Total pathlength

The growth and decay of all other species (including O3) were monitored by Fourier transform infrared (FT-IR) spectroscopy at a total pathlength of 460 meters and a spectral resolution of 1 cm". At this pathlength, the intense absorptions of H2O and CO limit the usable IR spectral windows to the approximate regions 750-1300, 2000-2300, and 2400-3000 cm". Each spectrum (700-3000 cm" ) was adequately covered by the response of the Cu Ge detector. Approximately 40 seconds were required to collect the 32 interferograms co-added for each spectrum. [Pg.118]

It may be seen that the total pathlength for a multi-reflection element with, say, six reflections will range from 13 pm at 800 cm to 3 pm at 3000 cm . Therefore ATR spectra are dependent on the experimental arrangements and apparatus. Other materials for ATR elements are ZnSe, Ge and diamond, with the choice being governed by the refractive index compared with those of the samples being studied. [Pg.219]

The exterior dimensions of the furnace (Figure 14.15) were 11.5 feet x 8.5 feet with a wall thickness of 1 foot. The exterior height of the furnace was nearly 46 feet. Measurements were made through windows on the furnace, which were offset slightly by tubes on the outside of the furnace walls. The total pathlength between furnace windows was 13.2 feet. The beam path transited the furnace directly above the floor-mounted burners, as shown in Figure 14.15. [Pg.325]

The product nv, which has the units of neutrons/(m s) and represents the total pathlength traveled per second by all the neutrons in 1 m, is called the neutron flux ... [Pg.171]

Figure 22.2. Single-beam OP/FT-IR spectrum measured at a resolution of 1 cm over a total pathlength of 218 m. The spectrum was measured when the relative humidity was approximately 30% and the temperature was 13.6°C the intensity of the water lines will be even greater than shown in this spectrum if the pathlength is longer or the humidity is higher. Figure 22.2. Single-beam OP/FT-IR spectrum measured at a resolution of 1 cm over a total pathlength of 218 m. The spectrum was measured when the relative humidity was approximately 30% and the temperature was 13.6°C the intensity of the water lines will be even greater than shown in this spectrum if the pathlength is longer or the humidity is higher.
The determination of acifluorfen in soybean was performed using CE," under the following conditions capillary column (total length 83 cm, 65 cm to the detector, with a 3-mm pathlength, 75-p.m i.d.) absorbance detector, 240 nm capillary oven temperature, 20 °C mnning buffer, 50 mM ammonium acetate buffer (pH, 4.75) applied voltage, 17 kV injection, 0.4 min at 4 mbar migration time, 20 min. [Pg.457]

Fixed pathlength transmission flow-cells for aqueous solution analysis are easily clogged. Attenuated total reflectance (ATR) provides an alternative method for aqueous solution analysis that avoids this problem. Sabo et al. [493] have reported the first application of an ATR flow-cell for both NPLC and RPLC-FUR. In micro-ATR-IR spectroscopy coupled to HPLC, the trapped effluent of the HPLC separation is added dropwise to the ATR crystal, where the chromatographic solvent is evaporated and the sample is enriched relative to the solution [494], Detection limits are not optimal. The ATR flow-cell is clearly inferior to other interfaces. [Pg.491]

As a result, the depth of penetration, or effective pathlength, will be higher the greater X or the smaller the frequency. Therefore, an interferogram (raw infrared spectrum) is a measure of the attenuation of a trans fat test sample of the totally internally reflected infrared light. The interferogram of a reference background material (trans-free fat) is similarly measured. These are subsequently used to obtain an absorption spectrum. [Pg.509]

Figure 3. IR band due to v(H-H) vibration of T 2-H2 in W(CO)5(H2). The spectrum was recorded at ambient temperature with a total pressure (H2 + scXe) of 3000psi and a 1.8 mm optical pathlength. Under these conditions, W(CO)5(H2) has a lifetime of approximately 3 min. The spectrum was recorded whilst the sample was being irradiated with UV light. Figure 3. IR band due to v(H-H) vibration of T 2-H2 in W(CO)5(H2). The spectrum was recorded at ambient temperature with a total pressure (H2 + scXe) of 3000psi and a 1.8 mm optical pathlength. Under these conditions, W(CO)5(H2) has a lifetime of approximately 3 min. The spectrum was recorded whilst the sample was being irradiated with UV light.
Attenuated total internal reflection (ATR) probes offer several advantages over other probe types. ATR is a phenomenon that relies on a difference in the index of refraction of a crystal and that of the solution with which it is in contact to prevent light from escaping the crystal. Only the evanescent wave of the light interacts with the solution layer at the crystal face. The result is an optical pathlength of only a few microns. Typical designs make use of faceted crystals or hemispheres (see Figure 6.1). The most common ATR material in the UV-vis is sapphire. In rare cases, fused silica may be used. ATR allows spectra to be taken of neat samples with optical density (OD) of 500-1000... [Pg.176]

FTIR reflectance and transmission spectroscopy is used for analysis of thin films. Nevertheless, due to the high absorptivities of mid-IR bands, the film thickness must be limited (up to 100 pm, depending on the specific bands chosen) in order to perform an accurate qualitative analysis. Other IR methods, such as attenuated total reflectance (ATR) and photoacoustic methods provide IR spectra of thick material, because they penetrate a very thin layer at the surface of a sample. However, is important to point out that the effective pathlength for the ATR and the photo-acoustic methods depends on the refractive index and thermal diffusivity, respectively. Therefore, the use of these techniques for the quantitative analysis of non-homo-geneous materials can be difficult. [Pg.217]

Transflection is essentially a cross between transmission and reflection. When light is shined onto a reflective surface covered by an optically clear sample, two processes occur - reflection off the top surface of the sample and transmission and reflection off the mirror, followed by a second transmission. As for most materials the surface reflection is low in comparison to the reflection off the mirror, the total collected radiation corresponds to a transmission measurement with double pathlength. Instead of a transparent support, transflection systems require only a spectrally neutral, or at least constant, broadband reflector under the sample. [Pg.161]

Using the data shown below, answer questions a and b The GOT assay was performed in a total volume of 3 ml. The value in parentheses indicates how much the fraction was diluted before using 0.1 ml in the assay. The protein assay was performed by diluting the samples as indicated in parentheses and determining an A2so value in a 1-cm pathlength cuvette. Assume... [Pg.147]


See other pages where Total pathlength is mentioned: [Pg.290]    [Pg.231]    [Pg.618]    [Pg.131]    [Pg.290]    [Pg.231]    [Pg.618]    [Pg.131]    [Pg.450]    [Pg.583]    [Pg.529]    [Pg.78]    [Pg.149]    [Pg.123]    [Pg.132]    [Pg.133]    [Pg.22]    [Pg.79]    [Pg.479]    [Pg.479]    [Pg.636]    [Pg.646]    [Pg.150]    [Pg.223]    [Pg.400]    [Pg.409]    [Pg.421]    [Pg.120]    [Pg.121]    [Pg.211]    [Pg.6]    [Pg.32]    [Pg.90]    [Pg.133]    [Pg.259]    [Pg.255]    [Pg.257]    [Pg.270]    [Pg.58]    [Pg.90]    [Pg.279]   
See also in sourсe #XX -- [ Pg.467 ]