Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Fitness testing minimization

We also applied conventional all-atom normal modes (via the CHARMM package) for fitting tests on several proteins after initial energy minimization. Oddly, the fitting results are often worse than those for RTB (data not shown), presumably because RTB prevents surface side-chains from undergoing large deviations during initial minimization. [Pg.240]

Logically, the accuracy of parameter estimation using this simulation method depends on the quality of the model function chosen. An inadequate model results in pseudokinetic parameters. The fitting of simulation to experimental data is carried out with the aid of statistical criteria such as the F-test, minimizing deviations erf ... [Pg.167]

Your employer must ensure that your respirator face-piece fits properly. Proper fit of a respirator facepiece is critical to your protection from airborne lead. Obtaining a proper fit on each employee may require your employer to make available several different types of respirator masks. To ensure that your respirator fits properly and that facepiece leakage is minimized, your employer must give you either a qualitative or quantitative fit test as specified in Appendix A of the respiratory protection standard located at 29 CFR 1910.134. [Pg.251]

Very small gaps can create opportunities where particles can go around the filter and directly through that gap between your face and your respirator, Shaffer said, pointing out that it is particularly difficult to get a strong seal around the nose and chin. Fit testing can minimize the gaps, but not completely eliminate them. [Pg.49]

The model was tested against solution polymerization data for MMA reported by Schulz and Haborth (11). The minimization of error in fitting the model to the data resulted in negative values for a. This is physically unrealistic, and suggests that the model needs modification. Further work is intended which will refine the choice of initial condition for application of the model and/or change the inverse dependency of on entanglement density to power greater than unity. [Pg.372]

It was desirable to test for possible inadequacy of the Oj values for certain substituents. This testing has been done with data for several reaction rate and equilibrium series for which both the p- and m- sets meet the minimal basis set requirements. The p and p/ values for the m- and p- positions obtained in preliminary fittings were held as constraints in the data, with the result that both Oj and Or values were generated from best fitting. [Pg.53]

The open-loop test response fitted to a first order with dead time function GPRC can be applied to other tuning relations. One such possibility is a set of relations derived from the minimization of error integrals. Here, we just provide the basic idea behind the use of error integrals. [Pg.106]

There are different ways of testing whether there is continuing improvement of the fit or whether the progress is finished and, hopefully, the best minimal ssq has been reached. In the progress of the iterations, the shifts 8p, as well as the sum of squares, usually decrease continuously. Thus both could be inspected for constancy. The most common and intuitively correct test is the constancy of the sum of squares, as indicated in Figure 4-35. [Pg.153]

All regression methods aim at the minimization of residuals, for instance minimization of the sum of the squared residuals. It is essential to focus on minimal prediction errors for new cases—the test set—but not (only) for the calibration set from which the model has been created. It is relatively easy to create a model— especially with many variables and eventually nonlinear features—that very well fits the calibration data however, it may be useless for new cases. This effect of overfitting is a crucial topic in model creation. Definition of appropriate criteria for the performance of regression models is not trivial. About a dozen different criteria— sometimes under different names—are used in chemometrics, and some others are waiting in the statistical literature for being detected by chemometricians a basic treatment of the criteria and the methods how to estimate them is given in Section 4.2. [Pg.118]

The multilevel coordinate search (MGS) method was used to optimize parameters to get best fit between the experimental and predicted intensities. The NOE R-factor was used as the energy function to be minimized. A version of the MGS method was written based on the version presented by Huyer and Neumaier [65]. The algorithm performs the minimization by a standard coordinate search method. The method was carefully tested by the use of different starting points for the coordinate search and using simulated data sets. This alleviates local minima trapping by MGS, and identifies fhe global minimum within the parameter ranges used in the optimization. [Pg.36]

It dawned on me that perhaps I had been overreaching. Obediently, I rounded up the reluctant docs and we all went out to take the prescribed tests. Not surprisingly, some of us could not even meet the minimal standards of fitness. Once again, an act of hubris predictably came before a fall from grace ... [Pg.159]

Furthermore, optimal design theory assumes that the model is true within the region defined by the candidate design points, since the designs are optimal in terms of minimizing variance as opposed to bias due to lack-of-fit of the model. In reality, the response surface model is only assumed to be a locally adequate polynomial approximation to the truth it is not assumed to be the truth. Consequently, the experimental design chosen should reflect doubt in the validity of the model by allowing for model lack-of-fit to be tested. [Pg.34]

When attempting to convert a manual method into an automated method, there are certain elements, such as tablet size and solvent selection, which will have an impact on the ease of the conversion from manual to automated. For instance, some of the elements of an assay method that would make it easier to automate would be that the dosage form fits into a test tube the extraction uses neutral media or acid not more concentrated than 0.1 M makes use of nonvolatile, low-toxicity solvents does not use surfactants and uses premixed, room-temperature solvents. Some of the elements of a dissolution method that would make it easier to automate would be that the dosage form fits in the sample carousel, does not use media more concentrated than 0.1 M acid, does not use isopropanol or surfactant in large quantities, uses magnetic sinkers or no sinkers at all, and uses no or minimal reagent addition volumes for pH control. [Pg.79]

As test aqueous drinks, two commercial drinks of different brands were chosen. Figure 10 shows the electrical potential patterns of these two drinks. While they are not so different, the discrimination is easy because of standard deviations of 2mV. We attempted to fit the above patterns constructed from eight functions to the output electrical potential pattern of one of commercial drinks (let us call "drink A" for convenience) by minimizing the following value. [Pg.388]

Basic tests, such as hardness, alkalinity, chloride, silica, and phosphate, can generally be undertaken with low-priced simple equipment. The individual methods normally incorporate suitable protocols to minimize interferences. Thus, almost any equipment and any test method can be selected that meets the rule of fitness-for-purpose. (Typically this is a mix of portability, ease of testing, and speed of handling multiple water samples, combined with accuracy, suitable detection limits, price of equipment and replacement reagents, and service company testing protocol uniformity.)... [Pg.373]


See other pages where Fitness testing minimization is mentioned: [Pg.187]    [Pg.336]    [Pg.440]    [Pg.133]    [Pg.574]    [Pg.2202]    [Pg.185]    [Pg.354]    [Pg.49]    [Pg.2330]    [Pg.143]    [Pg.162]    [Pg.161]    [Pg.470]    [Pg.65]    [Pg.166]    [Pg.260]    [Pg.480]    [Pg.71]    [Pg.870]    [Pg.932]    [Pg.109]    [Pg.45]    [Pg.219]    [Pg.62]    [Pg.481]    [Pg.399]    [Pg.49]    [Pg.50]    [Pg.172]    [Pg.109]    [Pg.160]    [Pg.600]    [Pg.49]    [Pg.372]   
See also in sourсe #XX -- [ Pg.1081 ]




SEARCH



Fit testing

Tests minimization

© 2024 chempedia.info