Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Infrared accessories

Am Assoc of Cereal Chemists, St. Paul, MN, 330pp Yang PW, Mantsch HH, Baudais F (1986) A critical evaluation of three types of diffuse reflectance infrared accessories. AppI Spectrosc 40 974-978 Yasuda T, Sakakibara A (1981) Hydrogenolysis of protolignin in compression wood. V. [Pg.370]

Investigation of low wavenumber bands is possible compared with infrared which has a much higher wavenumber cut-off (for infrared this is variable and dependent on the mode and infrared accessory used). [Pg.295]

We wish to describe in this chapter some of the new and innovative infrared accessories commercially available to the experimental chemist. All of the infrared items described herein were obtained from Spectra Tech, Inc. (652 Glenbrook Road, P. 0. Box 2190-G, Stanford, CT 06906, Ph. (800)243-9186). The conditions for which we have demonstrated the use of these devices involving in situ infrared spectroscopy include the following ... [Pg.230]

To press a disc, the following is required infrared-quality KBr, a press (hand-held or hydraulic) capable of delivering from 15 000 to 25 000 psi pressure, a die, and a mortar and pestle (usually made of agate). The KBr should be kept in a clean, dry environment— preferably a desiccator or a drying oven maintained at 105 C. The storage unit should not be used for anything which might contaminate the KBr by sublimation or evaporation. The die is a simple infrared accessory which holds the powder between two platens while pressure is applied. [Pg.248]

Merrill, R. A., and E.G.Bartidc"Analy of Pressure Sensitive Adhesives Tape L Evaluation of Infrared Accessory Advances." Journal cf Forensic Sconces 45 (2000), 93-98. [Pg.614]

A large number of methods and accessories have been developed to permit the infrared source to interact with the sample in appropriate ways. Some of the more common approaches are listed below. [Pg.422]

The infrared technique has been described in numerous publications and recent reviews were published by Davies and Giangiacomo (2000), Ismail et al. (1997) and Wetzel (1998). Very few applications have been described for analysis of additives in food products. One interesting application is for controlling vitamin concentrations in vitamin premixes used for fortification of food products by attenuated total reflectance (ATR) accessory with Fourier transform infrared (FTIR) (Wojciechowski et al., 1998). Four vitamins were analysed - Bi (thiamin), B2 (riboflavin), B6 (vitamin B6 compounds) and Niacin (nicotinic acid) - in about 10 minutes. The partial least squares technique was used for calibration of the equipment. The precision of measurements was in the range 4-8%, similar to those obtained for the four vitamins by the reference HPLC method. [Pg.130]

Of the analytical techniques available for process analytical measmements, IR is one of the most versatile, where all physical forms of a sample may be considered - gases, liquids, solids and even mixed phase materials. A wide range of sample interfaces (sampling accessories) have been developed for infrared spectroscopy over the past 20 to 30 years and many of these can be adapted for either near-lme/at-lme production control or on-line process monitoring applications. For continuous on-line measurements applications may be limited to liquids and gases. However, for applications that have human interaction, such as near-line measurements, then all material types can be considered. For continuous measurements sample condition, as it exists within the process, may be an issue and factors such as temperature, pressure, chemical interfer-ants (such as solvents), and particulate matter may need to be addressed. In off-line applications this may be addressed by the way that the sample is handled, but for continuous on-line process applications this has to be accommodated by a sampling system. [Pg.157]

Samples of both fulvic and humic acids were suspended in methanol and methylated with diazomethane. Both H and spectra of the free acids were obtained, at 299.94 MHz and 75.42 MHz respectively, on a Varian XL-300 spectrometer having a Nicolet TT-100 PET accessory. Spectra were obtained in D2O, in a 12-mm tube, with deuterated TSP (sodium 3-(trimethylsilyl)propionate-, , 3,3- 4) added as internal reference. GC/MS of methylated acids was conducted on a Hewlett-Packard Model No 5995 GC/MS/DA system equipped with a fused silica capillary column (12 m x. 020 mm ID, Hewlett Packard) internally coated with crosslinked methylene silicone. Infrared spectra were obtained with solid samples dispersed in KBr pellets, by using a Beckman IR-33 spectrophotometer. The various absorption peaks in IR and NMR were interpreted conventionally (9-10). [Pg.385]

