A much better way would be to use phase contrast, rather than attenuation contrast, since the phase change, due to changes in index of refraction, can be up to 1000 times larger than the change in amplitude. However, phase contrast techniques require the disposal of monochromatic X-ray sources, such as synchrotrons, combined with special optics, such as double crystal monochromatics and interferometers [2]. Recently [3] it has been shown that one can also obtain phase contrast by using a polychromatic X-ray source provided the source size and detector resolution are small enough to maintain sufficient spatial coherence. [Pg.573]

Fig. 3. (a) Flame ionization detector (fid) response to an extract of commercially processed Valencia orange juice, (b) Gas chromatography—olfactometry (geo) chromatogram of the same extract. The abscissa in both chromatograms is a normal paraffin retention index scale ranging between hexane and octadecane (Kovats index). Dilution value in the geo is the -fold that the extract had to be diluted until odor was no longer detectable at each index. [Pg.6]

Hplc techniques are used to routinely separate and quantify less volatile compounds. The hplc columns used to affect this separation are selected based on the constituents of interest. They are typically reverse phase or anion exchange in nature. The constituents routinely assayed in this type of analysis are those high in molecular weight or low in volatility. Specific compounds of interest include wood sugars, vanillin, and tannin complexes. The most common types of hplc detectors employed in the analysis of distilled spirits are the refractive index detector and the ultraviolet detector. Additionally, the recent introduction of the photodiode array detector is making a significant impact in the analysis of distilled spirits. [Pg.89]

Chromatographic conditions elution with 50 50 methanol/water solvent at the rate of 1.5 ml,/min through a DuPont Zorbax ODS column using a Waters R-401 Refractive Index Detector. [Pg.147]

Another classification of detector is the bulk-property detector, one that measures a change in some overall property of the system of mobile phase plus sample. The most commonly used bulk-property detector is the refractive-index (RI) detector. The RI detector, the closest thing to a universal detector in lc, monitors the difference between the refractive index of the effluent from the column and pure solvent. These detectors are not very good for detection of materials at low concentrations. Moreover, they are sensitive to fluctuations in temperature. [Pg.110]

Select the detector. To acquire molecular weight distribution data, use a general detector such as a refractive index detector. To acquire structural or compositional information, employ a more selective detector such as an ultraviolet (UV) or infrared (IR) detector. Viscometric and light-scattering detectors facilitate more accurate molecular weight measurement when appropriate standards are not available. [Pg.78]

Degassed and preswelled Bio-Gel P-6 and Sephacryl S-200 were packed in self-made glass columns (70 X 1.5 cm 140 X 1.5 cm) and equilibrated for 20 hr with H20(dest.) -t- 0.002% NaN3 to prevent microbial growth. The mass of eluted fractions was detected with a differential refractive index detector (Waters 403 RI, sensitivity 8). [Pg.486]

FIGURE 16.23 Inulln isolated from small (—). medium ( ) and large (A) tubers separated on P-6 (140 X 1.5 cm) flow rate 0.33 ml/min eluenf. H20(dest) + 0.002% NaNa mass detection Waters 403 R differential refractive index detector, sensitivity 8X applied sample solution volume I ml of a 20-mg/ml aqueous inulin solution. [Pg.487]

A more difficult criterion to meet with flow markers is that the polymer samples not contain interferents that coelute with or very near the flow marker and either affect its retention time or the ability of the analyst to reproducibly identify the retention time of the peak. Water is a ubiquitous problem in nonaqueous GPC and, when using a refractive index detector, it can cause a variable magnitude, negative area peak that may coelute with certain choices of totally permeated flow markers. This variable area negative peak may alter the apparent position of the flow marker when the flow rate has actually been invariant, thereby causing the user to falsely adjust data to compensate for the flow error. Similar problems can occur with the elution of positive peaks that are not exactly identical in elution to the totally permeated flow marker. Species that often contribute to these problems are residual monomer, reactants, surfactants, by-products, or buffers from the synthesis of the polymer. [Pg.549]

These combined HDF and GPC separations require the use of detectors such as static light scattering or viscometers to help sort out the convoluted elution profiles seen in those type of experiments. It should also be remembered in these situations that the typical refractive index or ultraviolet detector responses may not be representative of the actual mass fraction of insolubles eluting from the column because of the significant light scattering that can occur with those large particles in the detector cell. [Pg.553]

