Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Final Recommendations

Protocols and clinical guidelines have already been introduced to the ICUs and should be encouraged. [Pg.89]

An early SB or PSV trial should be repeated daily in difficult-to-wean patients. Weaning protocols are necessary to assist junior physicians, especially in ICUs where staff turnover is high. [Pg.89]

WPs may be especially useful when nonphysician healthcare providers play a major role in weaning or when physician availability is limited. [Pg.89]

WPs should be modified to accommodate the setting, the team, the time used for the application of weaning, and the patient s underlying condition. [Pg.89]

Weaning is only a component of management for patients with complex multiorgan conditions. [Pg.89]


The final recommended configuration for improving dust capture is shown in Fig. 10.46. The design change was rather simple and the model test showed a significant reduction in visible fugitive emissions. [Pg.908]

Pressure drop, final recommended The manufacture recommended operating pressure drop of a filter at rated flow conditions. [Pg.1468]

Contact manufacturer for final recommendations, give complete system requirements, and physical properties of liquid. Figure 3-69 is convenient for this purpose. [Pg.221]

A final recommendation and proposed implementation date are circulated to the relevant regulatory authorities. [Pg.40]

My final recommendation to the customer was to put in a small RC snubber very close to the IC between its SW and GND pins. Typical values of this snubber are 470pF to 4.7nF and 10Q to 100Q. Note that since this Band-Aid fix is very layout and parasitic dependent, I usually ask the customer to try all the corner combinations first, such as 470pF/10Q, 470pF/100Q, and so on. The customer may also need to play with intermediate R and C values to optimize performance and not take too big a hit in efficiency in the process. I know the Japanese customer evaluated the snubber fix at his end and went into full production with it. [Pg.144]

Final Recommendations for Protecting Human Health From Potential Adverse Effects of Exposure to Agents GA (Tabun), GB (Sarin), and VX." Federal Register 68, No. 196 (October 9, 2003) 58348-58351. [Pg.102]

Priority substances were selected, which are considered to be of particular concern to human health and/or the environment. The suppliers of these priority substances had to provide any missing studies to complete a EU notification Base Set (Table 1). A rapporteur Competent Authority evaluates the full review dossier on behalf of the EU. The final output is a risk assessment (see Section 14), with final recommendations on how to deal with the substance i.e., it may be of no concern, require risk reduction or restriction, or further data may be needed before a decision is made. [Pg.6]

A public hearing was held on May 30, 2002, at the Paterson, New Jersey, City Hall to communicate findings and conclusions from this hazard investigation and to gather input from interested parties prior to making final recommendations and issuing a final report. [Pg.292]

At the conclusion of clinical trials, the results are evaluated by the CDE, which submits a report to the DDR. Based on the report, the DDR makes a final recommendation to the Director of the SFDA for approval to import the drug into China. The overall process may take 1-2 years. [Pg.264]

Recommendations Recommendations require careful wording. Before finalizing recommendations, review the report s intended and potential audiences, company protocols, expectations, and past practices. [Pg.271]

NAHWOA 2002. Final Recommendations and Comments. Summary. Network for Animal Health and Welfare in Organic Agriculture, . [Pg.198]

Final recommendations should be sought from companies skilled in the art. Ultimate selection can then be based on field tests with a specific water. [Pg.190]

Some basic design features are the avoidance of sharp bends, a minimum of line fittings, provision for cleanout, and possibly electrical grounding. In many cases equipment suppliers may wish to do pilot plant work before making final recommendations. Figure... [Pg.71]

CDC (Centers for Disease Control and Prevention). 1988. Final Recommendations for Protecting Health and Safety Against Potential Adverse Effects of Long-Term Exposure to Low Doses of Agents GA, GB, VX Mustard Agent (H, HD, T) and Lewisite (L). Federal Register, Vol. 53, No. 50, March 15. [Pg.47]

Finally, recommendations on principles that could be used to exempt radioactive waste from regulatory control as radioactive material have been developed both in the United States (NCRP,... [Pg.210]

Before any final recommendation can be made, the entire application must be considered, from a normal operating situation to extreme conditions, including changes to the material under operating conditions. [Pg.138]

The final recommendations for optimization criteria to be used in the general case (i.e. when all peaks are considered to be of equal importance) are summarized in table 4.11. The table shows recommended criteria for four different cases. Below the dashed line, an alternative criterion (second best choice) is given for each case. [Pg.158]

The target area of AnIML (http //animl.sourceforge.net/) is the handling of analytical data. The teams participating in AnIML development, sanctioned by ASTM under subcommittee E13.15, have not published a final recommendation yet, but the language promises to become one of the most important XML languages in the chemistry field. [Pg.115]

The subject of incremental costs is covered in detail in Chap. 10 (Profitability, Alternative Investments, and Replacements). Consideration of incremental costs shows that a final recommended design does not need to correspond to the optimum economic design, because the incremental return on the added investment may become unacceptable before the optimum point is reached. However, the optimum values can be used as a basis for starting the incremental-cost analyses. [Pg.342]

This chapter deals with methods for determining optimum conditions, and it is assumed that the reader understands the role of incremental costs in establishing a final recommended design. [Pg.342]

The various mathematical methods for determining optimum conditions, as presented in this chapter, represent on a theoretical basis the conditions that best meet the requirements. However, factors that cannot easily be quantitized or practical considerations may change the final recommendation to other than the theoretically correct optimum condition. Thus, a determination of an optimum condition, as described in this chapter, serves as a base point for a cost or design analysis, and it can often be quantitized in specific mathematical form. From this point, the engineer must apply judgment to take into account other important practical factors, such as return on investment or the fact that commercial equipment is often available in discrete intervals of size. [Pg.343]

D. Final recommended design with appropriate data... [Pg.456]

DHHS (U.S. Department of Healdi and Human Services, Centers for Disease Control). 1988. Final recommendations for protecting the healdi and safety against potential adverse effects of long-term exposure to low doses of agents GA, GB, Mustard (H, HD, T), and... [Pg.207]

The National Coimcil for Radiation Protection (NCRP) has identified a negligible individual risk level (NIRL) as a level of annual excess risk of health effects attributable to irradiation below which further effort to reduce radiation to the individual is unwarranted. The NCRP emphasized that this level should not be confused with an acceptable risk level, a level of significance or a standard. The NCRP recommended a level around half the natural background radiation level the final recommended NIRL level is 1 mrem this level is now called negligible individual dose (NID) level (Harley, 2001, 2008). [Pg.384]

Not all critical alarm reports describe the investigation, provide an assignable cause for the alarm, or describe the corrective actions are performed, conclusions and final recommendations. [FDA 483, 2001]... [Pg.286]


See other pages where Final Recommendations is mentioned: [Pg.996]    [Pg.1280]    [Pg.179]    [Pg.271]    [Pg.58]    [Pg.214]    [Pg.339]    [Pg.491]    [Pg.102]    [Pg.357]    [Pg.257]    [Pg.325]    [Pg.208]    [Pg.137]    [Pg.15]    [Pg.319]    [Pg.826]    [Pg.277]    [Pg.190]    [Pg.134]    [Pg.665]   


SEARCH



Final Remarks and Recommendations

Pressure drop final recommended

© 2024 chempedia.info