Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Flow Arrangement

Regardless of how achieved, the purpose of adjustment of T is twofold (1) to shift an equilibrium limit, so as to increase fractional conversion or yield, and (2) to maintain a relatively high rate of reaction, to decrease the amount of catalyst and size of vessel required. [Pg.516]

In nonadiabatic operation, heat transfer for control of T is accomplished within the bed itself. This means that the reactor is essentially a shell-and-tube exchanger, with catalyst particles either inside or outside the tubes, and with a heating or cooling fluid flowing in the shell or in the tubes accordingly. [Pg.516]


Solution We wish to avoid as much as possible the production of di- and triethanolamine, which are formed by series reactions with respect to monoethanolamine. In a continuous well-mixed reactor, part of the monoethanolamine formed in the primary reaction could stay for extended periods, thus increasing its chances of being converted to di- and triethanolamine. The ideal batch or plug-flow arrangement is preferred, to carefully control the residence time in the reactor. [Pg.50]

In the cross-flow arrangement, the argon gas flows at high linear velocity across the face of an orthogonal capillary tube containing sample solution. The partial vacuum causes liquid to lift above the end of the capillary. Here, it meets the argon and is nebulized. [Pg.144]

In this cross-flow arrangement, a thin film of sample solution is obtained as it flows around the edge of a small opening, through which there is a fast linear flow of argon. The liquid film is rapidly nebulized along the rim of the orifice. [Pg.145]

For heat exchangers other than the parallel and counterflow types, the basic heat-transfer equations, and particularly the effective fluid-to-fluid temperature differences, become very complex (5). For simplicity, however, the basic heat-transfer equation for general flow arrangement may be written as... [Pg.486]

Fig. 3. The Dorrco Flocculator-Squarex clarifier combination (cross-flow arrangement) (a) plan and (b) sectional elevation. Fig. 3. The Dorrco Flocculator-Squarex clarifier combination (cross-flow arrangement) (a) plan and (b) sectional elevation.
The voltage used for electro dialysis is about 1 V per membrane pair, and the current flux is of the order of 100 A/m of membrane surface. The total power requirement increases with the feedwater salt concentration, amounting to about 10 MW per m product water per 1000 ppm reduction in salinity. About half this power is required for separation and half for pumping. Many plant flow arrangements exist, and their description can be found, along with other details about the process, in References 68 and 69. Many ED plants, as large as 15,000 vsf jd, are in operation, reducing brackish water concentration typically by a factor of 3—4. [Pg.253]

Three commercial processes that use these various hot carbonate flow arrangements are the promoted Benfield process, the Catacarb process, and the Giammarco-Vetrocoke process (26—29). Each uses an additive described as a promoter, activator, or catalyst, which increases the rates of absorption and desorption, improves removal efficiency, and reduces the energy requirement. The processes also use corrosion inhibitors, which aHow use of carbon—steel equipment. The Benfield and Catacarb processes do not specify additives. Vetrocoke uses boric acid, glycine, or arsenic trioxide, which is the most effective. [Pg.21]

In its development, it adapted two existing technologies, In the agricultural sector, the mechanics of grain elevators provided a model for how to move solids vertical distances and in closed-loop flow arrangements. Sacony engineers modified the elevator bucket systems traditionally used by the grain industry to carry hot catalyst from the bottom to top of vessels and between vessels. [Pg.992]

