Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Resolution electrophoresis

Disc Electrophoresis. Resolution in zone electrophoresis depends critically on getting sample components to migrate in a focused band, thus some techniques ate employed to concentrate the sample as it migrates through the gel. The most common technique is referred to as discontinuous pH or disc electrophoresis. Disc electrophoresis employs a two-gel system, where the properties of the two gels are different. [Pg.180]

S Fanali, E Camera. Use of methylamino-/3-cyclodextrin in capillary electrophoresis. Resolution of acidic and basic enantiomers. Chromatographia 43 247-253, 1996. [Pg.111]

Capillary Electrophoresis. Capillary electrophoresis (ce) or capillary 2one electrophoresis (c2e), a relatively recent addition to the arsenal of analytical techniques (20,21), has also been demonstrated as a powerful chiral separation method. Its high resolution capabiUty and lower sample loading relative to hplc makes it ideal for the separation of minute amounts of components in complex biological mixtures (22,23). [Pg.61]

Biomolecule Separations. Advances in chemical separation techniques such as capillary zone electrophoresis (cze) and sedimentation field flow fractionation (sfff) allow for the isolation of nanogram quantities of amino acids and proteins, as weU as the characterization of large biomolecules (63—68) (see Biopolymers, analytical techniques). The two aforementioned techniques, as weU as chromatography and centrifugation, ate all based upon the differential migration of materials. Trends in the area of separations are toward the manipulation of smaller sample volumes, more rapid purification and analysis of materials, higher resolution of complex mixtures, milder conditions, and higher recovery (69). [Pg.396]

Capillary Electrophoresis. Capillary electrophoresis (ce) is an analytical technique that can achieve rapid high resolution separation of water-soluble components present in small sample volumes. The separations are generally based on the principle of electrically driven ions in solution. Selectivity can be varied by the alteration of pH, ionic strength, electrolyte composition, or by incorporation of additives. Typical examples of additives include organic solvents, surfactants (qv), and complexation agents (see Chelating agents). [Pg.246]

The heating effect is the limiting factor for all electrophoretic separations. When heat is dissipated rapidly, as in capillary electrophoresis, rapid, high resolution separations are possible. For electrophoretic separations the higher the separating driving force, ie, the electric field strength, the better the resolution. This means that if a way to separate faster can be found, it should also be a more effective separation. This is the opposite of most other separation techniques. [Pg.179]

Most electrophoretic methods have been tried in a free-flow format, including isoelectric focusing, native zone electrophoresis, and isotachophoresis. Most free-flow electrophoresis equipment has very low (ca 1 g/(L-h)) capacity, and resolution is reduced by heating and electroosmotic considerations. [Pg.183]

Two-Dimensional Electrophoresis. Two-dimensional (2D) electrophoresis is unique, offering an analytical method that is both reproducible and sensitive. It is referred to as 2D because it employs two different methods of electrophoresis, in two different dimensions, to produce one result. Each method separates the sample compounds based on different properties of each compound. The combination of the two methods gives better resolution of the compounds in the sample than could be achieved with either method alone. For example, each method alone may separate up to 100 components of a sample, whereas together they may separate up to 10,000 components. [Pg.184]

The final purification steps are responsible for the removal of the last traces of impurities. The volume reduction in the earlier stages of the separation train are necessarv to ensure that these high-resolution operations are not overloaded. Generally, chromatograjmy is used in these final stages. Electrophoresis can also be used, but since it is rarely found in process-scale operations, it is not addressed here. The final product preparation may require removal of solvent and drying, or lyophihzation, of the product. [Pg.2061]

Isolation procedures for many biochemicals are based on chromatography. Practically any substance can be selected from a crude mixture and eluted at relatively high purity from a chromatographic column with the right combination of adsorbent, conditions, and eluant. For bench scale or for a small pilot plant, such chromatography has rendered alternate procedures such as electrophoresis nearly obsolete. Unfortunately, as size increases, dispersion in the column ruins resolution. To produce small amounts or up to tens of kilograms per year, chromatography is an excellent choice. When the scale-up problem is solved, these procedures should displace some of the conventional steps in the chemical process industries. [Pg.2144]

