints from all interface channels with the customer... [Pg.454]

Note that this is a very simplified case. A liquid junction, dual-layer insulator, trapped charges in the insulator, surface states at the insulator/semiconductor interface, channel doping profile, and multiple connecting metals have been omitted, for the sake of simplicity. They would be present in all real devices and situations, but would not affect the thought analysis in any significant way. [Pg.157]

The staff concludes that the organizational changes recently implemented by WSRC provide adequate alignment of responsibilities and interface channels to satisfy the restart criterion for core design responsibility. [Pg.225]

These two transducer pairs are activated alternating. For this purpose an ultrasonic instrument is combined with a two channel multiplexer. Figure 8 presents a modified standard instrument USN52 which also implies a modified software. This system performs four measurements per second - alternating the velocity and the thickness are determined. The probe can be scanned over the surface and in every position both, the velocity and the wall thickness are indicated Using the serial interface of the instrument finally a two-dimensional map of velocity or thickness can be generated. [Pg.763]

In order that the data acquisition system can obtain information about the spatial location and orientation of the probe, a four-channel incremental encoder interface board is installed. Three channels are used to define position in three-dimensional space, while the fourth monitors the skew of the probe (skew is defined as rotation about an axis normal to the probe face). Although six measurements are required to completely define the location and orientation, it is assumed that the probe remains in contact with the inspection surface. [Pg.768]

The carriers in tire channel of an enhancement mode device exhibit unusually high mobility, particularly at low temperatures, a subject of considerable interest. The source-drain current is carried by electrons attracted to tire interface. The ionized dopant atoms, which act as fixed charges and limit tire carriers mobility, are left behind, away from tire interface. In a sense, tire source-drain current is carried by tire two-dimensional (2D) electron gas at tire Si-gate oxide interface. [Pg.2892]

A typical transputer architecture. The transputer (sometimes referred to as a computer on a chip) has four input/output links (0, 1, 2, 3) to other transputers, a channel for inputting/requesting data (event link), some built-in random-access memory, an interface to the main operating system (clock, boot, etc.), and an external memory interface. Internal communication is via a bus. [Pg.313]

Effusion separator (or effusion enricher). An interface in which carrier gas is preferentially removed from the gas entering the mass spectrometer by effusive flow (e.g., through a porous tube or through a slit). This flow is usually molecular flow, such that the mean free path is much greater than the largest dimension of a traverse section of the channel. The flow characteristics are determined by collisions of the gas molecules with surfaces flow effects from molecular collisions are insignificant. [Pg.432]

Fig. 25. OxyTech MGC electroly2er a, membrane b, anode assembly c, manifold spacer d, anolyte outlet e, catholyte outlet f, bulkhead g, brine inlet h, NaOH inlet i, insulating channel j, bulkhead insulator k, interface material 1, cathode assembly m, interceU bus n, tie rod o, current distributor p,... Fig. 25. OxyTech MGC electroly2er a, membrane b, anode assembly c, manifold spacer d, anolyte outlet e, catholyte outlet f, bulkhead g, brine inlet h, NaOH inlet i, insulating channel j, bulkhead insulator k, interface material 1, cathode assembly m, interceU bus n, tie rod o, current distributor p,...
An improperly designed interface to the belt can cause soHds compaction, abrasive wear of the belt, and excessive power requited to move the belt. The preferential flow channel shown in Figure 9b withdraws material from one end of the outlet. Depending on the gate opening, this could be at the back... [Pg.557]

The K+ channel is a tetrameric molecule with one ion pore in the interface between the four subunits... [Pg.232]

Relative photoionization cross sections for molecules do not vary gready between each other in this wavelength region, and therefore the peak intensities in the raw data approximately correspond to the relative abundances of the molecular species. Improvement in quantification for both photoionizadon methods is straightforward with calibration. Sampling the majority neutral channel means much less stringent requirements for calibrants than that for direct ion production from surfaces by energetic particles this is especially important for the analysis of surfaces, interfaces, and unknown bulk materials. [Pg.563]

In what documents are the channels of communication and interface with the customer defined ... [Pg.233]

Simulations of water in synthetic and biological membranes are often performed by modeling the pore as an approximately cylindrical tube of infinite length (thus employing periodic boundary conditions in one direction only). Such a system contains one (curved) interface between the aqueous phase and the pore surface. If the entrance region of the channel is important, or if the pore is to be simulated in equilibrium with a bulk-like phase, a scheme like the one in Fig. 2 can be used. In such a system there are two planar interfaces (with a hole representing the channel entrance) in addition to the curved interface of interest. Periodic boundary conditions can be applied again in all three directions of space. [Pg.353]

FIG. 7 Log-log plots of the interface width (w ) versus the Monte Carlo time t, measured at different adsorption probabihties using channels of width L = 30. Data were obtained during the displacement of an A-poisoned phase by the reactive regime. From top to bottom the probabihties are 0.5192, 0.5202, 0.5211, 0.5215, and 0.5238. [Pg.403]

Figure 9.7 Schematic illustration of the flow-gating interface. A channeled Teflon gasket was sandwiched between two stainless steel plates to allow for flow into the electrophoresis capillary, either from the flush buffer reservoir or from the LC microcolumn during an electiokinetic injection. Figure 9.7 Schematic illustration of the flow-gating interface. A channeled Teflon gasket was sandwiched between two stainless steel plates to allow for flow into the electrophoresis capillary, either from the flush buffer reservoir or from the LC microcolumn during an electiokinetic injection.

See other pages where Interface channel is mentioned: [Pg.164]    [Pg.143]    [Pg.1313]    [Pg.415]    [Pg.231]    [Pg.227]    [Pg.1409]    [Pg.346]    [Pg.1378]    [Pg.164]    [Pg.143]    [Pg.1313]    [Pg.415]    [Pg.231]    [Pg.227]    [Pg.1409]    [Pg.346]    [Pg.1378]    [Pg.768]    [Pg.2892]    [Pg.552]    [Pg.371]    [Pg.391]    [Pg.409]    [Pg.418]    [Pg.1147]    [Pg.451]    [Pg.100]    [Pg.38]    [Pg.503]    [Pg.504]    [Pg.139]    [Pg.149]    [Pg.447]    [Pg.456]    [Pg.255]    [Pg.269]    [Pg.349]    [Pg.402]    [Pg.423]    [Pg.56]    [Pg.52]    [Pg.207]   
See also in sourсe #XX -- [ Pg.62 ]