For acrylate polymers with higher levels of carboxylic acids, THF can be modified by the addition of acids such as acetic, phosphoric, or trifluoroacetic. Levels as high as 10% acetic acid are considered acceptable by most manufacturers for their styrene/DVB columns. If such a modified mobile phase is used, it may need to be premixed rather than generated using a dynamic mixing HPLC pump because on-line mixing often leads to much noisier baselines, particularly when using a refractive index detector. [Pg.553]

Synthetic, nonionic polymers generally elute with little or no adsorption on TSK-PW columns. Characterization of these polymers has been demonstrated successfully using four types of on-line detectors. These include differential refractive index (DRI), differential viscometry (DV), FALLS, and MALLS detection (4-8). Absolute molecular weight, root mean square (RMS) radius of gyration, conformational coefficients, and intrinsic viscosity distributions have... [Pg.562]

Detectors Model 410 differential refractive index (Waters Corporation) Model 100 differential viscometer (Viscotek Corporation) Dawn-F multiangle laser light-scattering photometer (Wyatt Technology)... [Pg.562]

Figure 14.17 Schematic diagram of the on-line coupled LC-GC system VI, valve foi switcliing the LC column outlet to the GC injector V2, valve for switching the LC column to back-flush mode V3, LC injection valve RI, refractive index monitor detector UV, ulti avio-let monitor detector FID, flame-ionization detector. Figure 14.17 Schematic diagram of the on-line coupled LC-GC system VI, valve foi switcliing the LC column outlet to the GC injector V2, valve for switching the LC column to back-flush mode V3, LC injection valve RI, refractive index monitor detector UV, ulti avio-let monitor detector FID, flame-ionization detector.
Refractive index detectors. These bulk property detectors are based on the change of refractive index of the eluant from the column with respect to pure mobile phase. Although they are widely used, the refractive index detectors suffer from several disadvantages — lack of high sensitivity, lack of suitability for gradient elution, and the need for strict temperature control ( + 0.001 °C) to operate at their highest sensitivity. A pulseless pump, or a reciprocating pump equipped with a pulse dampener, must also be employed. The effect of these limitations may to some extent be overcome by the use of differential systems in which the column eluant is compared with a reference flow of pure mobile phase. The two chief types of RI detector are as follows. [Pg.225]


See other pages where Detectors 582 INDEX is mentioned: [Pg.585]    [Pg.163]    [Pg.261]    [Pg.692]    [Pg.9]    [Pg.52]    [Pg.54]    [Pg.68]    [Pg.192]    [Pg.181]    [Pg.60]    [Pg.536]    [Pg.394]    [Pg.402]    [Pg.24]    [Pg.256]    [Pg.423]    [Pg.71]    [Pg.173]    [Pg.575]    [Pg.584]    [Pg.617]    [Pg.272]    [Pg.70]    [Pg.117]    [Pg.427]    [Pg.224]   
See also in sourсe #XX -- [ Pg.649 ]




SEARCH



Absolute refractive index detectors

Beam deflection refractive index detector

Chromatography refractive index detectors

Detector differential refractive index

Detectors refraction index

Detectors refractive index detector

Detectors, HPLC refractive index detector

Differential refractive index detectors detector values

Differential refractive index detectors values

Flow cells, detectors refractive index effects

HPLC detectors: refractive index

HPLC instrumentation refractive index detector

High-performance liquid chromatography refractive-index detectors

High-performance size exclusion refractive index detectors

INDEX Flame ionization detector

Lipids refractive index detector

Reflective index detectors

Refractive Index Detector (RID)

Refractive index detector

Refractive index detector Fresnel method

Refractive index detector applications

Refractive index detector response

Refractive index detector selection

Refractive index detectors branching distribution

Refractive index detectors detection

Refractive index detectors experimental conditions

Refractive index detectors fractionation

Refractive index detectors number-average molecular

Refractive index detectors reflection-type

Refractive index detectors refraction-type

Refractive index detectors response characteristics

Refractive index detectors universal calibration

Refractive index detectors weight

Refractive index, detector constant

Response index,detectors

Subject index detector

The refractive index detector

© 2024 chempedia.info