Instrument filtering

One laboratory had surprisingly few problems with its instrument air, which was supplied from a commercial compressor with no special equipment. This laboratory was on the second floor of a building, while the compressor was at ground level. The air was taken upstairs through a pipe much larger than would ordinarily be used for such service. Since the air velocity was therefore very low, the pipe acted like a rectifier column and sent most of the contaminants back to the compressor air tank. As a result, the instrument filter needed very infrequent servicing. [Pg.92]

TTie Aroma software controls the sample change, pumps, valves and connected measuring instruments. The software also receives all measured results from the instruments, filters, stores and prints them. [Pg.205]

But, with increasing complications of instrument design and flexibility of use, the foregoing terms still are not sufficient to fully describe many instruments, Although some instruments display a continuous spectrum of what is being measured, other instruments filter out, for example, certain... [Pg.1531]

There are four basically different instrument designs, based on how incident energy is selected (McClure, 1994). These are grating instruments (monochromators), Fourier transform instruments, filter instruments and Diode Array-based instruments. Figure4 illustrates the basic design of a scanning NIR spectrophotometer. [Pg.303]

As far as maintenance of coalescing elements is concerned, the test is the pressure drop across the filter, from inlet to outlet. Most outlet filters have pressure indicators of one form or another. Typically when a pressure differential of 0.5-0.7 bar is indicated, the element must be changed. Figure 6.41 shows a suitably instrumented filter. [Pg.430]

In addition to the distortions caused by the probes, there were also distortions caused by filtering the signals within the eddy-current test instruments. To achieve the highest possible dynamics with the test instruments, high-pass filters with a high rate of rise, but also a long reverberation time were used. Thus, the recorded C-scan pictures sometimes shows strong echo effects. [Pg.309]

Aside from the smgle mass filter, the most connnon configuration for quadnipole mass spectrometers is the triple-quadnipole instrument. This is the simplest tandem mass spectrometer using quadnipole mass filters. Typically, the... [Pg.1342]

A sehematie diagram of a SIFT apparatus is shown in figure Bl.7.12. The instrument eonsists of five basie regions, the ion soiiree, initial quadnipole mass filter, flow tube, seeond mass filter and finally the deteetor. The heart of the instrument is the flow tube, whieh is a steel tube approximately 1 m long and 10 em in diameter. The pressure in the flow tube is kept of the order of 0.5 Torr, resulting in earrier gas flow rates of... [Pg.1344]

Another instrument used in physical chemistry research that employs quadnipole mass filters is the guided ion beam mass spectrometer [31]. A schematic diagram of an example of this type of instrument is shown in figure B 1.7.13. A... [Pg.1345]

The field of corrected microscopes has just begun with the instruments discussed above. The progress in this field is very rapid and proposals for a sub-Angstrom TEM (SATEM) or even the combination of this instrument with a corrected energy filter to fonn a sub-electronvolt/sub-Angstrom TEM (SESAM) are underway. [Pg.1644]

A simple instrument for measuring absorbance that uses absorption or interference filters to select the wavelength. [Pg.388]

Block diagram for a filter photometer with photo showing a typical hand-held instrument suitable for field work. Colorimeterrw is manufactured by Hach Company/photo courtesy of Hach Company. [Pg.389]

Instrument Designs for Infrared Absorption The simplest instrument for IR absorption spectroscopy is a filter photometer similar to that shown in Figure 10.24 for UV/Vis absorption. These instruments have the advantage of portability and typically are used as dedicated analyzers for gases such as ITCN and CO. [Pg.393]

An instrument for measuring fluorescence that uses filters to select the excitation and emission wavelengths. [Pg.428]

In a sector instrument, which acts as a combined mass/velocity filter, this difference in forward velocity is used to effect a separation of normal and metastable mj" ions (see Chapter 24, Ion Optics of Magnetic/Electric-Sector Mass Spectrometers ). However, as discussed above, the velocity difference is of no consequence to the quadmpole instrument, which acts only as a mass filter, so the normal and metastable mj ions formed in the first field-free region (Figure 33.1) are not differentiated. [Pg.233]

