The experimental setup included a three-electrode electrochemical cell with a liquid contact membrane electrode in which the internal Ag/AgCl electrode acted as a working electrode connected to a potentiostat/galvanostat. The instrument was capable of switching rapidly between potentiostatic and galvanostatic modes [51]. [Pg.113]

A CH Instruments 800B electrochemical analyzer (Austin, TX) was used for all electrochemical measurements and electrode preparation. Glassy carbon (GC) electrodes (3 mm diameter, geometrical area 0.07 cm2) were purchased from CH Instruments (Austin, TX) and polished with polishing alumina solution (BAS, West Lafayette, IN). All electrochemical measurements were conducted in a conventional three-electrode cell using Ag/AgCl (3M KC1) (CH Instruments,... [Pg.256]

The electrochemical cell is coupled to a three-electrode potentiostatted form of instrumentation. If a two-electrode (working and reference) system were to be used, the current would have to flow through the reference electrode, thus risking instability in the reference potential. Furthermore, in a two-electrode system, the IR drop could be substantial. In contrast, in the three-electrode potentiostatted system, the current is forced to flow through the counter electrode, thereby avoiding problems with the reference electrode. Additionally, much of the IR drop is compensated by the potentiostat circuitry (Macdonald, 1977), which drives the potential between the working and counter electrode to a value which compensates the majority of this potential loss. However, the use of a potentiostat does not remove all of the IRu drop, since uncompensated resistance remains due to solution resistance between the tip of the reference and working electrodes, and... [Pg.13]

The electrochemical sensing system was set up in a cylindrical quartz cell equipped with a standard three-electrode configuration and controlled by an electrochemical workstation (CHI 660C, CH Instruments Co., Ltd. USA). Both bare Ti02/Ti and functional GOD-Ti02/Ti nanotube array were used as the working electrodes with an effective reaction area of 2.0 cm2. A standard Hg/Hg2Cl2 saturated calomel electrode (SCE) was used as a reference electrode and Pt foil was used as a counter electrode. Standard calibration curve (responsive current... [Pg.243]

From a practical viewpoint, feedback measurements are easier to implement than TG/SC measurements in terms of both the electrochemical and positioning instrumentation required. In the feedback mode, it is often unnecessary to bias the substrate externally, allowing the use of a simple two-or three-electrode arrangement in which the tip UME is the sole working electrode. The rationale for making feedback measurements under these conditions was discussed in Chapter 1 and is considered in detail elsewhere (9). In brief, and with reference to the example in Figure 1, an externally unbiased substrate electrode will be bathed predominantly in A, the only electroactive species initially present in solution, provided that the substrate is sufficiently large and the A/B couple is sufficiently reversible. Under these... [Pg.242]

Instrumentation. A suitable microelectrode [119] or nanoelectrode [127] is attached to a piezo-driven micropositioner. It is connected as the working electrode with a potentiostat. A counter electrode and a reference electrode are wired in a three-electrode arrangement. Investigations with conducting substrates require the use of a bipotentiostat. The surface to be investigated is immersed into the electrochemical cell together with the other electrodes. The position of the microelectrode and the flowing current are controlled and monitored by a computer equipped with... [Pg.266]

As an example of a practical situation where the instrument has been used, the study of an electrically conductive polymer, poly(3-octylthiophene), is representative. This polymer is electrochemically polymerized on a Pt-disc, which then is used as a working electrode in a conventional three-electrode electrochemical cell. In this example glassy-carbon was used as an auxiliary electrode, while the reference electrode was a Ag/AgCl (3M KCl). The supporting electrolyte was 0.1 M LiBF4 in propylene carbonate. [Pg.27]

Cyclic voltammetric data, even when using a three-electrode potentiostat form of instrumentation, can be affected by the presence of uncompensated resistance in the solution phase between the reference and the working electrode and of the working electrode itself, and by the capacity of the working electrode. A simple electrochemical cell may be described by an equivalent circuit, in which electronic... [Pg.71]

