Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Density units

Changes in density, unit cell dimensions, and macroscopic volume have serious effects. In an environment where point defects (or aggregates of point defects) are generated, such as in the components of nuclear reactors, or in vessels used for the storage of nuclear waste, where point defects are produced as a result of irradiation, dimensional changes can cause components to seize or rupture. [Pg.16]

A concentrated Ca-D-pantothenate solution (1 mg/ml) is prepared in distilled water and dilutions made as needed. Refrigerated solutions are stable for 6 months. Pantothenate is added at 5, 10, 20, 40, 60, 80, and 100 mpg/ml final concentrations the control flask consists of basal medium alone for estimation of carry-over error—i.e., the pantothenate activity of the inoculum. The details of aseptic technique have been discussed elsewhere (H18, H19). Growth is measured in optical density units with a Welch Densichron, equipped with a red-sensitive probe to minimize blank readings due to the color of the medium. [Pg.198]

Growth measured in optical density units with a Welch Densichron. 6 Equal concentration of each total is twice the value given. [Pg.202]

The most common unit of kinematic viscosity is the centistokes (cS), the centipoise per density unit. Again, the base unit, the stokes (S) (100 cS/S), is seldom used. [Pg.420]

If specimen is also crystalline determine DENSITY, UNIT CELL and possible SPACE GROUPS. [Pg.319]

Flux density (units = particles area time )... [Pg.802]

The properties obtained by Fourier summation over AFobs or Fobs are those of the thermally averaged density. But because of the decreased dependence on the high-order reflections, the effect of thermal vibrations is not pronounced, especially for large volumes of integration. In other words, as long as a density unit vibrates harmonically within the volume of integration, neither the charge nor the dipole moment components will be affected. [Pg.154]

This is the most common form of data. The units of charge density, however, differ from paper to paper. Although the number of electrons per A- and per a.u. are commonly used, several authors use density units of electrons per unit cell or per atomic volume. [Pg.117]

So each liter of 15.0 M NHj contains 256 g of NHj solute. But how much mass does each liter of solution possess Calculate the mass of the solution by using the density. Note that the problem lists the density in units of milliliters, so be sure to convert to the proper units. To keep the calculations easy, we converted the liters of solution to milliliters to match the density units ... [Pg.180]

Species Density Unit cell size No. of molecules in unit Heat of formation — JHf kcal/mole... [Pg.170]

One optical density unit change is equivalent to 311.5 fig/ml cellular dry weight. Initial and final pHs are given at the beginning and end of each curve. [Pg.173]

Normally a stem or hydrometer is used to determine density. Hydrometers may be scaled in many different units. In the United States, grape juice and wine densities are usually measured in Brix or Balling degrees which are density units reflecting the weight per cent of sucrose in sucrose-water solutions. [Pg.292]

To see this, let us introduce some definitions first. The Poynting vector G represents energy flux density (units esu2cm-3 s-1 = ergcm2s 1). It is a capability of the electromagnetic field to perform work defined as... [Pg.349]

Two UV detectors are also available from Laboratory Data Control, the UV Monitor and the Duo Monitor. The UV Monitor (Fig.3.45) consists of an optical unit anda control unit. The optical unit contains the UV source (low-pressure mercury lamp), sample, reference cells and photodetector. The control unit is connected by cable to the optical unit and may be located at a distance of up to 25 ft. The dual quartz flow cells (path-length, 10 mm diameter, 1 mm) each have a capacity of 8 (i 1. Double-beam linear-absorbance measurements may be made at either 254 nm or 280 nm. The absorbance ranges vary from 0.01 to 0.64 optical density units full scale (ODFS). The minimum detectable absorbance (equivalent to the noise) is 0.001 optical density units (OD). The drift of the photometer is usually less than 0.002 OD/h. With this system, it is possible to monitor continuously and quantitatively the absorbance at 254 or 280 nm of one liquid stream or the differential absorbance between two streams. The absorbance readout is linear and is directly related to the concentration in accordance with Beer s law. In the 280 nm mode, the 254-nm light is converted by a phosphor into a band with a maximum at 280 nm. This light is then passed to a photodetector which is sensitized for a response at 280 nm. The Duo Monitor (Fig.3.46) is a dual-wavelength continuous-flow detector with which effluents can be monitored simultaneously at 254 nm and 280 nm. The system consists of two modules, and the principle of operation is based on a modification of the 280-nm conversion kit for the UV Monitor. Light of 254-nm wavelength from a low-pressure mercury lamp is partially converted by the phosphor into a band at 280 nm. [Pg.89]

