Humidifying systems

If it is variable, set the outside air intake quantity to the winter value. Set the desired temperature up to a maximum, leaving the humidity setting alone. It will be appreciated that as the room temperature rises during the heating test the rh tends to fall. However, since the humidity setting remains unaltered the humidifying system will be called upon to operate until at one condition it is working at peak winter rate. Due to the faster characteristic of heaters, the rh will be found to fall but absolute moisture should be found to steadily rise. The duration of the test is normally about 3 h and final conditions should be held for half an hour to prove the moisture source. [Pg.454]

Consideration can also be given to installing a humidifying system incorporating a biocide spray inside mixing vessels and storage tanks. [Pg.77]

Dust Concentrations Measured in a Textile Mill with Vertical Elutriator Samplers as a Function of Variation in Water in Humidifier System. (25)... [Pg.324]

Fig. 1 Schematic diagram of the multi-layer-packed bed reactor system. I Circuit of air 2 rotameter 3 inlet filter 4 humidifier system 5 reactor (L length ... Fig. 1 Schematic diagram of the multi-layer-packed bed reactor system. I Circuit of air 2 rotameter 3 inlet filter 4 humidifier system 5 reactor (L length ...
So decreasing the temperature from 90 to 70°C actually increases the expected voltage by 15 mV for a fully humidified system because the oxygen mole fraction will increase. There will also be an expected decrease in the exchange current density which can partially or completely offset this trend. However, this example illustrates another issue with operating PEFCs at elevated temperatures where the oxygen mole fraction in a moist system is decreased. [Pg.171]

Acid cleaners based on sulfamic acid are used in a large variety of appHcations, eg, air-conditioning systems marine equipment, including salt water stills wells (water, oil, and gas) household equipment, eg, copper-ware, steam irons, humidifiers, dishwashers, toilet bowls, and brick and other masonry tartar removal of false teeth (50) dairy equipment, eg, pasteurizers, evaporators, preheaters, and storage tanks industrial boilers, condensers, heat exchangers, and preheaters food-processing equipment brewery equipment (see Beer) sugar evaporators and paper-mill equipment (see also Evaporation Metal surface treati nts Pulp). [Pg.64]

Figure 11-69 describes a typical central system. Either water or direct-expansion refrigerant coils or air washers may be used for cooling. Steam or hot-water coils are available for heating. Humidification may be provided by target-type water nozzles, pan humidifiers, air washers, or sprayed coils. Air cleaning is usually provided by cleanable or throwaway filters. Central-station air-conditioning units in capacities up to about 50,000 cu ft/min are available in prefabricated units. [Pg.1105]

Zinc Roasting Sintering Calcining Retorts electric arc Particulates (dust) and SO2 Particulates (dust) and SO2 Zinc oxide fume, particulates, SO2, CO Exhaust system, humidifier, cyclone, scrubber, electrostatic precipitator, and acid plant Exhaust system, humidifier, electrostatic precipitator, and acid plant Exhaust system, baghouse, scrubber or acid plant... [Pg.2177]

Diy systems, where the gas stream is humidified and chemicals are added to the system... [Pg.2252]

Figure 2-41. Heated and humidified eompressed air injeetion system for power augmentation of a gas turbine. Figure 2-41. Heated and humidified eompressed air injeetion system for power augmentation of a gas turbine.
The concept of injecting humidified and heated compressed air just after the gas turbine compressor is another very interesting way to increase power and efficiency. In this system, compressed air is added to the compressed discharge air. The compressed air is about 5% of the main gas turbine air and this air after it has been compressed using an external compressor is then injected into an air saturation device where steam obtained from the HRSG unit is then injected into the device to saturate the air with water and the saturated air then is further heated in the HRSG before it is injected into the compressor discharge of the gas turbine. [Pg.108]