The electrochemical cell would need quartz windows. A typical three-electrode system, with WE, CE, and reference electrode, is used. Eor IR work, the source and spectrometer would have to be suitable and the windows of the cell would have to be IR transparent, for example, CaFj. Suitable materials have been discussed for both techniques in Chapters 4 and 5. Commercial systems are available from BioLogic Science Instruments, Claix, Erance (www.bio-Iogic.info), and from ZAHNER-Elektrik GmbH Co., KG, Kronach, Germany (www.zahner.de). Their websites contain pictures and detailed instrument descriptions as well as a number of application notes and technical notes. [Pg.1123]

Instruments suitable for voltammetry and am-perometry consist of three basic components a wave-form generator, some form of potential control, and an electrochemical cell. Modem electro-analytical systems employ a three-electrode arrangement for the electrochemical cell. A device called a poleiuiosiat is used to maintain a programmed or fixed potential difference between the two current-carrying electrodes (the working electrode and the auxiliary electrode) relative to a third electrode (reference electrode), the function of which is to provide a fixed potential reference in the cell [64], [65]. [Pg.979]

In addition, ECL experiments can also be carried out using a commercial fluorescence spectrometer coupled with an electrochemical instrument with the excitation function of the fluorimeter disabled. For example, one can have the three electrodes fitted into a standard fluorescence cuvette so that the entire cell system fits into the sample compartment of the spectrometer. The electrodes should be arranged so that the working electrode faces the detection window of the emission monochromator. ECL intensity can be measured either at... [Pg.566]

Unlike the situation at a solid/electrolyte interface where a three-electrode system is used, four- and two-electrode systems have been widely employed for large and small liquid/ liquid interfaces. Most of the four-electrode potentiostats are homemade and only a few instruments with such functions have been commercialized (98). This is probably one of the reasons why this field has not been very popular since most electrochemical laboratories are equipped with a three-electrode potentiostat. In 1998, Anson et al. reported that charge transfer reactions at a liquid/liquid interface could also be studied by a three-electrode system with a thin-layer cell (99,1(X)). Later, Scholz et al. reported a three-phase junction setup (101, 102). Shao et al. supported a small droplet of aqueous solution (pL) containing a certain concentration ratio of redox couples on a Pt surface and demonstrated that charge transfer could be studied by a three-electrode setup (103). Girault et al. extended this to a supported small droplet of aqueous (organic) phase on the surface of... [Pg.801]

All experiments in this paper were performed in an UHV surface analysis instrument equipped with a Phi model 3017 Auger electron spectroscopy subsystem and Phi model 15-120 low energy electron diffraction EED) optics. The instrument was also equipped with an electrochemical antechamber used to perform the etching experiments (1,26,27). A standard, in-house built, three electrode... [Pg.117]


See other pages where Instrumentation, three-electrode electrochemical is mentioned: [Pg.312]    [Pg.252]    [Pg.98]    [Pg.26]    [Pg.74]    [Pg.99]    [Pg.143]    [Pg.1271]    [Pg.199]    [Pg.90]    [Pg.90]    [Pg.58]    [Pg.57]    [Pg.25]    [Pg.474]    [Pg.302]    [Pg.632]    [Pg.654]    [Pg.194]    [Pg.859]    [Pg.3]    [Pg.57]    [Pg.171]    [Pg.3]    [Pg.279]    [Pg.285]    [Pg.203]    [Pg.224]    [Pg.1365]    [Pg.901]    [Pg.33]    [Pg.65]    [Pg.1197]    [Pg.196]    [Pg.830]   
See also in sourсe #XX -- [ Pg.58 ]




SEARCH



Electrochemical instrument

Electrochemical instrumentation

Electrochemical three-electrode

Electrodes electrochemical

Instrumentation three-electrode

Three-electrode

© 2024 chempedia.info