Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

For Additional Information

American Civil Liberties Union ACLU is a freedom network with information and legal resources to fight prohibition and protect the Constitution. (212) 944-9800 http //www.aclu.org [Pg.80]

Anonymous Remailers To learn about the security of the different types [Pg.80]

Austin Nutritional Research Provides information about vitamins, herbs, and nutrients, http //www.realtime.net/anr [Pg.80]

Byrd Labs Laboratories founded by Jeff Nightbyrd. Byrd labs has run more than 2,000 tests on urine and additives. They sell UrineAid, powdered urine, and Conquering the Urine Tests pamphlet. Byrd Products, 1390 North McDowel suite G 337, Petaluma, CA. (800) 333-2152 [Pg.80]

Carson, Ed Book Just Say No to Drug Tests How to Beat the Whiz Quiz. ISBN 0-87364-624-X [Pg.80]


Since this is the first occasion we have had to examine the rates at which chemical reactions occur, a few remarks about mechanistic steps and rate laws seem appropriate. The reader who feels the need for additional information on this topic should consult the discussions which will be found in any physical chemistry text. [Pg.280]

Examples in this table exclude those from tobacco. See references 36 and 37 for additional information. [Pg.538]

Instrumentation. Pilot plants are usually heavily instmmented compared to commercial plants. It is not uncommon for a pilot plant to have an order of magnitude more control loops and analytical instmments than a commercial plant because of the need for additional information no longer requked at the commercial stage. A discussion of all the specific types of instmmentation used on pilot plants is beyond the scope of this article. Further information on some of the more common instmmentation is available (1,51). [Pg.42]

The coupled resonance overlaps with the solvent peaks. For additional information see Refs. 116 and 117. [Pg.258]

The principles of complex variables are useful in the solution of a variety of applied problems. See the references for additional information. [Pg.453]

For additional information, see Simpson (Chem. Eng., 75(6), 192-214 [1968]). A critical Fronde number of 0.31 to ensure vented flow is widely cited. Recent results (Thorpe, 3d Jnt. Conf. Multi-phase Flow, The Hague, Netherlands, 18-20 May 1987, paper K2, and 4th Int. Conf. Multi-phase Flow, Nice, France, 19-21 June 1989, paper K4) show hysteresis, with different critical Fronde numbers for flooding and untlooding of drain pipes, and the influence of end effects. Wallis, Crowley, and Hagi (Trans. ASME J. Fluids Eng., 405 13 [June 1977]) examine the conditions for horizontal discharge pipes to run full. [Pg.655]

U-shaped clevis to which a vaned tailpiece is attac-hed. The wheel rotates because of the difference in drag for the two sides of the cup, and a signal proportional to the revolutions of the wheel is generated. The velocity is determined from the count over a period or time. The current meter is generally usebil in the range of 0.15 to 4.5 m/s (about 0.5 to 15 ft/s) with an accuracy of 2 percent. For additional information see Creager and Justin, Hydroelectric Handbook, 2d ed., Wiley, New York, 1950, pp. 42-46. [Pg.888]

See ANSI B16.5, Table lA, for additional information and notes relating to specific materials. [Pg.985]

Honeywell Specialty Materials, a 3.5 billion strategic business group of the Honeywell Corporation, is a global leader in providing customers with high-performance specialty materials, including fluorocarbons, specialty films and additives, advanced fibers and composites, customized research chemicals, and electronic materials and chemicals. Our products can be found in items you use everyday — at work and at home. For additional information, please visit www.honevwell.com/sites/sm. [Pg.464]

One of the critical measurements is torque or shaft power. A variety of methods is recognized direct methods such as torque meters or reaction mounted drivers (dynamometers) and indirect methods such as electrical power input to drive motors, heat balance, or heat input to a loop cooler. See Part 7, Measurement of Shaft Power, PTC 19.7 1961 [3] for additional information. [Pg.425]

Section C The following Web sites are recommended for additional information... [Pg.333]

The following are Web sites to visit for additional information and calculation... [Pg.215]

The use of any of the above techniques demands knowledge, experience, and flexibility. No prescriptive set of questions or key words or list is sufficient to cover all processes, hazards, and all impacted populations. As a research chemist reviews a chemistry and its potential application, there are advantages to maintaining an open mind when applying the various techniques designed to open up avenues of thought. The reader is referred to Chapter 7 for additional information and direction on the choice of process hazard review techniques. [Pg.63]