All of the usual sampling techniques used in infrared spectroscopy can be used with FT-IR instrumentation. The optics of the sampling chamber of commercial FT-IR instruments are the same as the traditional dispersive instruments so the accessories can be used without modification for the most part. To make full use of the larger aperature of the FT-IR instrument, some accessories should be modified to accomodate the larger beam. The instrumental advantages of FT-IR allow one to use a number of sampling techniques which are not effective using dispersive instrumentation. Transmission, diffuse reflectance and internal reflectance techniques are most often used in the study of epoxy resins. [Pg.76]

Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFT).6 When IR radiation is directed onto the surface of a solid sample, two types of energy reflectance can occur specular and diffuse. The specular component is the radiation that reflects directly off the sample surface (i.e., not absorbed by the sample). Diffuse reflectance is the radiation that penetrates into the sample and then emerges. Diffuse reflectance accessories are designed to optimize the diffuse reflected energy and suppress the specular component. The optics therefore selectively directs the scattered radiation to the IR detector. [Pg.223]

Chemical and instrumental (e.g., chromatography and mass spectrometry) methods have provided valuable information that lead to the advancement of cheese science. However, these techniques suffer from one or more of the following problems (1) the extensive use of solvents and gases that are expensive and hazardous, (2) high costs, (3) the requirement of specific accessories for different analytes, (4) the requirement of extensive sample preparation to obtain pure and clean samples, and (5) labor-intensive operation. These disadvantages have prompted for the evaluation and adoption of new, rapid, and simple methods such as Fourier-transform infrared (FTIR) spectroscopy. Many books are available on the basics of FTIR spectroscopy and its applications (Burns and Ciurczak, 2001 Sun, 2009). FTIR spectroscopy monitors the vibrations... [Pg.196]

The structural and spectral complexity of clay minerals is sufficient to consider a single mineral as a multicomponent mixture in itself. Detectible by near infrared spectroscopy are adsorbed water and structural hydroxyls (25.) exchangeable and structural transition metal cations (2fL and this work), adsorbed species including atmospheric gases (22), organic materials (2) accessory minerals (2SL) and, possibly, trapped hole centers (0 -centers). Thus it is of interest to adapt NIRA to studies of mineral surface activity. We have done this by examination of a small set of highly homologous clays in which laboratory control of only one variable at a time could be accurately achieved and independently confirmed. [Pg.409]

The introduction of Fourier Transform Infrared Spectroscopy (FTIR) brought along a number of typical solid sample techniques. DRIFTS (Diffuse Reflectance Fourier Transform Infrared Spectroscopy) is probably most commonly known. Another technique, developed specifically for measuring solid, opaque samples is PAS (Photo Acoustic Spectroscopy). This accessory is less known, probably due to its high cost and its rather difficult modus operandi. [Pg.491]

Our group was the first to report imaging with a diamond ATR accessory that provided a field of view of ca. 1 mm2 and the spatial resolution of ca. 15 pm without the use of an infrared microscope [18], The demonstration of the applicability of a diamond ATR accessory for FTIR imaging opened up a range of new opportunities in polymer research, from compaction of tablets [21-23] to studying phase separation in polymer blends subjected to supercritical fluids [24], This imaging approach was successfully utilised for the study of dissolution of tablets in aqueous solutions [25], We have also demonstrated macro... [Pg.9]

Determination of Respirable Quartz by Infrared Spectroscopy with a Multiple Internal Reflectance Accessory... [Pg.67]


See other pages where Infrared accessories is mentioned: [Pg.109]    [Pg.109]    [Pg.194]    [Pg.199]    [Pg.201]    [Pg.419]    [Pg.353]    [Pg.167]    [Pg.95]    [Pg.642]    [Pg.740]    [Pg.68]    [Pg.66]    [Pg.318]    [Pg.130]    [Pg.82]    [Pg.274]    [Pg.98]    [Pg.117]    [Pg.471]    [Pg.194]    [Pg.199]    [Pg.201]    [Pg.279]    [Pg.91]    [Pg.79]    [Pg.25]    [Pg.268]    [Pg.6]    [Pg.182]    [Pg.227]    [Pg.253]    [Pg.121]    [Pg.198]    [Pg.23]   
See also in sourсe #XX -- [ Pg.281 ]