This method for obtaining components for receptor models has several advantages relative to other methods. First, the component will be determined at the receptor sites, after any condensation, coagulation or fallout during transit has occurred. Second, It may include fugitive emissions from the source as well as ducted emissions. Third, the measurements are made at the same time and with the same device as the ambient sampling. Fourth, the measurements are made on emissions from specific sources In the local area, not just on the same class of source somewhere else. Fifth, the measurements do not require cooperation of the source operators or Intrusion upon their property. [Pg.71]

Existing data on characteristics of particles from various types of sources are inadequate for general use, though they have been used in specific studies with some success. Most of the source tests have been made for purposes other than receptor modeling and complete chemical and microscopical analyses have not been performed. Source operating parameters which might affect the aerosol properties of emissions have not been identified nor measured in ambient sampling and no provision is made for likely transformations of the source material when it comes into equilibrium under ambient conditions. [Pg.100]

Thus the concentration of each chemical element at a receptor site becomes a linear combination of the contributions of each source to the particulate matter at that site. Given the chemical composition of the ambient sample c, and the source emission signature fly,... [Pg.1138]

Chemical mass balances have been used to calculate the source contributions to rainwater chemistry(3,4,17). The source strength model as described by Miller et al.(28) was developed to determine the contribution of different aerosol sources to the ambient particulate aerosol from the chemical composition of the source emissions and the ambient aerosol. The percentage of the ith element in the ambient sample, p, was given by... [Pg.116]

To examine a sample by inductively coupled plasma mass spectrometry (ICP/MS) or inductively coupled plasma atomic-emission spectroscopy (ICP/AES) the sample must be transported into the flame of a plasma torch. Once in the flame, sample molecules are literally ripped apart to form ions of their constituent elements. These fragmentation and ionization processes are described in Chapters 6 and 14. To introduce samples into the center of the (plasma) flame, they must be transported there as gases, as finely dispersed droplets of a solution, or as fine particulate matter. The various methods of sample introduction are described here in three parts — A, B, and C Chapters 15, 16, and 17 — to cover gases, solutions (liquids), and solids. Some types of sample inlets are multipurpose and can be used with gases and liquids or with liquids and solids, but others have been designed specifically for only one kind of analysis. However, the principles governing the operation of inlet systems fall into a small number of categories. This chapter discusses specifically substances that are normally liquids at ambient temperatures. This sort of inlet is the commonest in analytical work. [Pg.103]

Emission spectroscopy is the analysis, usually for elemental composition, of the spectmm emitted by a sample at high temperature, or that has been excited by an electric spark or laser. The direct detection and spectroscopic analysis of ambient thermal emission, usually ia the iafrared or microwave regioas, without active excitatioa, is oftea termed radiometry. la emission methods the sigaal iateasity is directiy proportioaal to the amouat of analyte present. [Pg.310]

Radiometry. Radiometry is the measurement of radiant electromagnetic energy (17,18,134), considered herein to be the direct detection and spectroscopic analysis of ambient thermal emission, as distinguished from techniques in which the sample is actively probed. At any temperature above absolute zero, some molecules are in thermally populated excited levels, and transitions from these to the ground state radiate energy at characteristic frequencies. Erom Wien s displacement law, T = 2898 //m-K, the emission maximum at 300 K is near 10 fim in the mid-ir. This radiation occurs at just the energies of molecular rovibrational transitions, so thermal emission carries much the same information as an ir absorption spectmm. Detection of the emissions of remote thermal sources is the ultimate passive and noninvasive technique, requiring not even an optical probe of the sampled volume. [Pg.315]

When the spectral characteristics of the source itself are of primary interest, dispersive or ftir spectrometers are readily adapted to emission spectroscopy. Commercial instmments usually have a port that can accept an input beam without disturbing the usual source optics. Infrared emission spectroscopy at ambient or only moderately elevated temperatures has the advantage that no sample preparation is necessary. It is particularly appHcable to opaque and highly scattering samples, anodized and painted surfaces, polymer films, and atmospheric species (135). The interferometric... [Pg.315]

