Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Housing temperature

Careflil material selection is required to prevent brittle failure of tanks at low temperatures. In addition, for tanks where the service temperatures are reduced, it is essential that an engineering analysis be performed to ensure that the tanks are not subject to brittle failure at the house temperature. The tank and vessel codes usually specify allowable materials based on design temperature. Further information about selection of metals for low temperature is available (8). [Pg.318]

Temperature control of the magnetic bearing housing environment is critical to safe operation of turboexpanders. Atlas Copco-Rotoflow has developed several schemes to monitor the bearing housing temperature and maintain it at a safe level. [Pg.342]

Figure 6-9. Pressurized bearing housing temperature control. Figure 6-9. Pressurized bearing housing temperature control.
Unless otherwise specified, pump bearings shall be grease Inbricated. The stabilized bearing housing temperature shall not exceed 82°C (180°F) when operated at an ambient temperature of 43°C (110°F). Recommended greases shall be snitable for operation at these tempera-tnres. [Pg.64]

The phase of gene expression in peripheral tissues of intact animals can also be inverted by temperature, by exposing animals to cold days and hot nights (the contrary of what is usually encountered in natural habitats) to reverse the pattern of body temperature in these animals. These experiments are, however, somewhat more difficult to interpret, since the external housing temperature influences... [Pg.97]

Tanks with vent hlters must be designed for pressures of -20 kPa and +100 kPa and must be equipped with a rupture disk. Tanks for hot loop and steam sterilizable line must be designed to withstand steam sterilization (121°C). A steam jacketed sterile vent hlter must be used to avoid condensation in the hlter and the vent hlter housing temperature controlled. The tank for hot storage is steam jacketed and insulated for temperature maintenance. Minimum instrumentation shall include level indication, temperature recording controller, pressure gauge, and pressure relief valve. [Pg.64]

Koizumi A, Wada Y, Tuskada M, et al. A tumor preventive effect of dietary restriction is antagonized by a high housing temperature through deprivation of torpor. Mech Ageing Dev 1996 92 67-82. [Pg.234]

Jin YH, Koizumi A. Decreased cellular proliferation by energy restriction is recovered by increasing housing temperature in rats. Mech Ageing Dev 1994 75 59-67. [Pg.234]

The temperatures reflect only the housing temperatures and not the fluid temperatures inside the pipes. It is nevertheless a strong hint that a thermal separation of different plant sections is possible. Here, the left heated section is separated from the colder right section, as the PTFE element (second element from the left) aollows the development of a sufficiently large temperature gradient of approximately 20 °C in this example. [Pg.558]

If the house temperature is to be maintained at a constant value, what is the rate of energy that must be provided by the heating system in the house ... [Pg.507]

Kentucky Coal (1.0 Percent Sulfur) and West Virginia Coal (3.1 Percent Sulfur). Two tests were conducted with a Kentucky coal containing 1.0 percent sulfur, and six tests were conducted with a West Virginia coal containing 3.1 percent sulfur. Bag-house temperature was maintained at 400-420°F, and the cycle times were either 15 or 30 minutes. [Pg.362]

A cross-sectional view of one cell assembly of the differential photoacoustic apparatus is shown in Fig. 9. Optical access to the sample solution contained in a 1-cm cuvette (an all-quartz modification of a cuvette from Hellma Cell Inc. No. 221, which reduces the probability of cell fracture) is provided by 6.4 mm apertures in a thermostated aluminium housing. Temperature control is provided by four cartridge heaters (Hot Watt, 100 W/120 V) mounted at the four corners of the aluminium block and connected in series to a 10 A/120 V triac (LOVE Controls Corp). The power output of the triac is controlled by a proportional, integral,... [Pg.151]

Chickens raised commercially for broilers are raised in flocks of up to 100,000 or more in a single poultry house. Temperatures inside these houses sometimes rise to intolerable levels during the heat of summer, and many birds die as a result. [Pg.303]

The predicted power loss was somewhat lower than that which was measured experimentally. This may be attributed to the neglect in the analysis of the contribution to the power loss from the upper half of the bush, the groove Inlet and outlet regions and the churning of the oil by the ring. The lower predicted housing temperatures, however, were consistent with the lower predicted power loss. [Pg.584]

Upper pump housing temperature Foreline pressure Processing chamber pressure... [Pg.114]

Example 20.3-3 The effect of insulation Insulation advertisements claim that, in Minnesota, we can save 40% on our heating bills by installing 10 in of glass wool as insulation. The glass wool has a thermal conductivity of about 0.03 Btu/hr ft°F the average winter temperature in Minnesota is 15°F, and the house temperature is 68 °F. If the advertisements are true, and if heat loss from doors and windows is minor, how much can we save with 2 ft of insulation ... [Pg.583]


See other pages where Housing temperature is mentioned: [Pg.342]    [Pg.343]    [Pg.1298]    [Pg.57]    [Pg.87]    [Pg.97]    [Pg.23]    [Pg.219]    [Pg.156]    [Pg.192]    [Pg.174]    [Pg.155]    [Pg.97]    [Pg.109]    [Pg.94]    [Pg.529]    [Pg.267]    [Pg.268]    [Pg.51]    [Pg.371]    [Pg.371]    [Pg.64]   
See also in sourсe #XX -- [ Pg.97 ]




SEARCH



Housing temperature sensors

© 2024 chempedia.info