Feedback Derivative

The general expression for the disassembly reactivity feedback derived in Appendix Al, Eq. (A 1.23), is... [Pg.238]

Feedback derived from incident reports keeps system actors in the loop and encourages agent participation in safety improvement. Operators can see that their concerns are being followed up effectively. [Pg.383]

Some of the inherent advantages of the feedback control strategy are as follows regardless of the source or nature of the disturbance, the manipulated variable(s) adjusts to correct for the deviation from the setpoint when the deviation is detected the proper values of the manipulated variables are continually sought to balance the system by a trial-and-error approach no mathematical model of the process is required and the most often used feedback control algorithm (some form of proportional—integral—derivative control) is both robust and versatile. [Pg.60]

Classical Feedback Control. The majority of controllers ia a continuous process plant is of the linear feedback controller type. These controllers utilize one or more of three basic modes of control proportional (P), iategral (I), and derivative (D) action (1,2,6,7). In the days of pneumatic or electrical analogue controllers, these modes were implemented ia the controller by hardware devices. These controllers implemented all or parts of the foUowiag control algorithm ... [Pg.68]

Process-variable feedback for the controller is achieved by one of two methods. The process variable can (I) be measured and transmitted to the controller by using a separate measurement transmitter with a 0.2-I.0-bar (3-15-psi pneumatic output, or (2) be sensed directly by the controller, which contains the measurement sensor within its enclosure. Controllers with integral sensing elements are available that sense pressure, differential pressure, temperature, and level. Some controller designs have the set point adjustment knob in the controller, making set point adjustment a local and manual operation. Other types receive a set point from a remotely located pneumatic source, such as a manual air set regulator or another controller, to achieve set point adjustment. There are versions of the pneumatic controller that support the useful one-, two-, and three-mode combinations of proportional, integral, and derivative actions. Other options include auto/manual transfer stations, antireset windup circuitry, on/off control, and process-variable and set point indicators. [Pg.776]

In the foregoing treatments of pressure feedback, the simulation volume retains its cubic form, so changes consist of uniform contractions and expansions. The method is readily extended to the case of a simulation region in which the lengths and directions of the edges are allowed to vary independently. Parrinello and Rahman [31] and Nose and Klein [32] extended the Andersen method to the case of noncubic simulation cells and derived a new Lagrangian for the extended system. Though their equations of motion are... [Pg.61]

The quality of combustion can be measured with suitable instrumentation, on either a periodic or a continual basis. If continuous analysis is practiced then there may be feedback to continuously adjust the air/gas ratio and/or ratio and/or record the data derived. [Pg.276]

Since biosynthesis of IMP consumes glycine, glutamine, tetrahydrofolate derivatives, aspartate, and ATP, it is advantageous to regulate purine biosynthesis. The major determinant of the rate of de novo purine nucleotide biosynthesis is the concentration of PRPP, whose pool size depends on its rates of synthesis, utilization, and degradation. The rate of PRPP synthesis depends on the availabihty of ribose 5-phosphate and on the activity of PRPP synthase, an enzyme sensitive to feedback inhibition by AMP, ADP, GMP, and GDP. [Pg.294]

Instrumentation is also fitted to provide a continuous display of important variables such as temperature and pH, the power used hy the electric motor, airflow, dissolved oxygen and exhaust gas analysis. Manual or computer feedback control can be based either directly on the signals provided hy the prohes and sensors or on derived data calculated from those signals, such as the respiratory coefficient or the rate of change of pH. Mass spectronomical analysis of exhaust gases can provide valuable physiological information. [Pg.154]

Example 2.15. Derive the closed-loop transfer function C/R for the system with three overlapping negative feedback loops in Fig. E2.15(a). [Pg.40]

This configuration is also referred to as interacting PID, series PID, or rate-before-reset. To eliminate derivative kick, the derivative lead-lag element is implemented on the measured (controlled) variable in the feedback loop. [Pg.88]

There are other methods in pole-placement design. One of them is the Ackermann s formula. The derivation of Eq. (9-21) predicates that we have put (9-13) in the controllable canonical form. Ackermann s formula only requires that the system (9-13) be completely state controllable. If so, we can evaluate the state feedback gain as 1... [Pg.176]

When we have a really simple problem, we should not even need to use feedback (). Yes, we can derive the closed-loop transfer functions ourselves. For example, if we have a proportional controller with Gc = Kc, and a first order process, all we need are the following... [Pg.242]

Try a proportional controller with a second order process as derived in Example 5.2 in text. This is another simple problem that we do not really need feedback (). [Pg.242]

A control algorithm has been derived that has improved the dynamic decoupling of the two outputs MW and S while maintaining a minimum "cost of operation" at the steady state. This algorithm combines precompensation on the flow rate to the reactor with state variable feedback to improve the overall speed of response. Although based on the linearized model, the algorithm has been demonstrated to work well for the nonlinear reactor model. [Pg.198]

These cause dynamic issues to the switching power supply, and usually the only solution to that is to have enough bulk capacitance present on the 12V output rail. Luckily, since the main feedback loop is derived from the primary 5V/3.3V rails of the power supply, there is no minimum ESR requirement for the 12V rail output capacitance, and we can freely add several electrolytic capacitors in parallel. However, modern core processors can place very fast transient load demands on the primary regulated rail, too, and for that we need a whole bunch of ceramic capacitors sitting right at the point of load. In that case we must ensure the converter is designed to accept ceramic loads. Otherwise it will break up into oscillations. [Pg.190]

The phorbol esters are useful for studying the function of PKC since they mimic the stimulatory effects of DAG on the enzyme. These tumor-promoting plant products and their synthetic derivatives are able to penetrate intact cells. Many inferences regarding the intracellular actions of PKC are based on results of studies on whole-cell preparations with the phorbol esters. These substances, like DAG, may produce feedback inhibition of signal transduction at a number of metabolic levels. Results of experiments using phorbol esters in whole cells are thus often complex and must be interpreted cautiously. Notwithstanding this consideration, based upon... [Pg.357]


See other pages where Feedback Derivative is mentioned: [Pg.79]    [Pg.11]    [Pg.79]    [Pg.11]    [Pg.175]    [Pg.175]    [Pg.222]    [Pg.71]    [Pg.718]    [Pg.727]    [Pg.783]    [Pg.63]    [Pg.92]    [Pg.430]    [Pg.158]    [Pg.446]    [Pg.487]    [Pg.157]    [Pg.258]    [Pg.174]    [Pg.310]    [Pg.240]    [Pg.360]    [Pg.431]    [Pg.19]    [Pg.73]    [Pg.105]    [Pg.186]    [Pg.191]    [Pg.225]    [Pg.99]    [Pg.448]    [Pg.112]    [Pg.171]    [Pg.363]   
See also in sourсe #XX -- [ Pg.84 , Pg.88 ]