Names or regular job titles of persons or departments who can be contacted for additional information or explanation of duties of the plan (emergency call-out list). [Pg.172]

If the item is not resolved, an individual is assigned responsibility for resolving it aftei the session. Requests may be made for additional information. [Pg.88]

Ran Y. Kim, personal communication, 8 April 1981. For additional information, see Ran Y. Kim, On the Off-Axis and Angle-Ply Strength of Composites, in Test Methods and Design Allowables for Fibrous Composites, C. C. Chamis (Editor), Dearborn, Michigan, 2-3 October 1979, ASTM STP 734, American Society for Testing and Materials, 1981, pp. 91-108 (reprinted with permission). [Pg.120]

Equation derived from / SS ASHRAE Handbook of Fundamentals, Chapter 22, assiim-ing an air change every five (5) minutes. Refer to the ASHRAE Handbook, Chapter 22, for additional information on naturally ventilated buildings. [Pg.512]

See Section 5.4.1 for additional information on the use of velocity flame stoppers for hydrogen service. [Pg.97]

As noted in Section 5.3.6, if a flame arrester monnted on a breather vent nozzle of an atmospheric tank becomes plngged, overpressnre may occnr when the tank is filled or a vacnnm may occnr when the tank is emptied. Overpressnre or vacnnm may also be cansed by ambient temperatnre change. See Section 6.1 for additional information. [Pg.116]

Styragel columns are compatible with most solvents commonly used in size exclusion chromatography. Exceptions are found on both sides of the polarity scale the use of standard general-purpose Styragel columns with aliphatic hydrocarbons or with alcohols (except hexafluoroisopropanol) and water is generally not recommended. However, it is possible to pack columns in special solvents for special-purpose applications. The interested user should contact Waters for additional information. [Pg.341]

Many more plume rise equations may be found in the literamre. Table 12.5.2 briefly summarizes some of the equations. For additional information, consult tlie references. [Pg.371]

If some fields may be empty in the sublevels, all the fields in the main level are required for each entry. A new chiral separation record can be added in CHIRBASE solely if the authors correctly identify both sample and CSP. Since the beginning of the project, our policy has been to contact the authors of all publications containing incomplete, ambiguous or inconsistent data and to ask for additional information. Providing the separations with unique case numbers helps us considerably in this essential task, and also facilitates avoiding redundancies in the database. When chiral separations are reported for the second time in a new publication with exactly the same chromatographic conditions, this is stated in a footnote added in the field comments . In this field, miscellaneous information that cannot appear elsewhere are listed (detection limit, description of a reported chromatogram, racemization study, mobile phase limitations, etc.). [Pg.98]

Special reduced manufacturing ranges can be obtained for the STD prebulged metal disk. X, A, and X ranges are available upon request. Please consult your representative or the factory for additional information. [Pg.434]

Note Interpolate for intermediate tank sizes. Tanks with a capacity of more than 180,000 barrels require individual study. Refer to Appendix A for additional information about the basis of this table. [Pg.470]

FPN) For additional information concerning such installations in an industrial or multibuilding complex, see the National Electrical Safety Cock, ANSI C2-1993. [Pg.635]

FPN No. 1) For additional information on the properties and group classification of Class I materials, see Manual for Classification of Gases, Vapors, and Dusts for Electrical Equipment in Hazardous (Classified) Locations, NFPA 497M-1991, and Guide to Eire Hazard Properties ofElammable Liquids, Gases, and Volatile Solids, NFPA 325—1994. [Pg.638]

For additional information on some of the features of the salt spray test and its limitations in respect of certain of the purposes for which it may be used, reference should be made to the book Corrosion Testing for Meta Finishing prepared by the Institute of Metal Finishing. [Pg.1027]


See other pages where For Additional Information is mentioned: [Pg.537]    [Pg.888]    [Pg.888]    [Pg.889]    [Pg.464]    [Pg.257]    [Pg.114]    [Pg.275]    [Pg.326]    [Pg.455]    [Pg.122]    [Pg.20]    [Pg.167]    [Pg.570]    [Pg.142]    [Pg.482]    [Pg.276]    [Pg.3]    [Pg.18]    [Pg.35]    [Pg.60]    [Pg.92]    [Pg.108]   


SEARCH



Additional information

The Necessity for Additional Information

© 2019 chempedia.info