Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Experiment files

Instruments are controlled by information contained 1n the experimental setup file. For each type of instrument (shear history simulator, rotational viscometer, reciprocating capillary viscometer), the hardware 1s controlled so that the parameters of shear rate, temperature and time comply with the desired test conditions. This involves controlling devices such as pumps, bath heaters, valves and variable-speed motors. The setup and control parameters are recorded in the experiment file along with the resulting measured data. If necessary, the experiment can easily be repeated. [Pg.109]

Previous Human Experience You should provide previous human experience in a separate PDF file that is reserved for summary information. You should include a TOC in the previous human experience file. You should name the file XXXX prevhumexptoc.pdf You should bookmark and hypertext link the TOC for this file. If you are providing study reports, you should provide them as described in the appropriate marketing guidance document. [Pg.113]

The MassChrom software requires three files to set up and acquire data the Method, State, and Experiment files. The method and experiment files are used to set up and acquire mass spectrometer data and the experiment and state files used to monitor the performance of the mass spectrometer itself. [Pg.500]

In contrast, there are just two such files used within the Analyst data acquisition method (DAM) and instrument file format (INS) files. The mapping of the MassChrom and Analyst files is not one to one parameters in the experiment file are split between the INS and DAM files on the Analyst application. [Pg.500]

ExptFile Converter — Experiment file conversion program that combines a Macintosh state file and a Macintosh experiment file and generates an Analyst data acquisition method file (DAM). [Pg.503]

With the term w representing the effective migration or drift velocity. (Note wA/q is often denoted as numerical value of w is selected on the basis of experience with a particular dust, a particular set of operating conditions, and a particular design. Precipitator manufacturers usually have a specific experience file from which the precipitation rate parameter can be selected for various applications and conditions. Average values of precipitation rate parameters for various applications, and the range of values that might be expected, are presented below. [Pg.306]

The last information service to be specifically mentioned is the engineer s personal experience file. It should be applied last, but it is most important. Attempts have been made to publish certain standardized specifications for mechanical equipment, but so far this has not been done in a general fashion for a large number of types of chemical equipment thus it is still the fundamental job of the engineer to keep his own check list. This should contain details of the specifications and, in particular, should have underscored the obvious details most frequently omitted. [Pg.39]

The fir.-fit line of the file (see Figure 2-110) - the HEADER record - hold.s the moleculc. s classification string (columns 11-50), the deposition date (the date when the data were received by the PDB) in columns 51-59, and the PDB (Dcode for the molecule, which is unique within the Protein Data Bank, in columns 63-66. The second line - the TITLE record - contains the title of the experiment or the analysis that is represented in the entry. The subsequent records contain a more detailed description of the macromolecular content of the entiy (COMPND), the biological and/or chemical source ofeach biological molecule in the entiy (SOURCE), a set ofkeywords relevant to the entiy (KEYWDS). information about the experiment (EXPDTA), a list of people responsible for the contents of this entiy (.AUTHOR), a history of modifications made to this entiy since its release (REVDAT), and finally the primaiy literature citation that describes the experiment which resulted in the deposited dataset ()RNL). [Pg.115]

As an interesting variation on this experiment, one can try reading in the experimental data from an external file. The student should do some outside... [Pg.330]

Gaussian is designed to execute as a batch job. It can readily be used with common batch-queueing systems. The program may be purchased as source code or executables and comes with hundreds of sample input and output files. These may be employed as examples of how to construct inputs. They may also be employed to verify that a compilation from source code was successful. In our experience, such verification is essential. [Pg.337]

Several of the reactor physics parameters are both measurable and calculable from more fundamental properties such as the energy-dependent neutron cross sections and atom number densities. An extensive database. Evaluated Nuclear Data Files (ENDF), has been maintained over several decades. There is an interplay between theory and experiment to guide design of a reactor, as in other engineering systems. [Pg.212]

QRA practitioners can use to satisfy some QRA objectives. Also, the American Institute of Chemical Engineers (AIChE) has sponsored a project to expand and improve the quality of component failure data for chemical industry use. And many process facilities have considerable equipment operating experience in maintenance files, operating logs, and the minds of operators and maintenance personnel. These data can be collected and combined with industrywide data to help achieve reasonable QRA objectives. However, care must be exercised to select data most representative of your specific system from the wide range available from various sources. Even data from your own plant may have to be modified (sometimes by a factor of 10 or more) to reflect your plant s current operating environment and maintenance practices. [Pg.10]

Signatures should be obtained and retained on file. Although an unlikely occurrence, you may rarely find a worker who refuses to sign a document. This signature refusal experience can be traumatic, especially for the inexperienced manager. We recommend that before you get upset, you try both adjourning to a neutral corner and ironing out difficulties. [Pg.75]

Pharmacodynamic tolerance to the psychomotor effects of benzodiazepines has been demonstrated after single or multiple doses (File 1985 Greenblatt and Shader 1978 Rosenberg and Chiu 1985). Pharmacodynamic tolerance to the anxiolytic effect (over a 6-month period) has not been demonstrated (Rickels et al. 1983), and clinical experience supports the view that many patients with anxiety disorders require long-term therapy with benzodiazepines or alternative antianxiety agents. An important clinical consequence of tolerance to sedative effects is observed in benzodiazepine overdoses, when patients may initially be... [Pg.123]

Figure 3.7. Schematic depiction of the relation between experiment and simulation. The first step is to define the experimental conditions (concentrations, molecular species, etc.), which then form the basis either for the experiment or for simulation. Real data are manually or automatically transferred from the instruments to the data file for further processing. Simulated values are formatted to appear indistinguishable from genuine data. Figure 3.7. Schematic depiction of the relation between experiment and simulation. The first step is to define the experimental conditions (concentrations, molecular species, etc.), which then form the basis either for the experiment or for simulation. Real data are manually or automatically transferred from the instruments to the data file for further processing. Simulated values are formatted to appear indistinguishable from genuine data.
The above data base is systematically modified to force the program to its limits. For example, the number of measurements is multiplied by entering each datum several times instead of only once, etc. That this step is necessary is shown by the authors occasional experience that commercial programs as simple as a sorting routine would only work with the supplied demonstration data file. [Pg.173]


See other pages where Experiment files is mentioned: [Pg.307]    [Pg.308]    [Pg.660]    [Pg.307]    [Pg.308]    [Pg.660]    [Pg.50]    [Pg.113]    [Pg.123]    [Pg.329]    [Pg.3]    [Pg.118]    [Pg.154]    [Pg.329]    [Pg.234]    [Pg.399]    [Pg.402]    [Pg.60]    [Pg.134]    [Pg.263]    [Pg.70]    [Pg.265]    [Pg.384]    [Pg.166]    [Pg.90]    [Pg.4]    [Pg.3]    [Pg.365]    [Pg.62]    [Pg.229]    [Pg.538]    [Pg.930]    [Pg.53]    [Pg.132]    [Pg.28]    [Pg.43]    [Pg.240]   