Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

General Construction Principles

Depending on the ion-sensitive material used, one can following recent lUPAC recommendations distinguish between [Pg.49]

Due to the relatively poor electrical conductivity of these electrode materials, the thinnest possible layers are used, and they are thus called membrane electrodes. The word membrane, however, should not lead to the erroneous assumption that one is dealing with membrane thicknesses of biological dimensions. Depending on the resistance of the particular material, the membrane thickness can vary considerably 0.1 mm for gjass, 1 to 5 nun for organic materials, and greater than 3 mm for single crystal and pressed pellet electrodes. [Pg.49]

The problem of how to transmit, unaltered, the potential of the ion-sensitive phase still remains. It is not always possible to simply imbed one end of the instrument lead in the material which carries out the specific ion exchange with the test solution. In this case an additional phase boundary, with its own potential, must be introduced into the measuring circuit. In order for a constant equilibrium Galvani potential to arise at this interface, a reversible reaction is required. This contact point must also behave like an unpolarizable electrode, a requirement which is not as easily fulfilled. One already has, however, a reversible and unpolarizable electrode reaction on the measuring side of the membrane (otherwise the electrode response would not follow the Nemst equation). The obvious solution, then, is to allow the same electrode reaction to occur on the inner side of the membrane, only this time with a constant activity of the corresponding measured ion. [Pg.49]

Thus the problem of how to further transmit the potential from the interior of the ion-selective phase is solved, insofar as one can be content with an additional, stable Galvani potential at this new interface. Meanwhile, the same problem exists with this new inner solution phase as that which we encountered in the measurement of a single potential difference namely, how does the potential of this inner solution get to the input terminal of the voltmeter Once again there is no choice other than to be content with the construction of an additional interface and the inclusion of yet another potential difference. Again, care must be taken that the Galvani potential here is also stable. This can be accomplished, as we have seen before with a refer- [Pg.49]

In a few cases (for example with some solid-state membrane electrodes) it is possible to keep unpolarizable the inner contact point to the ion meter, where the crossover from ion conduction to electron conduction occurs (reversible redox reaction). Such solid-state contacts eliminate the need for inner solutions with constant ion activities, and are thus practically maintenance-free. To be sure, with constructions of this type one must keep in mind that there is no longer a compensating inner reference electrode. The temperature dependence of a cell containing such an electrode may be entirely different from that of a symmetric cell in addition, the polarizability can be larger. There is much freedom possible in the design of individual electrode shapes (see Fig. 21). [Pg.50]


The experimental setup used to study the reactions H + O2/H2O/CO2 is outlined in detail elsewhere [28], and general construction principles of flow systems to be used in combination with laser detection techniques can be found e.g. in [29], so only a brief description will be given in the following. [Pg.16]

Analysis of the 1D Correlation Function. Several publications describe the search for a simple graphical analysis [22,159,162-164] of the ID correlation function by means of a geometrical construction. It is the drawback of all such methods that polydispersity and heterogeneity are not considered. The methods are derived from the general generation principle of correlation functions (Fig. 8.20), resulting in equations (cf. Eqs. (8.23), (8.70) and (8.64)) for the first off-origin maximum, the depth of the first minimum or the initial slope iid (0) of ideal correlation functions. For the simplified case of a lamellar system we obtain... [Pg.159]

The General Series Expansion for Stacks. In practice, ID scattering intensities can always be modeled by programming the obvious series expansion of such a structural entity every correlated distance along the stack axis is producing an attenuated oscillation according to Hk (5) that is weighted by the probability of its occurrence under consideration of the zero-sum rule and the related correlation-construction principle (p. 158, Fig. 8.30)... [Pg.195]

D. Overall construction principle. Once the requirements of cell area (ab) to be viewed, the spectral resolution AX and the dispersion on the detector channels are established and the general principles on the choice of optical elements are defined, it is possible to implement the overall construction design (Fig. 1). [Pg.276]

Previous discussions of multiplicity adjusted testing of gene expressions, by Dudoit et al. (2002) and (2003), for example, generally took a nonmodeling approach. Because the joint distribution of the test statistics is generally not available with this approach, multiplicity adjustments in these papers tend to be calculated based on conservative inequalities (for example, the Bonferroni inequality or Sidak s inequality) or on a joint distribution of independent test statistics. In contrast, here, we describe multiplicity adjustment based on the actual joint distribution of the test statistics. However, before describing such adjustments, we first address the construction principles to which all multiple tests should adhere, regardless of the approach taken. These principles do not appear to be as well known in the field of bioinformatics as they are in clinical trials. [Pg.146]

Gr will arise merely as consequences of a Construction Principle (CP) and of the maximum randomness size-assignation procedure applied to simulate the network from these distributions. Second, a general Monte Carlo methodology will be implemented to represent three-dimensional (3D) networks where H, Co, C and Gr coexist. Third, a simulation of the condensation-evaporation characteristics of a fluid within the simulated 3D networks will be performed. [Pg.122]

Introduction General Construction Basic Principles of Operation Key Fiber Properties Fiber Manufacturing ... [Pg.875]

General physical principles of constructing hybrid QM/MM approaches state that the subsequent derivation of junction between quantum and classical subsystems requires a QM wave function underlying the MM description of PESs. This QM method is necessary, for example, to perform averaging of the effective Hamiltonian in Eq. (7). At the same time more important that this method should produce in a consistent manner one-electron states necessary for explicit formation of boundary and its response on the changes in molecular geometry of fragments and/or electronic structure of the i -subsystem. [Pg.217]

The general construction of the lead-acid automotive or starting lighting ignition (SLI) battery using the above principles is shown in Figure 10.1. [Pg.168]


See other pages where General Construction Principles is mentioned: [Pg.55]    [Pg.49]    [Pg.55]    [Pg.49]    [Pg.105]    [Pg.341]    [Pg.67]    [Pg.25]    [Pg.267]    [Pg.457]    [Pg.273]    [Pg.120]    [Pg.341]    [Pg.266]    [Pg.687]    [Pg.307]    [Pg.359]    [Pg.337]    [Pg.631]    [Pg.94]    [Pg.144]    [Pg.399]    [Pg.39]    [Pg.205]    [Pg.12]    [Pg.1273]    [Pg.235]    [Pg.35]    [Pg.675]    [Pg.244]    [Pg.35]    [Pg.211]    [Pg.275]    [Pg.423]    [Pg.56]    [Pg.127]    [Pg.67]    [Pg.9]    [Pg.310]    [Pg.839]    [Pg.308]    [Pg.193]   


SEARCH



Construction principle

General principles

Generality principle

Name construction general principles

© 2024 chempedia.info