Figure 2. Calibration curve for the Daresbury Optronics P-1000 microdensitometer by using Ilford Industrial G x-ray film. The figures above the data points indicate the nominal optical density of each measurement, assuming that a scanner reading of 255 corresponds to three optical density units. Figure 2. Calibration curve for the Daresbury Optronics P-1000 microdensitometer by using Ilford Industrial G x-ray film. The figures above the data points indicate the nominal optical density of each measurement, assuming that a scanner reading of 255 corresponds to three optical density units.
Note that the units of this rate constant are reciprocal concentration (in number density units) and reciprocal time (in s-1). Remember that number density is a fancy way of saying molecules per unit volume (usually as molecules/cm3). [Pg.56]

The total electron density is assumed to be a superposition of density units, each of which rigidly follows the motion of the nucleus that it is attached to. In terms of the scattering vector... [Pg.193]

The object is to partition the time of an individual predator. Let N denote the number of prey caught during a food-search time period of length T. Let x denote the prey density (units are cells/unit volume), s the search rate (units are volume/time), and b the handling time (units are time/prey). One then has N = sx(T-bN). The functional response (the consumption term) for one predator is N/T or, extending over a unit volume. [Pg.44]

Note Special density units called degrees Baume (°Be), degrees API (°API), and degrees Twaddell (°Tw) are occasionally used, particularly in the petroleum industry. Definitions of and conversion factors for these units are given on p. 1-20 of Perry s Chemical Engineers Handbook. [Pg.44]

Adsorption onto activated charcoal (Norit A) has been used for small oligonucleotides, up to tetranucleotides (Crane and Lipman 1953 Mandeles and Kammen 1966). The method is quicker and more convenient than DEAE-cellulose chromatography. Mandeles and Kammen (1966) used Norit A suspended in 1 mM phosphate 1 mM pyrophosphate buffer at pH 6.0 at a concentration of 100 mg/ml. The nucleotide solution is adjusted to pH 3 and 5 mg Norit for every optical density unit ( 40 pg) of nucleotides is added. The charcoal is collected on a filter paper and washed with water. (A good quantitative measure of or radio-activity may be obtained by counting the dry filter paper in a Geiger-Muller thin window counter.) The nucleotide material is eluted with a small volume of a mixture of ethanol, water and ammonia (600 400 6.5 v/v/v) which is then removed by drying under reduced pressure at 40°C. [Pg.297]

Sholkovitz (21) argued that it is difficult to separate the Mn and Fe redox cycles because dissolved Mn and Fe are well correlated in the suboxic zone. This theory is true to the extent that they both increase in the suboxic zone, but there is a clear difference in their distributions. The sharp increase in dissolved iron begins about 0.15 density units deeper than dissolved Mn (22, 23). [Pg.161]

Note The density values of these features, determined from the pump profile data, have a range of about 0.05 density units. [Pg.168]


See other pages where Density units is mentioned: [Pg.514]    [Pg.269]    [Pg.437]    [Pg.394]    [Pg.771]    [Pg.109]    [Pg.201]    [Pg.73]    [Pg.420]    [Pg.307]    [Pg.383]    [Pg.296]    [Pg.211]    [Pg.503]    [Pg.576]    [Pg.173]    [Pg.214]    [Pg.345]    [Pg.115]    [Pg.316]    [Pg.92]    [Pg.384]    [Pg.24]    [Pg.88]    [Pg.191]    [Pg.118]    [Pg.376]    [Pg.100]    [Pg.323]   
See also in sourсe #XX -- [ Pg.18 , Pg.21 ]

See also in sourсe #XX -- [ Pg.2 , Pg.8 ]

See also in sourсe #XX -- [ Pg.26 ]

See also in sourсe #XX -- [ Pg.2 , Pg.8 ]

See also in sourсe #XX -- [ Pg.455 ]

See also in sourсe #XX -- [ Pg.36 , Pg.341 , Pg.361 ]




SEARCH



Astronomical Unit density

Cell, unit density

Cell, unit number density

Cell, unit planar density

Crystal unit cell density

Density A property of matter representing the mass per unit volume

Density Mass per unit volume

Density atmospheric distillation unit

Density units of measurement

Flux densities, units

Hounsfield-unit density

Magnetic field flux density, units

Optical density units

Spectral density units

Unit cell: content, density

Units Volume and Density

Units current, 16 density

Valve unit density

© 2024 chempedia.info