Photomultipliers are used to measure the intensity of the scattered light. The output is compared to that of a second photocell located in the light trap which measures the intensity of the incident beam. In this way the ratio [J q is measured directly with built-in compensation for any variations in the source. When filters are used for measuring depolarization, their effect on the sensitivity of the photomultiplier and its output must also be considered. Instrument calibration can be accomplished using well-characterized polymer solutions, dispersions of colloidal silica, or opalescent glass as standards. [Pg.692]

Validation Guidefor the Palltronic FFE03-P Filter Integrity Pest Instrument TRFFE03-P, PaU Corp., East HiUs, N.Y., 1992. [Pg.145]

Lines are not Follow operating procedures depressurized, Install pressure indication instrumentation and before checking, changing filters. CCPS G-3 CCPS G-22 CCPS G-23 CCPS G-29... [Pg.92]

As noted from general experience, except for specific large inductive loads such as of furnace or rectifiers, the fundamental content of the load current is high compared to the individual harmonic contents. In all such cases, it is not necessary to provide a filter-circuit for each harmonic unless the current is required to be as close to a sinusoidal waveform as possible, to cater to certain critical loads or instruments and devices or protective schemes operating in the system, where a small amount of harmonics may lead to malfunctioning of such loads and devices. Otherwise only the p.f. needs be improved to the desired level. Also to eliminate a parallel resonance with the... [Pg.745]

Filters have a time constant r = R x C which increases the damping of the measuring instrument. The time constant depends on the required attenuation and the interfering frequency, but not on the internal resistance of the measuring instrument. The time constants of the shielding filter are in the same range as those of the electrochemical polarization, so that errors in the off potential are increased. Since the time constants of attenuation filters connected in tandem are added, but the attenuation factors are multiplied, it is better to have several small filters connected in series rather than one large filter. [Pg.102]

At high pressure experiments the reactor should be installed in a pressure cell. All check valves before it, and the filter with the flow controller after it, can be kept in the vented operating room. As a minimum, the bypass valve and the flow controller must be accessible to the operator. This can be done by extended valve stems that reach through the protecting wall. Both the operating room and the pressure cell should be well ventilated and equipped by CO alarm instruments. [Pg.86]

Lube oil units are typieally available in two versions the manu-faeturer s standard or in aeeordanee with API Standard 614. The major eomponents of a unit are the oil tank, auxiliary oil pump, double filter and, seleetively, one or two oil eoolers. All eomponents of the smaller units are mounted on a eommon bedplate, separated from the other eomponents. The oil ean be heated by an eleetrieal or steam-powered heating unit. The neeessary instrumentation is a standard supply item and, if requested, the switehes and motors ean be prewired. The main and auxiliary oil pumps are driven by different types of drivers (e.g., one by an eleetrie motor and the other by either a small steam turbine or by direet eonneetion to the shaft end of a major maehine easing in the turbotrain). [Pg.129]

Figure 15-1 shows the Los Angeles, California, basin stationary air monitoring network, one of the most extensive in the United States (6). At most of these locations, automated instruments collect air quality data continuously. Five pollutant gases are monitored, and particulate matter filter samples are collected periodically. [Pg.218]


See other pages where Instrument filtering is mentioned: [Pg.55]    [Pg.366]    [Pg.1330]    [Pg.376]    [Pg.37]    [Pg.1218]    [Pg.693]    [Pg.25]    [Pg.284]    [Pg.55]    [Pg.366]    [Pg.1330]    [Pg.376]    [Pg.37]    [Pg.1218]    [Pg.693]    [Pg.25]    [Pg.284]    [Pg.1341]    [Pg.1033]    [Pg.388]    [Pg.424]    [Pg.428]    [Pg.583]    [Pg.584]    [Pg.772]    [Pg.772]    [Pg.231]    [Pg.278]    [Pg.690]    [Pg.198]    [Pg.1238]    [Pg.1470]    [Pg.90]    [Pg.96]    [Pg.102]   
See also in sourсe #XX -- [ Pg.33 ]




SEARCH



Acousto-optic tunable filter instruments

Filter instruments

Filter-based instruments

Fluorescence filter instruments

Fluorescent detection, instrument optical filter

Instrumentation of Filter IR and Photoacoustic Detectors

Interference filter instrument

Luminescence instrumentation filters

© 2024 chempedia.info