Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Boilers industrial

J. D. Me Kenna, J. C. Mycock, and W. O. Lipscomb, "Applying Eabric Edtration to Coal Eired Industrial Boilers A Pilot Scale Investigation,"... [Pg.418]

S CAW-OX PEES 35% Catalj d Hjdra ne Solution for Corrosion Protection in Industrial Boilers, Olin Corp., Stamford, Coim., 1987. [Pg.295]

Acid cleaners based on sulfamic acid are used in a large variety of appHcations, eg, air-conditioning systems marine equipment, including salt water stills wells (water, oil, and gas) household equipment, eg, copper-ware, steam irons, humidifiers, dishwashers, toilet bowls, and brick and other masonry tartar removal of false teeth (50) dairy equipment, eg, pasteurizers, evaporators, preheaters, and storage tanks industrial boilers, condensers, heat exchangers, and preheaters food-processing equipment brewery equipment (see Beer) sugar evaporators and paper-mill equipment (see also Evaporation Metal surface treati nts Pulp). [Pg.64]

Carhon dioxide Fuel comhustion calcining Industrial boilers, cement and hme produc- Greenhouse gas... [Pg.2174]

An excellent brief exposition of industrial boilers is presented as Chapter 8 of Combustion—Fo.s.sil Power, Singer (ed.), 4th ed., Combustion Engineering, Windsor, Conn., 1991. [Pg.2397]

Design Criteria Industrial-boiler designs are tailored to the fuels and firing systems involved. Some of the more important design criteria include ... [Pg.2397]

Limits on flue-gas velocities for gas- or oil-fired industrial boilers... [Pg.2397]

TABLE 27-19 Solid-Waste Fuels Burned in Industrial Boilers... [Pg.2397]

Natural-circulation and convection boiler banks are the basic design features on which a line of standard industrial boilers has been developed to accommodate the diverse steam, water, and fuel requirements of the industrial market. [Pg.2398]

FIG. 27-43 Sankey diagrams for various types of boilers (a) fire-tiihe hoder (b) industrial boiler (c) siibcritical-pressiire boiler (d) supercritical-pressure boiler. [Pg.2398]

Industrial furnaces serve the manufacturing sec tor and can be divided into two groups. Boiler furnaces, which are the larger group and are used solely to generate steam, were discussed earlier in the subsec tion on industrial boilers. Furnaces of the other group are classified as follows by (1) source of heat (fuel combustion or electricity), (2) func-... [Pg.2402]

Let s consider an industrial boiler. You may need at least three of these previous mentioned o-rings just to prevent leaks and drips in a simple hydronie or steam boiler. Raw water comes into the boiler room with pipes, gauges, valves and instrumentation. All these fittings would probably use Nitrile rubber o-ring seals to give long-term leak free service. [Pg.206]

Who would have thought that an industrial boiler would need up to four different o-ring compounds just to heat some water ... [Pg.207]

Typical industrial boiler/steam turbine onsite)... [Pg.373]

Zeitz, R. A., ed. (1997). CIBO Energy Efficiency Handbook. Burke, VA Council of Industrial Boiler Owners. [Pg.757]

An example is the classification scheme used by British Coal, and is common throughout the UK. The scheme divides coals into groups, generally as shown in Table 15.6. The group, grading and modes of preparation of a coal serve to indicate the usage for which the coal is suitable for application with industrial boilers. For grading of coal the nominal sizes are shown as follows ... [Pg.187]

For industrial boilers the mean gas temperature at the furnace exit, or at the entrance to the convection section of the boiler, may be calculated using the relationship ... [Pg.347]

The radiant section of an industrial boiler may typically contain only 10 per cent of the total heating surface, yet, because of the large temperature difference, it can absorb 30-50 per cent of the total heat exchange. The mean temperature difference available for heat transfer in the convective section is much smaller. To achieve a thermally efficient yet commercially viable design it is necessary to make full use of forced convection within the constraint of acceptable pressure drop. [Pg.347]

Correlations for forced convection over tubes in crossflow are complicated by the effect of the tube bank arrangement. For the range of Reynolds numbers likely to be encountered in industrial boilers the following equations may be used ... [Pg.347]

As this covers industrial boilers, only units of 500kg/h of steam, or equivalent hot water, and above will be considered. There are nine categories of boiler available. In order of evaporation these are ... [Pg.349]

Several applications of the shallow-bed system are available for industrial boilers the two most used being the open-bottom shell boiler and the composite boiler. With the open-bottom shell, the combustor is sited below the shell and the gases then pass through two banks of horizontal tubes. [Pg.353]


See other pages where Boilers industrial is mentioned: [Pg.294]    [Pg.178]    [Pg.186]    [Pg.293]    [Pg.526]    [Pg.2244]    [Pg.2356]    [Pg.2394]    [Pg.2397]    [Pg.2397]    [Pg.2397]    [Pg.23]    [Pg.38]    [Pg.118]    [Pg.359]    [Pg.367]    [Pg.405]    [Pg.754]    [Pg.59]    [Pg.343]    [Pg.346]    [Pg.346]    [Pg.347]    [Pg.348]    [Pg.350]    [Pg.352]    [Pg.354]    [Pg.356]    [Pg.358]   
See also in sourсe #XX -- [ Pg.590 ]




SEARCH



Boiler and industrial furnace act

Boiler industry

Boiler industry

Boilers and industrial furnaces

Temperatures, industrial boiler

© 2024 chempedia.info