Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Installation meaning

In some cases though, it is not possible to analyse the SIF because it simply does not exist. The function was never part of the original installation meaning that the SIF has to be either added or, if the SIF cannot he added because of the physical construction of the hoist, best practice cuid other risk reduction strategies employed. [Pg.278]

Finally, it is by means of synergy between the refining processes and the combustion techniques that the emissions of NO due to industrial installations can be minimized. [Pg.269]

Whether on land or offshore, the principle of satellite development is the same. A new field is accessed with wells, and an export link is installed to the existing (host) facility. Development is not always easier on land, as environmental restrictions mean that some onshore fields have to be developed using directional drilling techniques (originally associated with offshore developments). A vertical well can be drilled offshore away from the host facility, and the well completed using a subsea wellhead. [Pg.362]

The role that a host facility plays in an incremental development project can vary tremendously. At one extreme all production and processing support may be provided by the host (such as gas lift and water treatment). On the other hand, the host may just become a means of accessing an export pipeline (if a production and processing facility is installed on the new field). [Pg.363]

An alternative to macroclimate systems is the creation of microclimates. The objects are placed within smaller spaces, such as cases, in which an ideal environment is maintained. One possibiUty is to install equipment to control the climate in individual cases, or groups of cases with similar materials, by mechanical means. [Pg.429]

Pollutants. The problems posed by ak pollutants are very serious. Within a museum, measures can be taken to remove harmful substances as efficiently as possible by means of the installation of appropriate filter systems in the ventilation equipment. Proposed specification values for museum climate-control systems requke filtering systems having an efficiency for particulate removal in the dioctyl phthalate test of 60—80%. Systems must be able to limit both sulfur dioxide and nitrogen dioxide concentrations <10 /ig/m, and ozone to <2 /ig/m. ... [Pg.429]

Power Supplies and Controls. Induction heating furnace loads rarely can be connected directiy to the user s electric power distribution system. If the load is to operate at the supply frequency, a transformer is used to provide the proper load voltage as weU as isolation from the supply system. Adjustment of the load voltage can be achieved by means of a tapped transformer or by use of a solid-state switch. The low power factor of an induction load can be corrected by installing a capacitor bank in the primary or secondary circuit. [Pg.127]

A more advanced mirror approach involving multicells, called the tandem mirror, has been studied as a means to overcome the leakage problem. One way to view the tandem mirror is as a long uniform magnetic solenoid with two single-cell mirrors installed at the ends to electrostatically plug the device. Plasma end losses ate impeded by electrostatic potentials developed by the plasma as the electrons and ions attempt to leave the device at different rates. [Pg.152]

An example in support of the first point is the case of optimum insulation thickness. A tank, optimally insulated when first installed, can fall below optimal if the value of heat is quadmpled. This change can justify twice the old iasulation thickness on a new tank. However, the old tank may have to function with its old iasulation. The reason is that there are large costs associated with preparation to iasulate. This means that the cost of an added increment of iasulation is much greater than assumed ia the optimum iasulation thickness formulas (Fig. 15). [Pg.94]

In addition, other utiUties are installing estabUshed solar cells in a growing number of tests that may lead to a mass market. The studies may indicate the extent to which solar cells can be used to avoid installation costs for new distribution lines between conventional power plants and remote customers buildings. Also, among other objectives, PV cells may provide an economical means of helping to supply demand during peak summer periods in northern climates. [Pg.105]

Orthokinetic flocculation is induced by the motion of the Hquid obtained, for example, by paddle stirring or any other means that produces shear within the suspension. Orthokinetic flocculation leads to exponential growth which is a function of shear rate and particle concentration. Large-scale one-pass clarifiers used in water installations employ orthokinetic flocculators before introducing the suspension into the settling tank (see Water,... [Pg.318]

Small Communities. Small communities and recent subdivision additions to larger communities, which have not yet been coimected to municipal coUection systems, must have a means of waste disposal. Septic tanks are a possibiHty, but require periodic servicing and cleaning. Furthermore, the soil is not always suitable for accepting the effluent. An alternative is the package plant. These units are commercially produced to serve small areas. They furnish primary treatment and some secondary treatment, and require only minimal operating supervision. Capacity can be varied as needs dictate. In general, pubHc health authorities prefer such installations instead of septic tanks. [Pg.282]

Catalysts intended for different appHcations may require their own unique types of reactor and operating conditions, but the key to designing a successful system is to use the same feedstock composition that is expected in the ultimate commercial installation and to impose so far as is possible the same operating conditions as will be used commercially (35). This usually means a reactor design involving a tubular or smaH-bed reactor of one type or another that can simulate either commercial multitubular reactors or commercial-size catalyst beds, including radial flow reactors. [Pg.197]

Evaporator may refer either to the type of constmction utilized or to the entire assemblage of equipment in a single installation. Thus a single multiple-effect evaporator may contain a number of effects of either the same or different evaporator types. An effect is a section of the evaporator heated by steam at one pressure and releasing vapor (water) at a lower pressure to another section. The term steam generally indicates the heat supply, whereas vapor means the material evaporated. Thus vapor from one effect becomes steam at the next effect. The term prime steam identifies the steam suppHed from an outside source to operate the evaporator (see also Steam). An effect may consist of several bodies, all operating at the same steam and vapor pressures. The purpose of more than one body in an effect may be to handle Hquor at different concentrations, or the result of size limitations or of additions to increase the capacity of an existing evaporator. [Pg.472]

Assistance in problem definition and in developing a test program should be sought from persons experienced in the field. If your organization has a consultant in separations of this land, by all means m e use of the expertise available. If not, it may be wise to employ an outside consultant, whose special knowledge and guidance can save time, money, and headaches. It is important to do this early after the separation equipment has been installed, there is httle a consultant can do to remedy the sometimes disastrous effects of a poor selection. Often it is best to work with established equipment manufacturers throughout the selection process, unless the problem is unusually sensitive or confidential. Their experience with problems similar to yours may be most helpful and avoid many false starts. [Pg.1749]


See other pages where Installation meaning is mentioned: [Pg.130]    [Pg.441]    [Pg.876]    [Pg.316]    [Pg.273]    [Pg.102]    [Pg.130]    [Pg.441]    [Pg.876]    [Pg.316]    [Pg.273]    [Pg.102]    [Pg.378]    [Pg.882]    [Pg.911]    [Pg.156]    [Pg.255]    [Pg.381]    [Pg.403]    [Pg.114]    [Pg.166]    [Pg.332]    [Pg.428]    [Pg.144]    [Pg.105]    [Pg.383]    [Pg.236]    [Pg.473]    [Pg.102]    [Pg.1]    [Pg.90]    [Pg.405]    [Pg.297]    [Pg.411]    [Pg.29]    [Pg.224]    [Pg.476]    [Pg.785]    [Pg.1051]    [Pg.1100]    [Pg.1143]    [Pg.1963]   
See also in sourсe #XX -- [ Pg.558 ]




SEARCH



© 2024 chempedia.info