Because of the large number of samples and repetitive nature of environmental analysis, automation is very important. Autosamplers are used for sample injection with gc and Ic systems, and data analysis is often handled automatically by user-defined macros in the data system. The high demand for the analysis of environmental samples has led to the estabUshment of contract laboratories which are supported purely by profits from the analysis. On-site monitoring of pollutants is also possible using small quadmpole ms systems fitted into mobile laboratories. [Pg.548]

It is used in IC systems when the amperometric process confers selectivity to the determination of the analytes. The operative modes employed in the amperometric techniques for detection in flow systems include those at (1) constant potential, where the current is measured in continuous mode, (2) at pulsed potential with sampling of the current at dehned periods of time (pulsed amperometry, PAD), or (3) at pulsed potential with integration of the current at defined periods of time (integrated pulsed amperometry, IPAD). Amperometric techniques are successfully employed for the determination of carbohydrates, catecholamines, phenols, cyanide, iodide, amines, etc., even if, for optimal detection, it is often required to change the mobile-phase conditions. This is the case of the detection of biogenic amines separated by cation-exchange in acidic eluent and detected by IPAD at the Au electrode after the post-column addition of a pH modiher (NaOH) [262]. [Pg.409]

Diffusion Scrubber Coupled-Ion Chromatography. Over the past decade, ion chromatography (IC) has become the technique of choice for the determination of anions. Even with conventional sorbent-coated de-nuders for acid gases, the actual determination is most commonly conducted by IC. The recognition of this fact led to the coupled DS--IC system (96). The system is shown schematically in Figure 9. Items A through H constitute... [Pg.84]

Figure 9. Configuration of the DS-IC system A, clean air input B, mass-flow controller C, permeation device chamber D and H, vents E, needle valve-rotameter F, needle valve G, mass-flow meter I, diffusion scrubber Jy scrubber liquid reservoir K, needle valve-rotameter L, suction pump M, injection valve Ny peristaltic pump O, eluent flow F, downstream chromatographic components and Q, sample loop. (Reproduced from reference 96. Figure 9. Configuration of the DS-IC system A, clean air input B, mass-flow controller C, permeation device chamber D and H, vents E, needle valve-rotameter F, needle valve G, mass-flow meter I, diffusion scrubber Jy scrubber liquid reservoir K, needle valve-rotameter L, suction pump M, injection valve Ny peristaltic pump O, eluent flow F, downstream chromatographic components and Q, sample loop. (Reproduced from reference 96.
In all cases examined the ( )-isomers of the allylic alcohols reacted satisfactorily in the asymmetric epoxidation step, whereas the epoxidations of the (Z)-isomers were intolerably slow or nonstereoselective The eryrhro-isomers obtained from the ( )-allylic alcohols may, however, be epimenzed m 95% yield to the more stable ihrco-isomers by treatment of the acetonides with potassium carbonate (6a) The competitive -elimination is suppressed by the acetomde protecting group because it maintains orthogonality between the enolate ic-system and the jK-alkoxy group (cf the Baldwin rules, p 316)... [Pg.265]

A modular micro structured chemical reaction system (ICS) similar to [R 14] is claimed by Bard [84]. The system can use various replaceable and interchangeable cylindrical or rectangular reactors. Generally, the ICS system can include fluid flow handling and control components, mixers, reaction chip-type units, separator devices, process variable detectors and controllers and a computer interface for communicating with the master control center (see Figure 4.31) [84],... [Pg.546]

Some support structures are also included for detachably retaining the various components of the system. Preferably the support structure can be of the assembly board type , which provides prearranged flow channels and connector ports. The desired components of the system can be fastened into these connectors by pins. The flow control system that makes up the ICS system can include pumps, flow channels, manifolds, flow restrictors, valves, etc. These components are equipped with the necessary fittings that allow them to be sealed with the prearranged or selectively located flow channels or connectors. The flow system can also include detachable mixing devices, e.g., static or ultrasonic, or with a chip-like design. The reaction units, whether chip-like or not, can be of thermal, electrochemical, photochemical or pressure type [84]. [Pg.546]

The ICS system, e.g. a kit, provides a reaction system capable ofhandling a variety of reactions by using a reactor unit having a reaction chamber with internal diameters from about 1 pm up to about 1 mm, and more preferably 1-100 pm. In accordance with the internal dimensions, the reaction volumes range from about 1 nl up to about 10 pi [84],... [Pg.547]

The discovery that the flagellum is more complex than first supposed, that it also contains an unpredicted, sophisticated protein-pumping mechanism, and that structures resembling the protein pump can occur independently, briefly set Darwinian hearts aflutter. The innocent optimism was based on Ken Miller s rhetorical redefinition of irreducible complexity, which decreed that parts of IC systems could not have any other function. Since a subset of the flagellum appeared to be part of the TTSS, then that violated Miller s dictum, and cheered some of the more unreflective Darwinists. [Pg.268]

The Stock method is preferable to the classical ous-ic system, for the latter cannot be easily applied to elements with three or more valence states (for example, UCh, UCL, and UCle). [Pg.277]

Various predictive methods based on molecular graphs of ic-systems as described in Section 3 have been critically compared by Klein (Klein et al., 1989) and can be extended to more quantitative treatments. In principle, the effective exchange integrals /ib in the Heisenberg Hamiltonian (4) for the interaction of localized electron spins at sites a and b are calculated as the difference in energies of the high-spin and low-spin states. It was Hoffmann who first tried to calculate the dependence of on the M—L—M bond... [Pg.209]

Very commonly, a target tissue will be stimulated by the S3mipathetic system and inhibited by the paras5mipathet-ic system, or vice versa. Examples are found in table 7.1. Among the paras mipathetic responses listed there, we find stimulation of smooth muscle in the bronchi, and relaxation of smooth muscle in the arterioles both are mediated by muscarinic acetylcholine receptors (cf. Figure 7.6). Here, we have an example of diverse effector mechanisms triggered from similar receptors. Similarly, the adrenergic receptors can operate different intracellular switches as needed. These different effector mechanisms are covered in some more detail in the chapter on G protein-coupled receptors. [Pg.69]

Here, we will also try to promote our own personal view on the possible roadmap to be followed for a rational development of such light-controlled photocatal5d ic systems (3,5,8). The first... [Pg.260]

A mass sensitivity of a chromatogr ic system is that mass of solute (m) that will provide a peak with a height equivalent to twice the noise level. [Pg.95]

The azo group, whose n-electrons are orthogonal to the Tt-system, is more basic than the amino group, whose n-electrons are part of the ic-system. It is protonated before the amino group in acid/ethanol mixtures of increasing acid concentration. [Pg.26]


See other pages where IC system is mentioned: [Pg.494]    [Pg.129]    [Pg.45]    [Pg.46]    [Pg.48]    [Pg.1120]    [Pg.1124]    [Pg.1125]    [Pg.119]    [Pg.91]    [Pg.96]    [Pg.90]    [Pg.94]    [Pg.1213]    [Pg.1213]    [Pg.449]    [Pg.38]    [Pg.38]    [Pg.351]    [Pg.43]    [Pg.260]    [Pg.260]    [Pg.167]    [Pg.17]    [Pg.248]    [Pg.45]    [Pg.46]    [Pg.48]    [Pg.1120]    [Pg.1124]    [Pg.1125]    [Pg.212]    [Pg.606]    [Pg.69]    [Pg.67]    [Pg.409]   