Humidified Compressed Air Injeetion System are about the same. This is due to the faet that though the initial eost to install the Compressed Air System, for a turbine of about 100 MW, is about 3.7 million as compared to about 1.7 million for a steam injection system, the power generated by the Heated and Humidified Compressed Air Injection System is much higher. [Pg.109]

Injection Pre.s.sure. The injeetion pressure must be between 75-100 psia (5-7 Bar) above the Compressor Diseharge Pressure. In the ease of the Heated and Humidified Compressed Air injeeted system, the air must be saturated. [Pg.110]

NOx Emissions. The amount NO emissions is very eritieal in most regions where gas turbines are being utilized for power generation. The present eap is about 22 ppm the aim is to go down to as low as 9 ppm. The teehniques offered here all are NOx emission friendly, in that they do not inerease the present levels of NOx, in faet in the ease of the injeetion systems, both steam, and heated and humidified eompressed air will lower the NOx emissions making the plant even more environmentally friendly, espeeially in this eritieal loea-tion. [Pg.110]

Control Systems. The eosts in all these systems have taken into aeeount modifieations of the eontrol systems. The eontrol systems in most of these eases will have to be new to take into aeeount the injeetion of steam, and the heated and humidified eompressed air, the HRSG, and all its assoeiated equipments sueh as pumps. [Pg.110]

Cleaning solutions Tobacco smoke Air-conditioning systems Water treatment Humidifiers Disinfectants Exhaled breath Vehicle exhausts Smoking chimneys Portable heaters Tobacco smoke Gas cookers Gas and oil heaters... [Pg.142]

Humidification can be achieved by placing separate humidifiers directly in the conditioned space. In order to maintain the design conditions, however, humidity control should be incorporated into the system. When positioning humidifiers, care has to be taken to ensure that the leaving moisture does not impinge on adjacent surfaces, forming lime or algae deposits. [Pg.721]

The influence of airflows from ventilating systems must also be considered. Processes using mediums of different physical qualities when mixed will have separation into different layers. Transmission of energy between molecules in flowing mediums takes place in the direction of the velocity. This strengthens the separation into parallel layers. The level of fluid in containers and tanks is due to stratification of horizontal temperature layers, while airflow after batteries, heat-recovery systems, and humidifiers or dehumidifiers will separate into parallel layers. [Pg.778]

FIGURE 9.57 A ventilation system for controlling the air temperature by humidifying and dehumidifying the air. [Pg.781]

HVAC The heating, ventilation and air conditioning system that circulates and delivers filtered, humidified or dehumidified, and cooled or warmed air to the interior of a building. [Pg.1449]

Condensation of water on cool indoor surfaces (e.g., windows) may damage materials and promote the growth of microorganisms. The presence of humidifiers in commercial building HVAC systems has been associated with an increase in various respiratory health symptoms. [Pg.57]

Where dust control is important the system should only be used with a supply of demineralized water to avoid solids being passed into the conditioned space. The temperature of the air must be sufficient to hold the quantity of moisture being supplied, any excess being deposited in the duct. Unless drained away, this can give rise to corrosion and to incorrect control by re-evaporation when the humidifier is switched off under control. [Pg.452]


See other pages where Humidifying systems is mentioned: [Pg.1097]    [Pg.255]    [Pg.8]    [Pg.234]    [Pg.477]    [Pg.354]    [Pg.489]    [Pg.531]    [Pg.289]    [Pg.362]    [Pg.367]    [Pg.438]    [Pg.1097]    [Pg.255]    [Pg.8]    [Pg.234]    [Pg.477]    [Pg.354]    [Pg.489]    [Pg.531]    [Pg.289]    [Pg.362]    [Pg.367]    [Pg.438]    [Pg.461]    [Pg.261]    [Pg.281]    [Pg.516]    [Pg.471]    [Pg.1182]    [Pg.1593]    [Pg.1599]    [Pg.2372]    [Pg.104]    [Pg.189]    [Pg.611]    [Pg.1264]    [Pg.23]    [Pg.532]   