Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Floor installation

You do not need to report items that make up the structure of your facility, such as walls any flooring, installation, or wiring. Also, you do not need to report the furnishings in your facility, such as desks, chairs, carpets, and draperies. When completing the survey you do not have to make employees account for their personal possessions, such as matches. If the facility owns and operates a number of vehicles, do not report the gasoline, motor oil, etc. in those vehicles. However, you must report the gas tank you have on site for fueling vehicles, and the motor oil and other reportable supplies you might keep on hand for maintenance. [Pg.192]

GEV EMICODE (2001) Labelling Scheme for Flooring Installation Products including flooring adhesives, primers and levelling compounds http //www.emicode.com/ gev-uk/gev.htm... [Pg.145]

Bostik, Inc., formerly Bostik Findley, Inc., is a leading global producer of adhesives and sealants. The firm operates in five segments construction and distribution performance adhesives nonwovens/tape and label global transportation and flexible laminating. The construction and distribution division manufactures flooring installation adhesives for tile, stone, hardwood, carpet and vinyl caulks, elastic adhesives, aerosol adhesives, fire-retardant adhesives, epoxies,... [Pg.184]

Some safety engineers have become obsessed with fears of safety problems with hot asphalt, although very few injuries or accidents have been traceable to it over the several centuries that it has been used industrially. Asa result, there have been many efforts to substitute cold asphalt putties for hot asphalt as a membrane material. These materials and their limitations have been discussed above. As a membrane for floor installations, such putties are often usable providing they are never subject to a standing liquid head, but less frequently for trenches and pits. Remember, if asphalt emulsions are put in service before all the water has dried out of them, they can reemulsify and may be washed out. [Pg.153]

Life cycle costs include expenses beyond the cost of flooring, installation, and maintenance. [Pg.97]

Acoustic ceiling panels, floor tile and continuous flooring installation Ceramic tile installation Counter top lamination Manufacture of... [Pg.17]

Repair options are detailed in API 653. For floor plate repairs, if local overplating or plate replacement is not deemed appropriate, the original floor plates should be removed and a new floor installed. [Pg.41]

Convenience No need to tear into the wall of and/ or floor. Installation Installation takes around 4 days. Need to tear into some sections of wall for installation Installation takes 5-6 days. [Pg.426]

The main impetus for undertaking failure analysis should not be about blame but to find the root causes and learn from the mistakes. In a very recent inspection of an unsatisfactory floor installation, it would have been all too easy to blame the floor layer for gaps between tiles. However, it was primarily due to variation in tile dimensions and the occurrence of gaps would certainly continue to occur unless dimensional tolerances were tightened. [Pg.4]

Manufocturers Comments 75% solids, <5% solvent. General purpose, high performance flooring installation. Porous and non-porous surhices. Good resistance to wheel-chairs. Specification DTU 53-2. [Pg.70]

Construction SBR Carpet installation, vinyl flooring installation, ceramic tile... [Pg.22]

It also stands to reason that it will be most difficult to achieve a satisfactory bond on concrete that is loose, flaky, or spalled in any way. Occasionally, curing agents have been used in the concrete that may have a tendency to rise to the surface and create salts that are most difficult to bond to. In this event these salts should be removed before attempting to adhere any type flooring material. All cracks or rough areas on the concrete should be patched prior to proceeding with flooring installations. Naturally the surface should also be free of any dust, dirt. [Pg.686]

Fortunately most of the wood floors installed today utilize a very narrow range of adhesives, which greatly simplifies the selection decision. These are as follows ... [Pg.687]

Asphalt cutbacks. Until a few years ago the majority of wood floors installed with... [Pg.687]

It is not uncommon to find flooring materials used as wall covering, for example, wood parquet flooring and carpeting. They require different adhesives from those used on floor installations, with sufficient green strength to hold the flooring material in a vertical position. [Pg.690]

Japan Association of Rolling Stock (2005) Industries standard JRIS R 0206-1 rolling stock-guidelines for rigging design-Part 1 under floor installations, Japan Association of Rolling Stock, Tokyo (in Japanese)... [Pg.1235]


See other pages where Floor installation is mentioned: [Pg.270]    [Pg.120]    [Pg.132]    [Pg.670]    [Pg.670]    [Pg.270]    [Pg.86]    [Pg.436]    [Pg.26]    [Pg.543]    [Pg.662]    [Pg.687]    [Pg.372]   
See also in sourсe #XX -- [ Pg.16 , Pg.17 , Pg.18 , Pg.19 ]




SEARCH



Flooring

Floors/flooring

© 2024 chempedia.info