In the United States, the largest concentration of atmospheric vanadium occurs over Eastern seaboard cities where residual fuels of high vanadium content from Venezuela are burned ia utility boilers. Coal ash ia the atmosphere also coataias vanadium (36). Ambient air samples from New York and Boston contain as much as 600—1300 ng V/m, whereas air samples from Los Angeles and Honolulu contained 1—12 ng V/m. Adverse pubHc health effects attributable to vanadium ia the ambieat air have aot beea deteroiiaed. lacreased emphasis by iadustry oa controlling all plant emissions may have resulted ia more internal reclamation and recycle of vanadium catalysts. An apparent drop ia consumption of vanadium chemicals ia the United States since 1974 may be attributed, in part, to such reclamation activities. [Pg.393]

Pollutant concentration maps may be constructed as shown in Fig. 15-5 (14). In this example, elevated levels of ambient particulate matter are associated with population centers. For a given geographic area, isopleths, lines showing equal concentrations of a pollutant, are drawn on a map. Regions of high concentration are quickly identified. Further action may be taken to determine the cause, such as review of emission inventories of additional sampling. [Pg.227]

The flame ionization detector is capable of measuring only gaseous hydrocarbons, in other words, hydrocarbons that have a low boiling point. Emission gases can, however, also contain hydrocarbons in liquid form at ambient temperature and pressure. Therefore, analyzers based on flame ionization detection are generally equipped with heating elements to keep rhe sampling line and the detector at about 200 °C. [Pg.1298]

At the time of writing, in all papers published on adsorption studies on oxides surfaces, spectra have been reported of samples held at the ambient temperature of the sample compartment. It is obvious that when dealing with very volatile adsorbates, low temperature sample cells may be required to increase adsorption and also to prevent rapid desorption of the adsorbed species. In some instances, it is also desirable to record the spectra of species held at elevated temperatures for better correlation with industrial catalytic systems. It should be noted that there are only a few infrared spectra reported in the literature for high temperature studies of catalytic reactions. Sample emission at elevated temperature is a significant experimental complication in investigations of this type. [Pg.319]

The role of meteorological and climatic factors and their variability. Ambient air quality (e.g., oxidant concentrations) and deposition that can affect the emissions to indicator relationship. Sampling frequency is also an important attribute of a monitoring program that strongly influences the ability to detect trends. [Pg.18]

Another study employed a similar RP-HPLC method for the determination of trails- and d.v-rcsvcratrol, catechin, epicatechin, quercetin and rutin in wines and musts. Wine samples were filtered and diluted when necessary and used for analysis without any other pretreatment. Separation was performed in an ODS column (150 X 4 mm i.d. paricle size 5 71m) at ambient temperature. The gradient began with ACN-5 per cent aqueous acetic acid (9 91, v/v) for 0-10 min to 25 75 in 1 min hold for 11 min to 70 30 in 1 min, hold for 5 min. The flow rate was 1 ml/min. Analytes were detected by DAD. Fluorescence detection used 280/315 nm (excitation/emission) for catechin and epicatechin 314/370 nm for fims-resveratrol and 260/370 nm for d.v-rcsvcratrol. Chromatograms of a red wine sample obtained at different... [Pg.221]

To obtain multiple sets of experimental dispersion data, in each experiment 50 samples of tracer-polluted ambient air downwind in the plume of the propane emission source are taken by 10 sample units, distributed in the field, see fig. 3, Each unit carries five glass cylinders, filled with... [Pg.111]


See other pages where Emission ambient sampling is mentioned: [Pg.384]    [Pg.384]    [Pg.139]    [Pg.928]    [Pg.180]    [Pg.290]    [Pg.98]    [Pg.499]    [Pg.224]    [Pg.308]    [Pg.128]    [Pg.40]    [Pg.121]    [Pg.384]    [Pg.384]    [Pg.384]    [Pg.384]    [Pg.38]    [Pg.246]    [Pg.97]    [Pg.384]    [Pg.421]    [Pg.196]    [Pg.395]    [Pg.374]    [Pg.58]    [Pg.92]    [Pg.934]    [Pg.408]    [Pg.36]    [Pg.196]    [Pg.29]    [Pg.1130]    [Pg.148]   