Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

GENERAL INDEX polymers

In general, the first step in virtual screening is the filtering by the application of Lipinski s Rule of Five [20]. Lipinski s work was based on the results of profiling the calculated physical property data in a set of 2245 compounds chosen from the World Drug Index. Polymers, peptides, quaternary ammonium, and phosphates were removed from this data set. Statistical analysis of this data set showed that approximately 90% of the remaining compounds had ... [Pg.607]

Grades of PP of melt index 3 were employed in these studies of general-purpose polymers and special high heat ageing stabilisation. Additional studies are discussed involving pigmented materials incorporating various UV stabilisers. In these latter studies these PP... [Pg.363]

Refractive Index. The effect of mol wt (1400-4000) on the refractive index (RI) increment of PPG in ben2ene has been measured (167). The RI increments of polyglycols containing aUphatic ether moieties are negative drj/dc (mL/g) = —0.055. A plot of RI vs 1/Af is linear and approaches the value for PO itself (109). The RI, density, and viscosity of PPG—salt complexes, which maybe useful as polymer electrolytes in batteries and fuel cells have been measured (168). The variation of RI with temperature and salt concentration was measured for complexes formed with PPG and some sodium and lithium salts. Generally, the RI decreases with temperature, with the rate of change increasing as the concentration increases. [Pg.354]

Ethyl Vinyl Ether. The addition of ethanol to acetylene gives ethyl vinyl ether [104-92-2] (351—355). The vapor-phase reaction is generally mn at 1.38—2.07 MPa (13.6—20.4 atm) and temperatures of 160—180°C with alkaline catalysts such as potassium hydroxide and potassium ethoxide. High molecular weight polymers of ethyl vinyl ether are used for pressure-sensitive adhesives, viscosity-index improvers, coatings and films lower molecular weight polymers are plasticizers and resin modifiers. [Pg.416]

The flow process in an injection mould is complicated by the fact that the mould cavity walls are below the freezing point of the polymer melt. In these circumstances the technologist is generally more concerned with the ability to fill the cavity rather than with the magnitude of the melt viscosity. In one analysis made of the injection moulding situation, Barrie showed that it was possible to calculate a mouldability index (p.) for a melt which was a function of the flow parameters K and the thermal diffusivity and the relevant processing temperatures (melt temperature and mould temperature) but which was independent of the geometry of the cavity and the flow pattern within the cavity. [Pg.170]

Synthetic, nonionic polymers generally elute with little or no adsorption on TSK-PW columns. Characterization of these polymers has been demonstrated successfully using four types of on-line detectors. These include differential refractive index (DRI), differential viscometry (DV), FALLS, and MALLS detection (4-8). Absolute molecular weight, root mean square (RMS) radius of gyration, conformational coefficients, and intrinsic viscosity distributions have... [Pg.562]

In general, the multiphasic heterogenous nature of the impact grade styrene-based polymers is the root cause of their opaque-turbid nature. In determining the transparency of the blends, size and the size-distribution pattern of the dispersed phase along with the refractive index difference between the continuous and the dispersed phases are two very important criterion [133]. [Pg.659]

General Polymers issues a monthly newsletter, Cyclelhne Tips, which contains technical tips on processing, tool design, etc. The current and past issues of CycleTime Tips may be accessed from the General Polymers webpage (http //www.ashchem.com/ home/index.asp nav id=4 sub nav=4)... [Pg.628]

The refractive index detector, in general, is a choice of last resort and is used for those applications where, for one reason or another, all other detectors are inappropriate or impractical. However, the detector has one particular area of application for which it is unique and that is in the separation and analysis of polymers. In general, for those polymers that contain more than six monomer units, the refractive index is directly proportional to the concentration of the polymer and is practically independent of the molecular weight. Thus, a quantitative analysis of a polymer mixture can be obtained by the simple normalization of the peak areas in the chromatogram, there being no need for the use of individual response factors. Some typical specifications for the refractive index detector are as follows ... [Pg.185]

This statement can be proved very easily by considering four different types of general POP properties and their variability as a function of the side substituents on the polymer skeleton, i.e. glass transition temperature (Tg), morphology, solvent solubility and limiting oxygen index (LOI). The values of these parameters are reported in Tables 5-8. [Pg.188]


See other pages where GENERAL INDEX polymers is mentioned: [Pg.216]    [Pg.216]    [Pg.588]    [Pg.540]    [Pg.141]    [Pg.446]    [Pg.654]    [Pg.52]    [Pg.225]    [Pg.46]    [Pg.588]    [Pg.1072]    [Pg.403]    [Pg.258]    [Pg.125]    [Pg.469]    [Pg.245]    [Pg.372]    [Pg.390]    [Pg.60]    [Pg.154]    [Pg.434]    [Pg.458]    [Pg.491]    [Pg.217]    [Pg.226]    [Pg.235]    [Pg.516]    [Pg.543]    [Pg.1110]    [Pg.575]    [Pg.112]    [Pg.162]    [Pg.174]    [Pg.375]    [Pg.376]    [Pg.267]    [Pg.245]    [Pg.119]    [Pg.7]   
See also in sourсe #XX -- [ Pg.279 ]




SEARCH



General index

Polymer , generally

Polymers INDEX

© 2024 chempedia.info