Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Gravity time

For viscous dominated flows, it can be assumed that the gas inertia and the gas gravitational forces are negligible. By dropping the gas inertia and gravity time from the gas momentum equation and simplifying the dimensionless drag coefficient to the linear viscous term, the set of dimensionless equations does not include gas-to-solid density ratio as a parameter. [Pg.53]

A low-resolution mass measurement is a simple procedure and can be performed with most of the mass spectrometric systems discussed in Chapter 3. The instrument is set up at a resolving power (RP) above 1000. At this low resolving power, the molecular ions of most organic compounds that differ by a unit mass are well separated. The mass spectrometer is first mass-calibrated with an external calibration procedure. During the calibration scan, the computer stores the peak centroid (the center of gravity) time and the area of each peak. The mass of the ion is related exponentially to the peak centroid time ... [Pg.198]

Figure2.2 Evolution ofthe homogeneous reaction time, diffusion time, conduction time, surface tension time and gravity time with respect to the characteristic dimension from the microscale up to the pilot scale (properties of aqueous solutions and water/air surface tension). Figure2.2 Evolution ofthe homogeneous reaction time, diffusion time, conduction time, surface tension time and gravity time with respect to the characteristic dimension from the microscale up to the pilot scale (properties of aqueous solutions and water/air surface tension).
A-3.2. The longitudinal stability of a counterbalanced powered industrial truck depends on the vehicle s moment and the load s moment. In other words, if the mathematic product of the load moment (the distance from the front wheels, the approximate point at which the vehicle would tip forward) to the load s center of gravity times the load s weight is less than the vehicle s moment, the system Is balanced and will not tip forward. However, if the load s moment is greater than the vehicle s moment, the greater load-moment will force the truck to tip forward. [Pg.596]

Because of their widespread use for simple process control, hydrometers are frequently calibrated, not in specific gravity, but in some units related to it, which bear (or bore at one time) some relationship to the concentration being so measured. [Pg.211]

Apolar stationary phases having no dipolar moments, that is their center of gravities of their positive and negative electric charges coincide. With this type of compound, the components elute as a function of their increasing boiiing points. The time difference between the moment of injection and the moment the component leaves the column is called the retention time. [Pg.21]

In high permeability reservoirs, wells may produce dry oil for a limited time following a shut-in period, during which gravity forces have segregated oil and water near the wellbore. In fields with more production potential than production capacity, wells can be alternately produced and shut in (intermittentproduction) to reduce the field water cut. This may still be an attractive option at reduced rates very late in field life, if redundant facilities can be decommissioned to reduce operating costs. [Pg.362]

The first form of aerosol modifier is a spray chamber. It is designed to produce turbulent flow in the argon carrier gas and to give time for the larger droplets to coalesce by collision. The result of coalescence, gravity, and turbulence is to deposit the larger droplets onto the walls of the spray chamber, from where the deposited liquid drains away. Since this liquid is all analyte solution, clearly some sample is wasted. Thus when sensitivity of analysis is an issue, it may be necessary to recycle this drained-off liquid back through the nebulizer. [Pg.152]

If digital voltage readings (V1-V9) are taken at time intervals (At = 0.0001 sec in the example of Figure 44.4), then the area of the true peak (dotted) can be (mathematically) closely approximated to give ion abundance and, similarly, the time (tj to the center of gravity (centroid) of the peak can be determined, thereby giving the m/z value. [Pg.321]

Since the radial acceleration functions simply as an amplified gravitational acceleration, the particles settle toward the bottom -that is, toward the circumference of the rotor-if the particle density is greater than that of the supporting medium. A distance r from the axis of rotation, the radial acceleration is given by co r, where co is the angular velocity in radians per second. The midpoint of an ultracentrifuge cell is typically about 6.5 cm from the axis of rotation, so at 10,000, 20,000, and 40,000 rpm, respectively, the accelerations are 7.13 X 10, 2.85 X 10 , and 1.14 X 10 m sec" or 7.27 X 10, 2.91 X 10, and 1.16 X 10 times the acceleration of gravity (g s). [Pg.635]

Variations in the Force Due to Gravity. The mass of an object is the quantity of matter ia the object. It is a fundamental quantity that is fixed, and does not change with time, temperature, location, etc. The standard for mass is a platinum—iridium cylinder, called the International Kilogram, maintained at the International Bureau of Weights and Measures, ia Snvres, France. The mass of this cylinder is 1 kg by definition (9). AH national mass standards are traceable to this artifact standard. [Pg.330]

The two procedures primarily used for continuous nitration are the semicontinuous method developed by Bofors-Nobel Chematur of Sweden and the continuous method of Hercules Powder Co. in the United States. The latter process, which uses a multiple cascade system for nitration and a continuous wringing operation, increases safety, reduces the personnel involved, provides a substantial reduction in pollutants, and increases the uniformity of the product. The cellulose is automatically and continuously fed into the first of a series of pots at a controlled rate. It falls into the slurry of acid and nitrocellulose and is submerged immediately by a turbine-type agitator. The acid is deflvered to the pots from tanks at a rate controlled by appropriate instmmentation based on the desired acid to cellulose ratio. The slurry flows successively by gravity from the first to the last of the nitration vessels through under- and overflow weirs to ensure adequate retention time during nitration. The overflow from the last pot is fully nitrated cellulose. [Pg.14]

Iodine vapor is characterized by the familiar violet color and by its unusually high specific gravity, approximately nine times that of air. The vapor is made up of diatomic molecules at low temperatures at moderately elevated temperatures, dissociation becomes appreciable. The concentration of monoatomic molecules, for example, is 1.4% at 600°C and 101.3 kPa (1 atm) total pressure. Iodine is fluorescent at low pressures and rotates the plane of polarized light when placed in a magnetic field. It is also thermoluminescent, emitting visible light when heated at 500°C or higher. [Pg.360]


See other pages where Gravity time is mentioned: [Pg.998]    [Pg.359]    [Pg.46]    [Pg.33]    [Pg.1036]    [Pg.1036]    [Pg.767]    [Pg.2]    [Pg.57]    [Pg.998]    [Pg.359]    [Pg.46]    [Pg.33]    [Pg.1036]    [Pg.1036]    [Pg.767]    [Pg.2]    [Pg.57]    [Pg.69]    [Pg.89]    [Pg.205]    [Pg.209]    [Pg.227]    [Pg.361]    [Pg.122]    [Pg.475]    [Pg.1481]    [Pg.1490]    [Pg.466]    [Pg.856]    [Pg.8]    [Pg.9]    [Pg.319]    [Pg.635]    [Pg.98]    [Pg.394]    [Pg.404]    [Pg.389]    [Pg.396]    [Pg.81]    [Pg.78]    [Pg.551]    [Pg.379]    [Pg.238]    [Pg.324]   


SEARCH



© 2024 chempedia.info