Figure 10-4A(2). Multitube hairpin fintube heat exchangers. The individual shell modules can be arranged into several configurations to suit the process parallel and/or series flow arrangements. The shell size range is 3-16 in. (Used by permission Brown Fintube Co., A Koch Engineering Co., Bui. B-30-1.)... Figure 10-4A(2). Multitube hairpin fintube heat exchangers. The individual shell modules can be arranged into several configurations to suit the process parallel and/or series flow arrangements. The shell size range is 3-16 in. (Used by permission Brown Fintube Co., A Koch Engineering Co., Bui. B-30-1.)...
Figure 10-9A. Spiral flow heat exchanger, cross-flow arrangement for liquids, gases, or liquid/gaseous (condensable) fluids. (Used by permission Alfa Laval Thermal Inc., Bui. 1205 1993.)... Figure 10-9A. Spiral flow heat exchanger, cross-flow arrangement for liquids, gases, or liquid/gaseous (condensable) fluids. (Used by permission Alfa Laval Thermal Inc., Bui. 1205 1993.)...
Figures 10-96A-E illustrate horizontal and vertical thermosiphon reboiler flow arrangements. Figures 10-96A-E illustrate horizontal and vertical thermosiphon reboiler flow arrangements.
Centrifugal compressor cases are classified as horizontally split or vertically split (Figures 12-40A-C). The 5th Edition, April, 1988, API Standard 617 refers to the horizontally split style as Axial Split and vertically split units as Radial Split The first terminology is more standard than that of the API-617. Figure 12-40D illustrates one flow arrangement for back-to-back internal flow, with the following advantages ... [Pg.456]

Pump impellers are further classified as to the inlet flow arrangement such as single suction (which has a single inlet on one side) and double suction (which has a double inlet on each side of the impeller). [Pg.473]

The term bladed refers to raised, continuous flow restrictors with a standoff distance from the bit body of more than 1.0 in. In most cases cutters are affixed to the blades so that the cutter arrangement may also be described as bladed. The term ribbed refers to raised continuous flow restrictors with a standoff distance from the bit body of 1.0 in. or less. Cutters are usually affixed to most of the ribs so that the cutter arrangement may also be described as ribbed. The term open face refers to nonrestricted flow arrangements. Open face flow designs generally have a more even distribution of cutters over the bit face than with bladed or ribbed designs. [Pg.806]

The treatment of experimental data constitutes an essential step in any chemical kinetics study. Although a large part of the present section is based on the investigations in transient flow degradation, the procedure should be general enough to be applicable to other experimental flow arrangements. [Pg.134]

An internally-staged, gas-permeation module is used for the oxygen enrichment of air, using the flow arrangement shown in Fig. 5.206. Enrichment depends on differing membrane permeabilities for the oxygen and nitrogen to be separated. The permeation rates are proportional to the differences in component partial pressures. [Pg.572]

Two shell passes (F shell) are occasionally used where the shell and tube side temperature differences will be unsuitable for a single pass (see Section 12.6). However, it is difficult to obtain a satisfactory seal with a shell-side baffle and the same flow arrangement can be achieved by using two shells in series. One method of sealing the longitudinal shell-side baffle is shown in Figure 12.12/. [Pg.649]

The divided flow and split-flow arrangements (G and J shells) are used to reduce the shell-side pressure drop where pressure drop, rather than heat transfer, is the controlling factor in the design. [Pg.649]

The basic layout and flow arrangement for a gasketed plate heat exchanger is shown in Figure 12.60. Comer ports in the plates direct the flow from plate to plate. The plates are embossed with a pattern of ridges, which increase the rigidity of the plate and improve the heat transfer performance. [Pg.756]

Figure 12.61. Plate heat-exchanger flow arrangements The number of transfer units is given by ... Figure 12.61. Plate heat-exchanger flow arrangements The number of transfer units is given by ...

See other pages where Flow Arrangement is mentioned: [Pg.222]    [Pg.448]    [Pg.145]    [Pg.103]    [Pg.119]    [Pg.1094]    [Pg.1166]    [Pg.1370]    [Pg.1855]    [Pg.2050]    [Pg.71]    [Pg.142]    [Pg.144]    [Pg.146]    [Pg.446]    [Pg.14]    [Pg.306]    [Pg.374]    [Pg.514]    [Pg.23]    [Pg.331]    [Pg.389]    [Pg.60]    [Pg.567]    [Pg.569]    [Pg.569]    [Pg.758]    [Pg.758]    [Pg.758]    [Pg.793]   


SEARCH



Arrangement radial flow reactor

Continuous-flow conveyors feed arrangements

Flow synthesis, reactors arrangement

Liquid-flow arrangement

Packed towers flow arrangements

Plate heat exchangers flow arrangements

Plate heat flow arrangements

© 2024 chempedia.info