P. H. O Eaixell, High resolution two-dimensional electrophoresis of proteins , 7. Biol. Chem. 250 4007 (1975). [Pg.15]

This chapter will first cover the nature of electrophoretic separations, especially those concerning capillary electrophoresis. Comprehensive multidimensional separations will then be defined, specifically in terms of orthogonality and resolution. The history of planar and non-comprehensive electrodriven separations will then be discussed. True comprehensive multidimensional separations involving chromatography and capillary electrophoresis will be described next. Finally, the future directions of these multidimensional techniques will be outlined. [Pg.197]

Yamamoto et al. also coupled gel permeation HPLC and CE in an on-line fashion in 1990, where capillary isotachophoresis was again used in the second dimension. This technique was also not comprehensive due to the loss of resolution between the techniques. It was also not particularly fast, with a 23 min CE cycle, which was repeated 90 times throughout the HPLC run (14). Volume incompatibility between HPLC and CE was one problem not addressed in this study, in which a large HPLC column was coupled to an electrophoresis capillary. [Pg.203]

E. M. Benson, A. J. Tomlinson and S. Nayloi, Time course analysis of a microsomal incubation of a therapeutic dmg using preconcenti ation capillary electrophoresis (Pc-CE) , 7. High Resolut. Chromatogr. 17 671-673 (1994). [Pg.301]

Recently, the separation of some milligram quantities of terbutaline by classical gel electrophoresis has been reported [194]. A sulfated cyclodextrin impregnated on the agarose gel was used as a chiral selector and the complete resolution was achieved in 5 h. Analogously, small amounts of enantiomers can be isolated using thin-layer... [Pg.16]

Enantioresolution in capillary electrophoresis (CE) is typically achieved with the help of chiral additives dissolved in the background electrolyte. A number of low as well as high molecular weight compounds such as proteins, antibiotics, crown ethers, and cyclodextrins have already been tested and optimized. Since the mechanism of retention and resolution remains ambiguous, the selection of an additive best suited for the specific separation relies on the one-at-a-time testing of each individual compound, a tedious process at best. Obviously, the use of a mixed library of chiral additives combined with an efficient deconvolution strategy has the potential to accelerate this selection. [Pg.62]

Advances in experimental techniques, including pulsed-field gradient NMR, and theoretical methods, including volume averaging, macrotransport, and variational methods, that may lead to the resolution of a number of the fundamental issues in gel electrophoresis and to improvements in the practical application of electrotransport in polymeric media... [Pg.528]


See other pages where Resolution electrophoresis is mentioned: [Pg.271]    [Pg.21]    [Pg.638]    [Pg.341]    [Pg.271]    [Pg.21]    [Pg.638]    [Pg.341]    [Pg.609]    [Pg.397]    [Pg.404]    [Pg.246]    [Pg.251]    [Pg.178]    [Pg.179]    [Pg.180]    [Pg.181]    [Pg.181]    [Pg.104]    [Pg.111]    [Pg.536]    [Pg.196]    [Pg.266]    [Pg.299]    [Pg.13]    [Pg.94]    [Pg.198]    [Pg.213]    [Pg.1028]    [Pg.128]    [Pg.527]    [Pg.533]    [Pg.542]    [Pg.603]   
See also in sourсe #XX -- [ Pg.310 , Pg.311 , Pg.312 , Pg.313 , Pg.314 ]

See also in sourсe #XX -- [ Pg.55 ]




SEARCH



Capillary electrophoresis chiral resolution

Capillary electrophoresis resolution mechanisms

Capillary electrophoresis resolution separation technique

High-resolution electrophoresis

High-resolution polyacrylamide electrophoresis

High-resolution polyacrylamide gel electrophoresis

Resolution capillary electrophoresis

Resolution capillary zone electrophoresis

Resolution in capillary electrophoresis

© 2024 chempedia.info